Scatter correction for photon-counting detector based CBCT imaging

Objective: The aim of this study is to validate the effectiveness of an energy-modulated scatter correction method in suppressing scatter in photon-counting detector (PCD)-based cone beam CT (CBCT) imaging. Approach: The scatter correction method, named e-Grid, which was initially applied to dual-layer flat-panel detector (DLFPD)-based CBCT imaging, was tested for its performance in PCD-CBCT imaging. Benchtop PCD-CBCT imaging experiments were conducted to verify the effectiveness of the e-Grid method. Additionally, quantitative metrics were measured from these experimental results. Main results: It was found that the use of the e-Grid method could significantly eliminate cupping artifacts caused by Compton scatter in PCD-CBCT imaging. Meanwhile, its effectiveness was observed in both low- and high-energy images, as well as for objects of varying sizes. Quantitative results showed that the e-Grid method could reduce scatter artifacts by at least 71% in low-energy images and 75% in high-energy images. Significance: It was demonstrated that the scatter correction method originally applied to DLFPD-based CBCT could also perform well in PCD-CBCT, showing that the e-Grid method has great potential for application in other spectral CBCT imaging systems.

physics.med-ph↗

CBCT scatter correction with dual-layer flat-panel detector

Background: Recently, the popularity of dual-layer flat-panel detector (DL-FPD) based dual-energy cone-beam CT (DE-CBCT) imaging has been increasing. However, the image quality of DE-CBCT remains constrained by the Compton scattered X-ray photons. Purpose: The objective of this study is to develop an energy-modulated scatter correction method for DL-FPD based CBCT imaging. Methods: In DL-FPD, a certain portion of the X-ray photons (mainly low-energy primary and scattered photons) passing through the object are captured by the top detector layer, while the remaining X-ray photons (mainly high-energy primary and scattered photons) are collected by the bottom detector layer. Based on the two set of distinct low-energy and high-energy measurements, a linear signal model was approximated for the dual-energy primary and scattered signals on DL-FPD. The distributions of X-ray scatters were quickly estimated using this signal model. Monte Carlo (MC) simulation of a water phantom was conducted to verify this newly developed scatter estimation method. Moreover, physical experiments of water phantom, head phantom, and abdominal phantom were carried out to validate the real performance of this proposed scatter correction method. Results: The MC results showed that the e-Grid method was able to generate scatter distributions close to the ground truth. Moreover, the physical experiments demonstrated that the e-Grid method can greatly reduce the shading artifacts in both low-energy and high-energy CBCT images acquired from DL-FPD. On average, the image non-uniformity (NU) was reduced by over 77% in the low-energy CBCT image and by over 66% in the high-energy CBCT image. A a consequence, the accuracy of the decomposed multi-material bases was substantially improved.

physics.med-ph↗

Super resolution dual-layer CBCT imaging with model-guided deep learning

Objective: This study aims at investigating a novel super resolution CBCT imaging technique with the dual-layer flat panel detector (DL-FPD). Approach: In DL-FPD based CBCT imaging, the low-energy and high-energy projections acquired from the top and bottom detector layers contain intrinsically mismatched spatial information, from which super resolution CBCT images can be generated. To explain, a simple mathematical model is established according to the signal formation procedure in DL-FPD. Next, a dedicated recurrent neural network (RNN), named as suRi-Net, is designed by referring to the above imaging model to retrieve the high resolution dual-energy information. Different phantom experiments are conducted to validate the performance of this newly developed super resolution CBCT imaging method. Main Results: Results show that the proposed suRi-Net can retrieve high spatial resolution information accurately from the low-energy and high-energy projections having lower spatial resolution. Quantitatively, the spatial resolution of the reconstructed CBCT images of the top and bottom detector layers is increased by about 45% and 54%, respectively. Significance: In future, suRi-Net provides a new approach to achieve high spatial resolution dual-energy imaging in DL-FPD based CBCT systems.

physics.med-ph↗

Super resolution dual-energy cone-beam CT imaging with dual-layer flat-panel detector

For medical cone-beam computed tomography (CBCT) imaging, the native receptor array of the flat-panel detector (FPD) is usually binned into a reduced matrix size. By doing so, the signal readout speed can be increased by over 4-9 times at the expense of sacrificing the spatial resolution by at least 50%-67%. Clearly, such tradition poses a main bottleneck in generating high spatial resolution and high temporal resolution CBCT images at the same time. In addition, the conventional FPD is also difficult in generating dual-energy CBCT images. In this paper, we propose an innovative super resolution dual-energy CBCT imaging method, named as suRi, based on dual-layer FPD (DL-FPD) to overcome these aforementioned difficulties at once. With suRi, specifically, an 1D or 2D sub-pixel (half pixel in this study) shifted binning is applied to replace the conventionally aligned binning to double the spatial sampling rate during the dual-energy data acquisition. As a result, the suRi approach provides a new strategy to enable high signal readout speed and high spatial resolution CBCT imaging with FPD. Moreover, a penalized likelihood material decomposition algorithm is developed to directly reconstruct the high resolution bases from the dual-energy CBCT projections containing spatial sub-pixel shifts. Experiments based on the single-layer FPD and DL-FPD are performed with physical phantoms and biological specimen to validate this newly developed suRi method. The synthesized monochromatic CT imaging results demonstrate that suRi can significantly improve the spatial image resolution by 46.15%. We believe the developed suRi method would be capable to greatly enhance the imaging performance of the DL-FPD based dual-energy CBCT systems in future.

physics.med-ph↗

CMOS based high-resolution dynamic X-ray imaging with inorganic perovskite

High-resolution dynamic X-ray detector is crucial for time-resolved digital radiography (DR) imaging and fast 3D medical computed tomography (CT) imaging. Recently, perovskites have become promising alternatives to conventional semi-conductor materials, e.g., Si, a-Se and CdTe, for direct X-ray detection. However, the feasibility of their combination with high-speed pixelated complementary metal-oxide-semiconductor (CMOS) arrays remains unknown. This work originally reports an innovative direct-conversion X-ray detector fabricated with 300 micrometer thick inorganic perovskite film printed on a tailored CMOS array. In-house measurements demonstrate that the CsPbBr3 film has excellent optoelectric properties of an electron mobility-lifetime product of 3.40x10$^{-5}$ cm$^2$ V$^{-1}$, and the X-ray detector exhibits high sensitivity of 9341uC Gy$_{\rm air}^{-1}$ cm$^{-2}$, and low detection limit of 588 nGy$_{\rm air}^{-1}$. This CMOS X-ray imaging detector achieves a high spatial resolution up to 5.5 lp/mm (close to the resolution limit of 6.0 lp/mm), and >300 frame per second (fps) readout speed. DR image of a resolution pattern phantom and a anesthesia mice, CT images of a biological specimen are acquired for the first time.

physics.app-ph↗

Dual-domain Attention-based Deep Network for Sparse-view CT Artifact Reduction

Due to the wide applications of X-ray computed tomography (CT) in medical imaging activities, radiation exposure has become a major concern for public health. Sparse-view CT is a promising approach to reduce the radiation dose by down-sampling the total number of acquired projections. However, the CT images reconstructed by this sparse-view imaging approach suffer from severe streaking artifacts and structural information loss. In this work, an end-to-end dual-domain attention-based deep network (DDANet) is proposed to solve such an ill-posed CT image reconstruction problem. The image-domain CT image and the projection-domain sinogram are put into the two parallel sub-networks of the DDANet to independently extract the distinct high-level feature maps. In addition, a specified attention module is introduced to fuse the aforementioned dual-domain feature maps to allow complementary optimizations of removing the streaking artifacts and mitigating the loss of structure. Numerical simulations, anthropomorphic thorax phantom and in vivo pre-clinical experiments are conducted to verify the sparse-view CT imaging performance of the DDANet. Results demonstrate that this newly developed approach is able to robustly remove the streaking artifacts while maintaining the fine structures. As a result, the DDANet provides a promising solution in achieving high quality sparse-view CT imaging.

physics.med-ph↗

Automatic image-domain Moire artifact reduction method in grating-based x-ray interferometry imaging

The aim of this study is to demonstrate the feasibility of removing the image Moire artifacts caused by system inaccuracies in grating-based x-ray interferometry imaging system via convolutional neural network (CNN) technique. Instead of minimizing these inconsistencies between the acquired phase stepping data via certain optimized signal retrieval algorithms, our newly proposed CNN-based method reduces the Moire artifacts in the image-domain via a learned image post-processing procedure. To ease the training data preparations, we propose to synthesize them with numerical natural images and experimentally obtained Moire artifact-only-images. Moreover, a fast signal processing method has also been developed to generate the needed large number of high quality Moire artifact-only images from finite number of acquired experimental phase stepping data. Experimental results show that the CNN method is able to remove Moire artifacts effectively, while maintaining the signal accuracy and image resolution.

physics.med-ph↗