Dark Sectors and New, Light, Weakly-Coupled Particles

Dark sectors, consisting of new, light, weakly-coupled particles that do not interact with the known strong, weak, or electromagnetic forces, are a particularly compelling possibility for new physics. Nature may contain numerous dark sectors, each with their own beautiful structure, distinct particles, and forces. This review summarizes the physics motivation for dark sectors and the exciting opportunities for experimental exploration. It is the summary of the Intensity Frontier subgroup "New, Light, Weakly-coupled Particles" of the Community Summer Study 2013 (Snowmass). We discuss axions, which solve the strong CP problem and are an excellent dark matter candidate, and their generalization to axion-like particles. We also review dark photons and other dark-sector particles, including sub-GeV dark matter, which are theoretically natural, provide for dark matter candidates or new dark matter interactions, and could resolve outstanding puzzles in particle and astro-particle physics. In many cases, the exploration of dark sectors can proceed with existing facilities and comparatively modest experiments. A rich, diverse, and low-cost experimental program has been identified that has the potential for one or more game-changing discoveries. These physics opportunities should be vigorously pursued in the US and elsewhere.

hep-ph↗

Extremely Low Loss Phonon-Trapping Cryogenic Acoustic Cavities for Future Physical Experiments

Low loss Bulk Acoustic Wave devices are considered from the point of view of the solid state approach as phonon-confining cavities. We demonstrate effective design of such acoustic cavities with phonon-trapping techniques exhibiting extremely high quality factors for trapped longitudinally-polarized phonons of various wavelengths. Quality factors of observed modes exceed 1 billion, with a maximum $Q$-factor of 8 billion and $Q\times f$ product of $1.6\cdot10^{18}$ at liquid helium temperatures. Such high sensitivities allow analysis of intrinsic material losses in resonant phonon systems. Various mechanisms of phonon losses are discussed and estimated.

cond-mat.mes-hall↗

Observation of Rayleigh phonon scattering through excitation of extremely high overtones in low-loss cryogenic acoustic cavities for hybrid quantum systems

The confinement of high frequency phonons approaching 1 GHz is demonstrated in phonon-trapping acoustic cavities at cryogenic temperatures using a low-coupled network approach. The frequency range is extended by nearly an order of magnitude, with excitation at greater than the 200$^{\text{th}}$ overtone achieved for the first time. Such high frequency operation reveals Rayleigh-type phonon scattering losses due to highly diluted lattice impurities and corresponding glass-like behaviour, with a maximum $Q_L\times f$ product of $8.6\times 10^{17}$ at 3.8K and $4\times10^{17}$ at 15mK. This suggests a limit on the $Q\times f$ product due to unavoidable crystal disorder. Operation at 15 mK is high enough in frequency that the average phonon occupation number is less than unity, with a loaded quality factor above half a billion. This work represents significant progress towards the utilisation of such acoustic cavities for hybrid quantum systems.

cond-mat.mes-hall↗

Experimenting an optical second with strontium lattice clocks

Progress in realizing the SI second had multiple technological impacts and enabled to further constraint theoretical models in fundamental physics. Caesium microwave fountains, realizing best the second according to its current definition with a relative uncertainty of 2-4x10^(-16), have already been superseded by atomic clocks referenced to an optical transition, both more stable and more accurate. Are we ready for a new definition of the second? Here we present an important step in this direction: our system of five clocks connects with an unprecedented consistency the optical and the microwave worlds. For the first time, two state-of-the-art strontium optical lattice clocks are proven to agree within their accuracy budget, with a total uncertainty of 1.6x10^(-16). Their comparison with three independent caesium fountains shows a degree of reproducibility henceforth solely limited at the level of 3.1x10^(-16) by the best realizations of the microwave-defined second.

physics.atom-ph↗

Testing local position and fundamental constant invariance due to periodic gravitation and boost using long-term comparison of the SYRTE atomic fountains and H-masers

The frequencies of three separate Cs fountain clocks and one Rb fountain clock have been compared to various hydrogen masers to search for periodic changes correlated with the changing solar gravitational potential at the Earth and boost with respect to the Cosmic Microwave Background (CMB) rest frame. The data sets span over more than eight years. The main sources of long-term noise in such experiments are the offsets and linear drifts associated with the various H-masers. The drift can vary from nearly immeasurable to as high as 1.3*10^-15 per day. To circumvent these effects we apply a numerical derivative to the data, which significantly reduces the standard error when searching for periodic signals. We determine a standard error for the putative Local Position Invariance (LPI) coefficient with respect to gravity for a Cs-Fountain H-maser comparison of 4.8*10^-6 and 10^-5 for a Rb-Fountain H-maser comparison. From the same data the putative boost LPI coefficients were measured to a precision of up to parts in 10^11 with respect to the CMB rest frame. By combining these boost invariance experiments to a Cryogenic Sapphire Oscillator versus H-maser comparison, independent limits on all nine coefficients of the boost violation vector with respect to fundamental constant invariance (fine structure constant, electron mass and quark mass respectively), were determined to a precision of parts up to 10^10.

gr-qc↗

Demonstration of a Dual Alkali Rb/Cs Atomic Fountain Clock

We report the operation of a dual Rb/Cs atomic fountain clock. 133Cs and 87Rb atoms are cooled, launched, and detected simultaneously in LNE-SYRTE's FO2 double fountain. The dual clock operation occurs with no degradation of either the stability or the accuracy. We describe the key features for achieving such a simultaneous operation. We also report on the results of the first Rb/Cs frequency measurement campaign performed with FO2 in this dual atom clock configuration, including a new determination of the absolute 87Rb hyperfine frequency.

physics.atom-ph↗

Observation of persistent photoconductivity in bulk Gallium Arsenide and Gallium Phosphide samples at cryogenic temperatures using the Whispering Gallery mode method

Whispering Gallery modes in bulk cylindrical Gallium Arsenide and Gallium Phosphide samples have been examined both in darkness and under white light at cryogenics temperatures < 50 K. In both cases persistent photoconductivity was observed after initially exposing semiconductors to white light from a halogen lamp. Photoconductance decay time constants for GaP and GaAs were determined to be 0.900 +/- 0.081 ns and 1.098 +/- 0.063 ns, respectively, using this method.

physics.optics↗

Ultra-low noise microwave generation with fiber-based optical frequency comb and application to atomic fountain clock

We demonstrate the use of a fiber-based femtosecond laser locked onto an ultra-stable optical cavity to generate a low-noise microwave reference signal. Comparison with both a liquid Helium cryogenic sapphire oscillator (CSO) and a Ti:Sapphire-based optical frequency comb system exhibit a stability about $3\times10^{-15}$ between 1 s and 10 s. The microwave signal from the fiber system is used to perform Ramsey spectroscopy in a state-of-the-art Cesium fountain clock. The resulting clock system is compared to the CSO and exhibits a stability of $3.5\times10^{-14}τ^{-1/2}$. Our continuously operated fiber-based system therefore demonstrates its potential to replace the CSO for atomic clocks with high stability in both the optical and microwave domain, most particularly for operational primary frequency standards.

physics.atom-ph↗

Quantum Physics Exploring Gravity in the Outer Solar System: The Sagas Project

We summarise the scientific and technological aspects of the SAGAS (Search for Anomalous Gravitation using Atomic Sensors) project, submitted to ESA in June 2007 in response to the Cosmic Vision 2015-2025 call for proposals. The proposed mission aims at flying highly sensitive atomic sensors (optical clock, cold atom accelerometer, optical link) on a Solar System escape trajectory in the 2020 to 2030 time-frame. SAGAS has numerous science objectives in fundamental physics and Solar System science, for example numerous tests of general relativity and the exploration of the Kuiper belt. The combination of highly sensitive atomic sensors and of the laser link well adapted for large distances will allow measurements with unprecedented accuracy and on scales never reached before. We present the proposed mission in some detail, with particular emphasis on the science goals and associated measurements.

gr-qc↗

Cryogenic sapphire oscillator with exceptionally high long-term frequency stability

We report on the development of a sapphire cryogenic microwave resonator oscillator long-term fractional frequency stability of 2x10^-17Sqrt[τ] for integration times τ>10^3 s and negative drift of about 2.2x10^-15/day. The short-term frequency instability of the oscillator is highly reproducible and also state-of-the-art: 5.6x10^-16 for an integration time of τ~ 20 s.

physics.ins-det↗

Long Term Operation and Performance of Cryogenic Sapphire Oscillators

Cryogenic Sapphire Oscillators (CSO) developed at UWA have now been in operation around the world continuously for many years. Such oscillators, due to their excellent spectral purity are essential for interrogating atomic frequency standards at the limit of quantum projection noise; otherwise aliasing effects will dominate the frequency stability due to the periodic sampling between successive interrogations of the atomic transition. For this reason, UWA oscillators are now operational at NMI (Sydney), LNE-SYRTE (Paris), the French Space Agency (CNES, Toulouse) and at UWA (Perth). Other applications, which have attracted attention in recent years, include tests on fundamental principles of physics, such as tests of Lorentz invariance. This paper reports on the long-term operation and performance of such oscillators. We compare the long-term drift of some different CSOs. The drift rates turn out to be linear over many years and in the same direction. However, the magnitude seems to vary by more than one order of magnitude between the oscillators, ranging from 10^14 per day to a few parts in 10^13 per day.

physics.ins-det↗

Maser Oscillation in a Whispering-Gallery-Mode Microwave Resonator

We report the first observation of above-threshold maser oscillation in a whispering-gallery(WG)-mode resonator, whose quasi-transverse-magnetic, 17th azimuthal-order WG mode, at a frequency of approx. 12.038 GHz, with a loaded Q of several hundred million, is supported on a cylinder of mono-crystalline sapphire. An electron spin resonance (ESR) associated with Fe3+ ions, that are substitutively included within the sapphire at a concentration of a few parts per billion, coincides in frequency with that of the (considerably narrower) WG mode. By applying a c.w. `pump' to the resonator at a frequency of approx. 31.34 GHz, with no applied d.c. magnetic field, the WG (`signal') mode is energized through a three-level maser scheme. Preliminary measurements demonstrate a frequency stability (Allan deviation) of a few times 1e-14 for sampling intervals up to 100 s.

quant-ph↗

Astrophysical constraints on hypothetical variability of fundamental constants

(Abridged) Many-multiplet (MM) method applied to three inhomogeneous samples of Keck/HIRES quasar absorption spectra gives a shift in the value of the fine-structure constant of Delta alpha/alpha = (-5.4+/-1.2) 10^{-6} in the redshift range 0.2 < z < 3.7 (Murphy et al. 2003).The 1sigma error is, however, much too small and cannot be maintained by current observations of quasars. We present a modified MM method to set an upper limit on Delta alpha/alpha from a homogeneous sample of FeII lines identified in the up-to-date best quality VLT/UVES spectrum of HE 0515-4414. Our result is Delta alpha/alpha = (1.1+/-1.1) 10^{-5} at z = 1.149. Theoretical models of the fundamental physical interactions predict that the proton-to-electron mass ratio (mu = m_p/m_e) may relate to the shift in Delta alpha/alpha as Delta mu/mu = R Delta alpha/alpha. We use VLT/UVES high-resolution observations of molecular hydrogen H2 ultraviolet absorption lines at z = 3.025 toward Q 0347-3818 to bound the value of R. The obtained constraints on Delta ln mu = (2.1+/-3.6) 10^{-5} and on Delta ln alpha = (1.1+/-1.1) 10^{-5} rule out vary large values of |R| > 6.

astro-ph↗

Tests of Lorentz Invariance Using a Microwave Resonator: An Update

The frequencies of a cryogenic sapphire oscillator and a hydrogen maser are compared to set new constraints on a possible violation of Lorentz invariance. We determine the variation of the oscillator frequency as a function of its orientation (Michelson-Morley test) and of its velocity (Kennedy-Thorndike test) with respect to a preferred frame candidate. We constrain the corresponding parameters of the Mansouri and Sexl test theory to $δ- β+ 1/2 \leq 3.4 \times 10^{-9}$ and $β- α- 1 \leq 4.1 \times 10^{-7}$ which is of the same order as the best previous result for the former and represents a 50 fold improvement for the latter. These results correspond to an improvement of our previously published limits [Wolf P. et al., Phys. Rev. Lett. {\bf 90}, 6, 060402, (2003)] by about a factor 2. We describe the changes of the experiment, and show the new data that lead to that improvement.

gr-qc↗

Properties of a monolithic sapphire parametric transducer: prospects of measuring the standard quantum limit

To measure the standard quantum limit (SQL) a high quality transducer must be coupled to a high quality mechanical system. Due to its monolithic nature, the monolithic sapphire transducer (MST) has high quality factors for both types of resonances. Single loop suspension is shown to yield a mechanical quality factor of 6.10^8 at 4 K. From standard analysis we show the MST has the potential to measure noise fluctuations of the mechanical oscillator at the SQL. also, we point out a new way to determine if the transducer back action is quantum limited. We show that if the fluctuations are at the quantum limit, then the amplitude of the oscillation will be amplified by the ratio of the ringdown time to the measurement time, which is an inherently easier measurement.

gr-qc↗

Initial operation of the International Gravitational Event Collaboration

The International Gravitational Event Collaboration, IGEC, is a coordinated effort by research groups operating gravitational wave detectors working towards the detection of millisecond bursts of gravitational waves. Here we report on the current IGEC resonant bar observatory, its data analysis procedures, the main properties of the first exchanged data set. Even though the available data set is not complete, in the years 1997 and 1998 up to four detectors were operating simultaneously. Preliminary results are mentioned.

astro-ph↗