Searcharxiv⌕ Search

arXiv subjects

M. Wada

Publications and source records attributed to M. Wada.

At least 37 records · Page 2Linked to original sources

Properties of 187Ta revealed through isomeric decay

Mass-separated 187Ta in a high-spin isomeric state has been produced for the first time by multi-nucleon transfer reactions, employing an argon gas stopping cell and laser ionisation. Internal gamma rays revealed a 7.3 s isomer at 1778 keV, which decays through a rotational band with perturbations associated with the approach to a prolate-oblate shape transition. Model calculations show less influence from triaxiality compared to heavier elements in the same mass region. The isomer decay reduced E2 hindrance factor of 27 supports the interpretation that axial symmetry is approximately conserved.

nucl-ex↗

Accurately accounting for effects on times-of-flight caused by finite field-transition times during the ejection of ions from a storage trap: A study for TOF and MRTOF mass spectrometry

In applied forms of time-of-flight mass spectrometry utilizing ion storage devices prior to an analysis device, a non instantaneous electric ejection pulse applied in the region of ion storage is used to accelerate ions into the time-of-flight analyzer. The calculated mass value of the ions from the time-of-flight is dependent on the duration of the field transition up to full strength. For novel applications dedicated to precision measurements, such as multi-reflection time-of-flight mass spectrometry of short-lived isotopes, the goal is to continuously decrease the measurement uncertainty while providing a mass accuracy on the same order. Even though dynamic-field models for time-of-flight mass spectrometry have been considered in the past for technological advances, it is important to study the accuracy of the measured mass in this context. Using a simplified linear model for the field transition, we provide a basic investigation of the scenario, and discuss the deviation from the classical "mass-over-charge" dependency of the ions' time-of-flight, which becomes violated. The emerging mass discrepancy depends on the distance between the mass of the ion used for calibration and that of the ion of interest and, in extreme cases, can increase to about one percent for systems with short times-of-flight. However, for typical conditions in single-reference multi-reflection time-of-flight mass spectrometry, mass deviations caused by this effect typically remain below the 1 ppm level. If a mass calibration using two or more ion species is possible during the measurement, the effect becomes negligible for appropriate choices of reference masses.

physics.ins-det↗

High-stability, high-voltage power supplies for use with multi-reflection time-of-flight mass spectrographs

Achieving the highest possible mass resolving power in a multi-reflection time-of-flight mass spectrometer requires very high-stability power supplies. To this end, we have developed a programmable high-voltage power supply that can achieve long-term stability on the order of parts-per-million. Herein we present the design of the stable high-voltage system and bench-top stability measurements up to 1~kV; the stabilization technique can, in principle, be applied up to 15~kV or more.. We demonstrate that in the $\le$1~Hz band the output stability is on the level of 1~part per million (ppm) during one hour, with only slightly more output variation across 3 days. We further demonstrate that the output is largely free of noise in the 1~Hz -- 200~Hz band. We also demonstrate settling to the ppm level within one minute following a 100~V step transition. Finally, we demonstrate that when these power supplies are used to bias the electrodes of a multi-reflection time-of-flight mass spectrograph the measured time-of-flight is stable on the ppm-level for at least one hour.

physics.ins-det↗

Development of an "$α$-ToF" detector for correlated measurement of atomic masses and decay properties

We have developed a novel detector, referred to as an "$α$-ToF detector", for correlated measurements of atomic masses and decay properties of low-yield, short-lived radioactive isotopes using a multi-reflection time-of-flight mass spectrograph. By correlating measured time-of-flight signals with decay events, it will be possible to suppress background events and obtain accurate, high-precision mass values even in cases of very low event rates. An offline test of the $α$-ToF detector has shown that the time-of-flight detection efficiency for 5.48~MeV $α$-rays is more than 90\% and yields a time resolution of 251.5(68)~ps and an energy resolution of 141.1(9)~keV. Using a two-dimensional spectrum of the correlated $α$-ray energy and time-of-flight, the $α$-rays from mixed $α$ sources could be fairly well resolved.

physics.ins-det↗

The SABRE project and the SABRE PoP

SABRE aims to directly measure the annual modulation of the dark matter interaction rate with NaI(Tl) crystals. A modulation compatible with the standard hypothesis in which our Galaxy is embedded in a dark matter halo has been measured by the DAMA experiment in the same target material. Other direct detection experiments, using different target materials, seem to exclude the interpretation of such modulation in the simplest scenario of WIMP-nucleon elastic scattering. The SABRE experiment aims to carry out an independent search with sufficient sensitivity to confirm or refute the DAMA claim. The SABRE concept and goal is to obtain a background rate of the order of 0.1 cpd/kg/keVee in the energy region of interest. This challenging goal is achievable by operating high-purity crystals inside a liquid scintillator veto for active background rejection. In addition, twin detectors will be located in the northern and southern hemispheres to identify possible contributions to the modulation from seasonal or site-related effects. The SABRE project includes an initial Proof-of-Principle phase at LNGS (Italy), to assess the radio-purity of the crystals and the efficiency of the liquid scintillator veto. This paper describes the general concept of SABRE and the expected sensitivity to WIMP annual modulation.

physics.ins-det↗

Monte Carlo simulation of the SABRE PoP background

SABRE (Sodium-iodide with Active Background REjection) is a direct dark matter search experiment based on an array of radio-pure NaI(Tl) crystals surrounded by a liquid scintillator veto. Twin SABRE experiments in the Northern and Southern Hemispheres will differentiate a dark matter signal from seasonal and local effects. The experiment is currently in a Proof-of-Principle (PoP) phase, whose goal is to demonstrate that the background rate is low enough to carry out an independent search for a dark matter signal, with sufficient sensitivity to confirm or refute the DAMA result during the following full-scale experimental phase. The impact of background radiation from the detector materials and the experimental site needs to be carefully investigated, including both intrinsic and cosmogenically activated radioactivity. Based on the best knowledge of the most relevant sources of background, we have performed a detailed Monte Carlo study evaluating the expected background in the dark matter search spectral region. The simulation model described in this paper guides the design of the full-scale experiment and will be fundamental for the interpretation of the measured background and hence for the extraction of a possible dark matter signal.

physics.ins-det↗

New mass anchor points for neutron-deficient heavy nuclei from direct mass measurements of radium and actinium isotopes

The masses of the exotic isotopes $^{210-214}$Ac and $^{210-214}$Ra have been measured with a multi-reflection time-of-flight mass spectrograph. These isotopes were obtained in flight as fusion-evaporation products behind the gas-filled recoil ion separator GARIS-II at RIKEN. The new direct mass measurements serve as an independent and direct benchmark for existing $α$-$γ$ spectroscopy data in this mass region. Further, new mass anchor points are set for U and Np nuclei close to the $N=126$ shell closure for a future benchmark of the $Z=92$ sub-shell for neutron-deficient heavy isotopes. Our mass results are in general in good agreement with the previously indirectly-determined mass values. Together with the measurement data, reasons for possible mass ambiguities from decay-data links between ground states are discussed.

nucl-ex↗

Improving wide-band mass measurements in a multi-reflection time-of-flight mass spectrograph by usage of a concomitant measurement scheme

We introduce a new concomitant referencing mode for operating a multi-reflection time-of-flight mass spectrograph (MRTOF-MS), wherein the reference and analyte ions are interleaved on a cycle by cycle bases. Using this mode, we demonstrate an improved technique for performing wide bandwidth mass measurements via MRTOF-MS. This new technique offers a simplified analysis and high-accuracy.

physics.ins-det↗

First direct mass measurements of nuclides around $Z=100$ with a Multireflection Time-of-Flight Mass Spectrograph

The masses of $^{246}$Es, $^{251}$Fm and the transfermium nuclei $^{249-252}$Md, and $^{254}$No, produced by hot- and cold-fusion reactions, in the vicinity of the deformed $N=152$ neutron shell closure, have been directly measured using a multireflection time-of-flight mass spectrograph. The masses of $^{246}$Es and $^{249,250,252}$Md were measured for the first time. Using the masses of $^{249,250}$Md as anchor points for $α$ decay chains, the masses of heavier nuclei, up to $^{261}$Bh and $^{266}$Mt, were determined. These new masses were compared with theoretical global mass models and demonstrated to be in good agreement with macroscopic-microscopic models in this region. The empirical shell gap parameter $δ_{2n}$ derived from three isotopic masses was updated with the new masses and corroborate the existence of the deformed $N=152$ neutron shell closure for Md and Lr.

nucl-ex↗

Atomic masses of intermediate-mass neutron-deficient nuclei with relative uncertainty down to 35-ppb via multireflection time-of-flight mass spectrograph

High-precision mass measurements of $^{63}$Cu, $^{64-66}$Zn, $^{65}$Ga, $^{65-67}$Ge, $^{67}$As, $^{78,81}$Br, $^{80}$Rb, and $^{79}$Sr were performed utilizing a multireflection time-of-flight mass spectrograph combined with the gas-filled recoil ion separator GARIS-II. In the case of $^{65}$Ga, a mass uncertainty of 2.1 keV, corresponding to a relative precision of $δm / m = 3.5\times10^{-8}$, was obtained and the mass value is in excellent agreement with the 2016 Atomic Mass Evaluation. For $^{67}$Ge and $^{81}$Br, where masses were previously deduced through indirect measurements, discrepancies with literature values were found. The feasibility of using this device for mass measurements of nuclides more neutron-deficient side, which have significant impact on the $rp$-process pathway, is discussed.

nucl-ex↗

In-gas-cell laser spectroscopy for magnetic dipole moment of $^{199}$Pt toward $N=$ 126

Magnetic dipole moment and mean-square charge radius of $^{199}$Pt ($I^π=$ 5/2$^-$) have been evaluated for the first time from the investigation of the hyperfine splitting of the $λ_1=$ 248.792 nm transition by in-gas-cell laser ionization spectroscopy. Neutron-rich nucleus $^{199}$Pt was produced by multi-nucleon transfer reaction at the KISS where the nuclear spectroscopy in the vicinity of $N=$ 126 is planed from the aspect of an astrophysical interest as well as the nuclear structure. Measured magnetic dipole moment $+$0.63(13)$μ_{\rm N}$ is consistent with the systematics of those of nuclei with $I^π=$ 5/2$^-$. The deformation parameter $|<β_2^2>^{1/2}|$ evaluated from the isotope shift indicates the gradual shape change to spherical shape of platinum isotopes with increasing neutron number toward $N=$ 126.

nucl-ex↗

First Online Mass Measurements of Isobar Chains via Multi-Reflection Time-of-Flight Mass Spectrograph Coupled with GARIS-II

Using a mulit-reflection time-of-flight mass spectrograph (MRTOF-MS) located after a gas cell coupled with the gas-filled recoil ion separator GARIS-II, the masses of several heavy nuclei have been directly and precisely measured. The nuclei were produced via fusion-evaporation reactions and separated from projectile-like and target-like particles using GARIS-II before being stopped in a helium-filled gas cell. Time-of-flight spectra for three isobar chains, 205Fr-205Rn-205At-205Po, 206Fr-206Rn-206At and 201Rn-201At-201Po-201Bi, were observed. Precision atomic mass values were determined for 205,206Fr, 201At, and 201Po.

nucl-ex↗

A novel ion cooling trap for multi-reflection time-of-flight mass spectrograph

A radiofrequency quadrupole ion trap system for use with a multi-reflection time-of-flight mass spectrograph (MRTOF) for short-lived nuclei has been developed. The trap system consists of two different parts, an asymmetric taper trap and a flat trap. The ions are cooled to a sufficient small bunch for precise mass measurement with MRTOF in only 2 ms cooling time in the flat trap, then orthogonally ejected to the MRTOF for mass analysis. A trapping efficiency of ~27% for 23Na+ and ~5.1% for 7Li+ has been achieved.

physics.ins-det↗

Single-reference high-precision mass measurement with a multi-reflection time-of-flight mass spectrograph

A multi-reflection time-of-flight mass spectrograph, competitive with Penning trap mass spectrometers, has been built at RIKEN. We have performed a first online mass measurement, using 8Li+ (T1/2 = 838 ms). A new analysis method has been realized, with which, using only 12C+ references, the mass excess of 8Li was accurately determined to be 20947.6(15)(34) keV (dm/m = 6.6 x 10-7). The speed, precision and accuracy of this first online measurement exemplifies the potential for using this new type of mass spectrograph for precision measurements of short-lived nuclei.

nucl-ex↗

An rf-carpet electrospray ion source to provide isobaric mass calibrants for trans-uranium elements

For trans-uranium elements, stable atomic isobars do not exist. In order to provide isobaric reference ions for the mass measurement of trans-uranium elements, an electrospray ion source (ESI) was combined with an rf-carpet to collect molecular ions efficiently. The rf-carpet allows for simplification of the pumping system to transport ions from the ESI to a precision mass analyzer. Molecular ions appropriate for isobaric references of trans-uranium elements were extracted from the rf-carpet and analyzed by a multi-reflection time-of-flight mass spectrograph (MRTOF-MS) with a resolving power of $\rm{R_m} \gtrsim100,000$.

nucl-ex↗

Development of a resonant laser ionization gas cell for high-energy, short-lived nuclei

A new laser ion source configuration based on resonant photoionization in a gas cell has been developed at RIBF RIKEN. This system is intended for the future PArasitic RI-beam production by Laser Ion-Source (PALIS) project which will be installed at RIKEN's fragment separator, BigRIPS. A novel implementation of differential pumping, in combination with a sextupole ion beam guide (SPIG), has been developed. A few small scroll pumps create a pressure difference from 1000 hPa - 10^-3 Pa within a geometry drastically miniaturized compared to conventional systems. This system can utilize a large exit hole for fast evacuation times, minimizing the decay loss for short-lived nuclei during extraction from a buffer gas cell, while sufficient gas cell pressure is maintained for stopping high energy RI-beams. In spite of the motion in a dense pressure gradient, the photo-ionized ions inside the gas cell are ejected with an assisting force gas jet and successfully transported to a high-vacuum region via SPIG followed by a quadrupole mass separator. Observed behaviors agree with the results of gas flow and Monte Carlo simulations.

physics.ins-det↗

Well-localized edge states in two-dimensional topological insulators: ultrathin Bi films

We theoretically study the generic behavior of the penetration depth of the edge states in two-dimensional quantum spin Hall systems. We found that the momentum-space width of the edge-state dispersion scales with the inverse of the penetration depth. As an example of well-localized edge states, we take the Bi(111) ultrathin film. Its edge states are found to extend almost over the whole Brillouin zone. Correspondingly, the bismuth (111) 1-bilayer system is proposed to have well-localized edge states in contrast to the HgTe quantum well.

cond-mat.mtrl-sci↗