SearcharxivSearch

arXiv subjects

Markku Vainio

Publications and source records attributed to Markku Vainio.

At least 19 recordsLinked to original sources

Roadmap: Emerging Platforms and Applications of Optical Frequency Combs and Dissipative Solitons

The discovery of optical frequency combs (OFCs) has revolutionised science and technology by bridging electronics and photonics, driving major advances in precision measurements, atomic clocks, spectroscopy, telecommunications, and astronomy. However, current OFC systems still require further development to enable broader adoption in fields such as communication, aerospace, defence, and healthcare. There is a growing need for compact, portable OFCs that deliver high output power, robust self-referencing, and application-specific spectral coverage. On the conceptual side, progress toward such systems is hindered by an incomplete understanding of the fundamental principles governing OFC generation in emerging devices and materials, as well as evolving insights into the interplay between soliton and mode-locking effects. This roadmap presents the vision of a diverse group of academic and industry researchers and educators from Europe, along with their collaborators, on the current status and future directions of OFC science. It highlights a multidisciplinary approach that integrates novel physics, engineering innovation, and advanced researcher training. Topics include advances in soliton science as it relates to OFCs, the extension of OFC spectra into the visible and mid-infrared ranges, metrology applications and noise performance of integrated OFC sources, new fibre-based OFC modules, OFC lasers and OFC applications in astronomy.

physics.optics

Reference-free dual-comb spectroscopy with inbuilt coherence

We demonstrate a simple system for dual-comb spectroscopy based on two inherently coherent optical frequency combs generated via seeded parametric down-conversion. The inbuilt coherence is established by making the two combs share a common comb line. We show that the inbuilt coherence makes it possible to use a simple numerical post-processing procedure to compensate for small drifts of the dual-comb interferogram arrival-time and phase. This enables long-time coherent averaging of the interferograms.

physics.optics

Vortex-comb spectroscopy

We propose a new Fourier-transform spectroscopy technique based on the rotational Doppler effect. The technique offers an application for optical vortex frequency combs, where each frequency component carries a unique amount of orbital angular momentum (OAM). Here, we emulate a vortex comb using a tunable single frequency laser and a collection of spiral phase plates, generating up to eleven distinct OAM modes. Unlike in traditional Fourier-transform spectroscopy based on the Michelson interferometer (linear Doppler effect), the spectral resolution of vortex-comb spectroscopy is not limited by the mechanical scan distance of the instrument but only by the measurement time. Although the spectrometer requires just one free-running frequency comb, the down-conversion scheme resembles dual-comb spectroscopy, leading to fast mode-resolved measurements.

physics.optics

Photoacoustic phase-controlled Fourier-transform infrared spectroscopy

We demonstrate a 13-fold speed improvement in broadband cantilever-enhanced photoacoustic spectroscopy (CEPAS) by combining it with phase-controlled Fourier-transform spectroscopy (PC-FTS) instead of traditional Fourier-transform infrared spectroscopy (FTIR). PC-FTS is a modification of FTIR and capable of fundamentally faster interferogram acquisitions. The speed-improvement is beneficial for CEPAS, which is an especially sensitive version of the background-free photoacoustic spectroscopy technique. We used the PC-FTS-CEPAS technique to measure the absorption spectrum of methane in the mid-infrared region (3.3$-$3.5 $μ$m) with an optical frequency comb as the light source.

physics.optics

Versatile optical frequency combs based on multi-seeded femtosecond optical parametric generation

This study proposes and demonstrates a versatile method for near and mid-infrared optical frequency comb generation using multi-seeded femtosecond optical parametric generation. The method allows one to divide the repetition rate by an arbitrarily large integer factor, freely tune the offset frequency, and adjust the common phase offset of the comb modes. Since all possible degrees of freedom are adjustable, the proposed method manifests itself as versatile optical frequency synthesis.

physics.optics

Infrared spectroscopy of radioactive hydrogen chloride H$^{36}\!$Cl

We present the first report of optical absorption spectroscopy of H$^{36}\!$Cl, a radioactive isotopologue of hydrogen chloride. We used Fourier-transform infrared spectroscopy to determine the line center wavenumbers of the fundamental rovibrational band lines P(10)-R(10) and the first overtone band lines P(1)-R(7) with total uncertainty of less than 0.0018 cm$^{-1}$ (60 MHz) and 0.007 cm$^{-1}$ (0.2 GHz), respectively, at 68 % confidence level. We also performed a rotational analysis on the bands to determine the related molecular constants. We further compared the linewidths and relative intensities of the lines to those of the stable isotopologues H$^{35}\!$Cl and H$^{37}\!$Cl. The new spectroscopic information assists in developing optical instrumentation for the detection of H$^{36}\!$Cl.

physics.chem-ph

Mid-infrared frequency comb with 25 pJ threshold via CW-seeded optical parametric generation in nonlinear waveguide

We demonstrate efficient generation of mid-infrared frequency combs based on continuous-wave-seeded femtosecond optical parametric generation in nonlinear waveguides. Conversion of the near-infrared pump to signal and idler light takes place with very high efficiency (74 %) and the threshold (25 pJ) is over 300 times lower than in bulk analogs. Relative intensity noise of the mid-infrared comb is exceptionally low, below 5*10-5 (detector-limited, integrated from 10 Hz to 2 MHz). Furthermore, the mid-infrared bandwidth can be increased by driving the process with broadband pump obtained via supercontinuum generation.

physics.optics

Cantilever-enhanced photoacoustic measurement of light-absorbing aerosols

Photoacoustic detection is a sensitive method for measurement of light-absorbing particles directly in the aerosol phase. In this article, we demonstrate a new sensitive technique for photoacoustic aerosol absorption measurements using a cantilever microphone for the detection of the photoacoustic signal. Compared to conventional diaphragm microphones, a cantilever offers increased sensitivity by up to two orders of magnitude. Here we reached a noise level of 0.013 Mm$^{-1}$ (one standard deviation) with a sampling time of 20 s, using a simple single-pass design without a need for a resonant acoustic cell. We demonstrate the method in measurements of size-selected nigrosin particles and ambient black carbon. Due to the exceptional sensitivity, the technique shows great potential for applications where low detection limits are required, for example size-selected absorption measurements and black carbon detection in ultra clean environments.

physics.ins-det

LED based photoacoustic NO$_2$ sensor with sub-ppb detection limit

A high-sensitivity LED based photoacoustic NO$_2$ sensor is demonstrated. Sensitive photoacoustic gas sensors based on incoherent light sources are typically limited by background noise and drifts due to a strong signal generated by light absorbed at the photoacoustic cell walls. Here we reach a sub-ppb detection limit and excellent stability by using cantilever-enhanced photoacoustic detection and performing a two-channel relative measurement. A white-light LED is used as a light source and the spectrum is divided into two wavelength channels with a dichroic filter. The photoacoustic signals generated by the two wavelength channels are measured simultaneously and used to solve the NO$_2$ concentration. The background signal is highly correlated between the two channels and its variations are suppressed in the relative measurement. A noise level below 1 ppb is reached with an averaging time of 70 s. This is, to the best of our knowledge, the first time a sub-ppb detection limit is demonstrated with an LED based photoacoustic NO$_2$ sensor. As LEDs are available at wide selection of emission wavelengths, the results show great potential for development of cost-effective and sensitive detectors for a variety of other trace gasses as well.

physics.ins-det

Optical power detector with broad spectral coverage, high detectivity and large dynamic range

Optical power measurements are needed in practically all technologies based on light. Here we report a general-purpose optical power detector based on the photoacoustic effect. Optical power incident on the detector's black absorber produces an acoustic signal, which is further converted into an electrical signal using a silicon-cantilever pressure transducer. We demonstrate an exceptionally large spectral coverage from ultraviolet to far infrared, with the possibility for further extension to the terahertz region. The linear dynamic range of the detector reaches 80 dB, ranging from a noise-equivalent power of 6 nW to 600 mW.

physics.optics

Electromagnetic Radiation Detection with Broad Spectral Sensitivity and Large Dynamic Range using Cantilever-based Photoacoustic Effect

A sensitive photoacoustic detection approach employing a silicon cantilever is investigated for power measurement of electromagnetic radiation. The technique which is actuated by pressure waves generated through radiation-induced heat, depicts high sensitivity for a considerably large spectral range from 325 nm to 1523 nm. The implemented method shows linear response in the measurement of radiation power from 15 nW to 6 mW, demonstrating a dynamic range of almost six orders of magnitude. A numerical model has been developed to analyse and optimise the measurement sensitivity using different dimensions of the cantilever which is one of the key components of the detection process. The numerical results are in good agreement with the experimentally obtained frequency response of the detection process. The power detection technique shows potential of finding future applications in the technologies that employ electromagnetic radiation detection for scientific studies and industrial purposes.

physics.ins-det

Simple method for mid-infrared optical frequency comb generation with dynamic offset frequency tuning

We present a simple method for fully-stabilized mid-infrared optical frequency comb generation based on single-pass femtosecond optical parametric generation that is seeded by a continuous-wave laser. We have implemented the method in a periodically poled lithium niobate crystal that produces a frequency comb tunable across 3325 - 4000 nm (2380 - 3030 cm-1). The method generates the mid-infrared (idler) comb with known and stabilized Carrier-Envelope Offset (CEO) frequency without the need to directly detect it. The idler CEO is continuously tunable for almost half of the repetition rate and can be modulated, while maintaining its central frequency. Together with the high output power (up to 700 mW) and low intensity noise (0.018% integrated in 10 Hz - 2 MHz bandwidth) this makes the demonstrated mid-infrared frequency comb promising for many applications such as high-precision molecular spectroscopy, frequency metrology and high harmonic generation.

physics.optics

Photoacoustic characteristics of carbon-based infrared absorbers

We present an experimental comparison of photoacoustic responsivities of common highly absorbing carbon-based materials. The comparison was carried out with parameters relevant for photoacoustic power detectors and Fourier-transform infrared (FTIR) spectroscopy: we covered a broad wavelength range from the visible red to far infrared (633 nm to 25 um) and the regime of low acoustic frequencies (< 1 kHz). The investigated materials include a candle soot-based coating, a black paint coating and two different carbon nanotube coatings. Of these, the low-cost soot absorber produced clearly the highest photoacoustic response over the entire measurement range.

physics.ins-det

Experimental study of the effect of phase mismatch on a CW-pumped cascaded quadratic nonlinear frequency comb

Optical frequency comb generation by continuous-wave-pumped cascaded quadratic nonlinearities (CQN) appears a promising alternative to well-established modelocked lasers, especially if access to the mid-infrared spectral region is needed. We report an experimental investigation of spectral properties of a CQN frequency comb, which is based on second-harmonic generation (SHG) and is pumped internally by a continuous-wave optical parametric oscillator. Our study focuses on SHG phase mismatch, which has drawn little attention in the previously reported CQN frequency comb research. The main observation of our study is that it is possible to improve spectral purity of the CQN frequency comb by adjusting the phase mismatch. In addition to the CQN process that generates a frequency comb in the near-infrared region, our experimental setup involves several other nonlinear processes. These processes lead to a composite comb, which extends from visible to mid-infrared.

physics.optics

High-resolution analysis of the ${ν_3}$ band of radiocarbon methane $^{14}CH_{4}$

We present the first high-resolution measurements and rotational analysis of the fundamental asymmetric stretching vibrational band ${ν_3}(F_2)$ of radiocarbon methane. A spectrometer consisting of a mid-infrared continuous-wave optical parametric oscillator and a cantilever-enhanced photoacoustic detector was employed to determine the wavenumbers of 43 rovibrational lines. A spectroscopic model could reproduce all the observed transition wavenumbers within the accuracy of the experiment. Our work contributes to the development of radiocarbon methane detectors based on laser spectroscopy.

physics.chem-ph

Broadband photoacoustic spectroscopy of $^{14}\text{CH}_4$ with a high-power mid-infrared optical frequency comb

We report a photoacoustic spectroscopy setup with a high-power mid-infrared frequency comb as the light source. The setup is used in broadband spectroscopy of radiocarbon methane. Due to the high sensitivity of a cantilever-enhanced photoacoustic cell and the high power light source, we can reach a detection limit below 100 ppb in a broadband measurement with a sample volume of only a few milliliters. The first infrared spectrum of $^{14}\text{CH}_4$ is reported and given a preliminary assignment. The results lay a foundation for the development of optical detection systems for radiocarbon methane.

physics.optics

Towards optical frequency comb generation in continuous-wave pumped titanium indiffused lithium niobate waveguide resonators

Much progress, both experimentally and theoretically, has recently been made towards optical frequency comb generation from continuously pumped second-order nonlinear systems. Here, we present the first observations towards finding an integrated solution for such a system, using a titanium indiffused lithium niobate waveguide resonator. These results are compared to recently developed theory for equivalent systems. The system is seen to exhibit strong instabilities, which require further investigation in order to fully determine the suitability of this platform for stable optical frequency comb generation.

physics.optics

Optical frequency comb photoacoustic spectroscopy

We report the first photoacoustic detection scheme using an optical frequency comb - the optical frequency comb photoacoustic spectroscopy (OFC-PAS). OFC-PAS combines the broad spectral coverage and the high resolution of OFCs with the small sample volume of cantilever-enhanced PA detection. In OFC-PAS, a Fourier transform spectrometer (FTS) is used to modulate the intensity of the exciting comb source at a frequency determined by its scanning speed. One of the FTS outputs is directed to the PA cell and the other is measured simultaneously with a photodiode and used to normalize the PA signal. The cantilever-enhanced PA detector operates in a non-resonant mode, enabling detection of broadband frequency response. The broadband and the high-resolution capabilities of OFC-PAS are demonstrated by measuring the rovibrational spectra of the fundamental C-H stretch band of CH${_4}$, with no instrumental line shape distortions, at total pressures of 1000 mbar, 650 mbar, and 400 mbar. In this first demonstration, a spectral resolution two orders of magnitude higher than previously reported with broadband PAS is obtained, limited by the pressure broadening. A limit of detection of 0.8 ppm of methane in N${_2}$ is accomplished in a single interferogram measurement (200 s measurement time, 1000 MHz resolution, 1000 mbar total pressure) for an exciting power spectral density of 42 μW/cm${^{-1}}$. A normalized noise equivalent absorption of 8x10${^{-10}}$ W cm${^{-1}}$ Hz${^{-1/2}}$ is obtained, which is only a factor of three higher than the best reported with PAS based on continuous wave lasers. A wide dynamic range of up to four orders of magnitude and a very good linearity (limited by the Beer-Lambert law) over two orders of magnitude are realized. OFC-PAS extends the capability of optical sensors for multispecies trace gas analysis in small sample volume with high resolution and selectivity.

physics.optics