SearcharxivSearch

arXiv subjects

N. Kuroda

Publications and source records attributed to N. Kuroda.

At least 19 recordsLinked to original sources

Monitoring antiproton numbers with a CMOS detector in a dense-track environment

The production of antihydrogen by the GBAR experiment at AD/ELENA requires good knowledge of the number of incident keV antiprotons, which can be problematic. We have used a commercial CMOS digital camera mounted around the experimental vacuum chamber to determine antiproton numbers from ionising particles created in the annihilation process on the surface of microchannel plate detectors which are used for beam imaging. We show that the multiplicity of emerging charged particles is as expected for individual annihilations of antiprotons with nucleons at rest, taking into account the surrounding material budget. Most of those particles are in the minimal ionising regime, but can be detected with nearly 100% efficiency in the CMOS pixel detector, while due to the thin depletion layer the device is insensitive to background gammas. Thanks to the high granularity and small pixel size millions of antiproton annihilations can be reconstructed in a dense tracking environment over a large dynamic range with good resolution. From cluster length studies of non perpendicular tracks the thickness of the depletion zone and effective detection area was estimated. The cluster length also allows for a monitoring of track angles. Antiproton numbers are determined from the number of reconstructed clusters in the CMOS sensor by means of the covered solid angle relative to a calibration measurements with well known beam intensities at the most upstream location of the GBAR apparatus. Material effects on the emerging annihilation products were estimated by Monte Carlo (Geant4) calculations, while annihilation artefacts on the complex surface of a microchannel plate are cancelled out in this approach. This method minimises largely systematic uncertainties, leading to a final error of roughly 10% for the reconstruction of absolute antiproton numbers.

physics.ins-det

A determination of the backscattering probability of low-energy antiprotons

It is commonly assumed that antiprotons impinging on a material surface annihilate promptly with the nuclei of the material. However, at kinetic energies of a few keV, this assumption may not hold. As with low-energy protons, electrons or positrons that can be reflected from a target, they may undergo large-angle Coulomb scattering before annihilation occurs, thereby appearing to be "backscattered" from the material surface. This backscattering fraction, largely unknown, is a crucial ingredient to the determination of the production cross-section of antihydrogen atoms in the GBAR experiment. This paper presents a determination of the probability that 4 and 6 keV antiprotons backscatter on the surface of a Micro-Channel Plate detector used for beam imaging at GBAR. No evidence for backscattering has been found and an upper limit of 14% at 68% confidence level has been set on this probability. The impact of backscattering on the determination of the number of antiprotons that participate in antihydrogen production in GBAR is also addressed.

hep-ex

Record accumulation of antiprotons in a Penning-Malmberg Trap and their preparation for improved production of antihydrogen beams

CERN's AD/ELENA ``antimatter factory'' - unique worldwide - serves several experiments, all of which use electromagnetic traps to accumulate antiprotons for fundamental science. The GBAR experiment employs a charge-exchange reaction between an antiproton beam and a positronium cloud to produce antihydrogen for gravitational studies. GBAR has also pioneered an electrostatic scheme using a pulsed drift tube to decelerate the 100 keV antiproton beam, rather than slowing the antiprotons in a foil, as is commonly done in other experiments. Following first results producing a 6 keV antihydrogen beam directly after the decelerator, a trap has now been installed to increase the production rate. The emittance growth resulting from the deceleration is reduced in the trap by Coulomb interaction with a cold electron cloud. The antiproton cloud is further compressed using rotating wall cooling and can be re-accelerated up to energies of 10 keV, including a time focus. Here we describe the commissioning results, trapping 56(3)\% of the ELENA beam, delivering $6.4(0.4)~\times~10^{6}$ antiprotons per shot for improved production of antihydrogen, and a record accumulation of over $6.4(0.4)~\times~10^{7}$ antiprotons in under 35 minutes.

hep-ex

Measured Properties of an Antihydrogen Beam

We report a factor of $100$ increase in the antihydrogen beam intensity downstream of ASACUSA's Cusp trap: $320$ atoms detected per $15$-minute run. The beam contains many Rydberg atoms, which we selectively ionize to determine their velocity and binding energy. The time of flight signal is modeled using a $1\mathrm{D}$ Maxwellian velocity distribution with a temperature of $1500\,\mathrm{K}$, which is close to the measured antiproton plasma temperature. A numerical simulation reproduces the observed distribution of binding energies and suggests that about $16\%$ of the atoms may be in the ground state.

physics.ins-det

The CCOR Compact Coronagraphs for the Geostationary Operational Environmental Satellite-19 (GOES-19) and the Space Weather Follow On (SWFO) Missions

The CCOR Compact Coronagraph is a series of two operational solar coronagraphs sponsored by the National Oceanic and Atmospheric Administration (NOAA). They were designed, built, and tested by the U.S. Naval Research Laboratory (NRL). The CCORs will be used by NOAA's Space Weather Prediction Center to detect and track Coronal Mass Ejections (CMEs) and predict the Space Weather. CCOR-1 is on board the Geostationary Operational Environmental Satellite -U (GOES-U, now GOES-19/GOES-East). GOES-U was launched from Kennedy Space Flight Center, Florida, on 25 June 2024. CCOR-2 is on board the Space Weather Follow On at Lagrange point 1 (SWFO-L1). SWFO-L1 is scheduled to launch in the fall of 2025. SWFO will be renamed SOLAR-1 once it reaches L1. The CCORs are white-light coronagraphs that have a field of view and performance similar to the SOHO LASCO C3 coronagraph. CCOR-1 FOV spans from 4 to 22 Rsun, while CCOR-2 spans from 3.5 to 26 Rsun. The spatial resolution is 39 arcsec for CCOR-1 and 65 arcsec for CCOR-2. They both operate in a band-pass of 470 - 740 nm. The synoptic cadence is 15 min and the latency from image capture to the forecaster on the ground is less than 30 min. Compared to past generation coronagraphs such as the Large Angle and Spectrometric Coronagraph (LASCO), CCOR uses a compact design; all the solar occultation is done with a single multi-disk external occulter. No internal occulter is used. This allowed a substantial reduction in size and mass compared to SECCHI COR-2, for example, but with slightly lower signal-to-noise ratio. In this article, we review the science that the CCORs will capitalize on for the purpose of operational space weather prediction. We give a description of the driving requirements and accommodations, and provide details on the instrument design. In the end, information on ground processing and data levels is provided.

astro-ph.IM

Injection and capture of antiprotons in a Penning-Malmberg trap using a drift tube accelerator and degrader foil

The Antiproton Decelerator (AD) at CERN provides antiproton bunches with a kinetic energy of 5.3 MeV. The Extra-Low ENergy Antiproton ring at CERN, commissioned at the AD in 2018, now supplies a bunch of electron-cooled antiprotons at a fixed energy of 100 keV. The MUSASHI antiproton trap was upgraded by replacing the radio-frequency quadrupole decelerator with a pulsed drift tube to re-accelerate antiprotons and optimize the injection energy into the degrader foils. By increasing the beam energy to 119 keV, a cooled antiproton accumulation efficiency of (26 +- 6)% was achieved.

physics.acc-ph

Upgrade of the positron system of the ASACUSA-Cusp experiment

The ASACUSA-Cusp collaboration has recently upgraded the positron system to improve the production of antihydrogen. Previously, the experiment suffered from contamination of the vacuum in the antihydrogen production trap due to the transfer of positrons from the high pressure region of a buffer gas trap. This contamination reduced the lifetime of antiprotons. By adding a new positron accumulator and therefore decreasing the number of transfer cycles, the contamination of the vacuum has been reduced. Further to this, a new rare gas moderator and buffer gas trap, previously used at the Aarhus University, were installed. Measurements from Aarhus suggested that the number of positrons could be increased by a factor of four in comparison to the old system used at CERN. This would mean a reduction of the time needed for accumulating a sufficient number of positrons (of the order of a few million) for an antihydrogen production cycle. Initial tests have shown that the new system yields a comparable number of positrons to the old system.

physics.atom-ph

Production of antihydrogen atoms by 6 keV antiprotons through a positronium cloud

We report on the first production of an antihydrogen beam by charge exchange of 6.1 keV antiprotons with a cloud of positronium in the GBAR experiment at CERN. The antiproton beam was delivered by the AD/ELENA facility. The positronium target was produced from a positron beam itself obtained from an electron linear accelerator. We observe an excess over background indicating antihydrogen production with a significance of 3-4 standard deviations.

hep-ex

Slow positron production and storage for the ASACUSA-Cusp experiment

The ASACUSA Cusp experiment requires the production of dense positron plasmas with a high repetition rate to produce a beam of antihydrogen. In this work, details of the positron production apparatus used for the first observation of the antihydrogen beam, and subsequent measurements are described in detail. This apparatus replaced the previous compact trap design resulting in an improvement in positron accumulation by a factor of ($52\pm3)$

physics.plasm-ph

SDR, EVC, and SDREVC: Limitations and Extensions

Methods for reducing the radius, temperature, and space charge of nonneutral plasma are usually reported for conditions which approximate an ideal Penning Malmberg trap. Here we show that (1) similar methods are still effective under surprisingly adverse circumstances: we perform SDR and SDREVC in a strong magnetic mirror field using only 3 out of 4 rotating wall petals. In addition, we demonstrate (2) an alternative to SDREVC, using e-kick instead of EVC and (3) an upper limit for how much plasma can be cooled to T < 20 K using EVC. This limit depends on the space charge, not on the number of particles or the plasma density.

physics.plasm-ph

Positron accumulation in the GBAR experiment

We present a description of the GBAR positron (e+) trapping apparatus, which consists of a three stage Buffer Gas Trap (BGT) followed by a High Field Penning Trap (HFT), and discuss its performance. The overall goal of the GBAR experiment is to measure the acceleration of the neutral antihydrogen (H) atom in the terrestrial gravitational field by neutralising a positive antihydrogen ion (H+), which has been cooled to a low temperature, and observing the subsequent H annihilation following free fall. To produce one H+ ion, about 10^10 positrons, efficiently converted into positronium (Ps), together with about 10^7 antiprotons (p), are required. The positrons, produced from an electron linac-based system, are accumulated first in the BGT whereafter they are stacked in the ultra-high vacuum HFT, where we have been able to trap 1.4(2) x 10^9 positrons in 1100 seconds.

physics.plasm-ph

Upgrade of ASACUSA's Antihydrogen Detector

The goal of the ASACUSA (Atomic Spectroscopy And Collisions Using Slow Antiprotons) CUSP experiment at CERN's Antiproton Decelerator is to measure the ground state hyperfine splitting of antihydrogen in order to test whether CPT invariance is broken. The ASACUSA hodoscope is a detector consisting of two layers of 32 plastic scintillator bars individually read out by two serially connected silicon photo multipliers (SiPMs) on each end. Two additional layers for position resolution along the beam axis were scintillator fibres, which will now be replaced by scintillating tiles placed onto the existing bars and also read out by SiPMs. If the antiproton of antihydrogen annihilates in the center of the hodoscope, particles (mostly pions) are produced and travel through the various layers of the detector and produce signals. The hodoscope was successfully used during the last data taking period at CERN. The necessary time resolution to discriminate between particles travelling through the detector from outside and particles produced in the center of the detector was achieved by the use of waveform digitisers and software constant fraction discrimination. The disadvantage of this readout scheme was the slow readout speed, which was improved by two orders of magnitude. This was done by omitting the digitisers and replacing them with TDCs reading out the digital time-over-threshold (ToT) signal using leading edge discrimination.

physics.ins-det

Cyclotron cooling to cryogenic temperature in a Penning-Malmberg trap with a large solid angle acceptance

Magnetized nonneutral plasma composed of electrons or positrons couples to the local microwave environment via cyclotron radiation. The equilibrium plasma temperature depends on the microwave energy density near the cyclotron frequency. Fine copper meshes and cryogenic microwave absorbing material were used to lower the effective temperature of the radiation environment in ASACUSA's Cusp trap, resulting in significantly reduced plasma temperature.

physics.plasm-ph

Minimizing plasma temperature for antimatter mixing experiments

The ASACUSA collaboration produces a beam of antihydrogen atoms by mixing pure positron and antiproton plasmas in a strong magnetic field with a double cusp geometry. The positrons cool via cyclotron radiation inside the cryogenic trap. Low positron temperature is essential for increasing the fraction of antihydrogen atoms which reach the ground state prior to exiting the trap. Many experimental groups observe that such plasmas reach equilibrium at a temperature well above the temperature of the surrounding electrodes. This problem is typically attributed to electronic noise and plasma expansion, which heat the plasma. The present work reports anomalous heating far beyond what can be attributed to those two sources. The heating seems to be a result of the axially open trap geometry, which couples the plasma to the external (300 K) environment via microwave radiation.

physics.plasm-ph

Measurement of the Principal Quantum Number Distribution in a Beam of Antihydrogen Atoms

The ASACUSA (Atomic Spectroscopy And Collisions Using Slow Antiprotons) collaboration plans to measure the ground-state hyperfine splitting of antihydrogen in a beam at the CERN Antiproton Decelerator with initial relative precision of 10-6 or better, to test the fundamental CPT (combination of charge conjugation, parity transformation and time reversal) symmetry between matter and antimatter. This challenging goal requires a polarised antihydrogen beam with a sufficient number of antihydrogen atoms in the ground state. The first measurement of the quantum state distribution of antihydrogen atoms in a low magnetic field environment of a few mT is described. Furthermore, the data-driven machine learning analysis to identify antihydrogen events is discussed.

physics.atom-ph

Positron production using a 9 MeV electron linac for the GBAR experiment

For the GBAR (Gravitational Behaviour of Antihydrogen at Rest) experiment at CERN's Antiproton Decelerator (AD) facility we have constructed a source of slow positrons, which uses a low-energy electron linear accelerator (linac). The driver linac produces electrons of 9 MeV kinetic energy that create positrons from bremsstrahlung-induced pair production. Staying below 10 MeV ensures no persistent radioactive activation in the target zone and that the radiation level outside the biological shield is safe for public access. An annealed tungsten-mesh assembly placed directly behind the target acts as a positron moderator. The system produces $5\times10^7$ slow positrons per second, a performance demonstrating that a low-energy electron linac is a superior choice over positron-emitting radioactive sources for high positron flux.

physics.ins-det

Intense beam of metastable Muonium

Precision spectroscopy of the Muonium Lamb shift and fine structure requires a robust source of 2S Muonium. To date, the beam-foil technique is the only demonstrated method for creating such a beam in vacuum. Previous experiments using this technique were statistics limited, and new measurements would benefit tremendously from the efficient 2S production at a low energy muon ($<20$ keV) facility. Such a source of abundant low energy $\mathrm{μ^+}$ has only become available in recent years, e.g. at the Low-Energy Muon beamline at the Paul Scherrer Institute. Using this source, we report on the successful creation of an intense, directed beam of metastable Muonium. We find that even though the theoretical Muonium fraction is maximal in the low energy range of $2-5$ keV, scattering by the foil and transport characteristics of the beamline favor slightly higher $\mathrm{μ^+}$ energies of $7-10$ keV. We estimate that an event detection rate of a few events per second for a future Lamb shift measurement is feasible, enabling an increase in precision by two orders of magnitude over previous determinations.

hep-ex

Antiproton beams with low energy spread for antihydrogen production

A low energy antiproton transport from the ASACUSA antiproton accumulation trap (MUSASHI trap) to the antihydrogen production trap (double cusp trap) is developed. The longitudinal antiproton energy spread after the transport line is 0.23 +- 0.02 eV, compared with 15 eV with a previous method used in 2012. This reduction is achieved by an adiabatic transport beamline with several pulse-driven coaxial coils. Antihydrogen atoms are synthesized by directly injecting the antiprotons into a positron plasma, resulting in the higher production rate.

physics.ins-det