SearcharxivSearch

arXiv subjects

P. Tůma

Publications and source records attributed to P. Tůma.

2 recordsLinked to original sources

Summary of quality control (QC) of ATLAS18 production ITk strip sensors

To address the demanding operational requirements of the High-Luminosity upgrade of the Large Hadron Collider (HL-LHC), the ATLAS experiment is replacing its current Inner Detector with a new all-silicon Inner Tracker (ITk). The ITk will feature an active area of 165 m2, with its outer tracking layers populated by approximately 18,000 ATLAS18 n+-in-p silicon strip sensors. The silicon sensors, available in eight geometries tailored to two barrel and six endcap types, respectively, are designed to tolerate fluences of up to 1.6 x 10^15 neq/cm2 and ionizing doses of 66 Mrad. A comprehensive, multi-year Quality Control (QC) program is underway across multiple international institutes to evaluate these ITk strip sensors for mechanical and electrical conformity. The QC process includes IV/CV characterization, full strip tests, long-term current stability monitoring, visual inspection, and metrology tests. To manage the high throughput of about 500 sensors per month, the collaboration has implemented standardized test procedures, software packages for data monitoring and integrity checks, unified data formats, and automated analysis tools. The standardization ensures consistent pass/fail evaluation and centralized data handling that enables effective identification of trends and anomalies at all sites during the production. This contribution presents an overview of the ITk strip sensor production and QC framework, along with key findings throughout the whole production, such as charge-up of sensors, stability of the leakage currents, nonrecoverable IV breakdown, and low inter-strip isolation within wafers. It provides insights into sensor yield, quality trends, and reviews specific case studies, such as p-stop doping non-uniformity. Over 91% of the production, totaling over 590 batches, were tested and accepted. Six batches were rejected. These account for 2.8% of the total tested sensors.

physics.ins-det

Low dose gamma irradiation study of ATLAS ITk MD8 diodes

Silicon strip detectors developed for the Inner Tracker (ITk) of the ATLAS experiment will operate in a harsh radiation environment of the HL-LHC accelerator. The ITk is thus designed to endure a total fluence of 1.6E15 1MeV n_eq/cm2 and a total ionizing dose (TID) of 66 Mrad in the strip detector region. A radiation-hard n^+-in-p technology is implemented in the ITk strip sensors. To achieve the required radiation hardness, extensive irradiation studies were conducted during sensor development, primarily performed up to the maximal expected total fluence and TID to ensure a full functionality of the detector at its end-of-life. These studies included irradiations of sensors with various particle types and energies, including the Co60 gamma-rays. Our previous results obtained for gamma-irradiated diodes and strip sensors indicate a linear increase of bulk current with TID, while the surface current saturates at the lowest TID levels checked (66 Mrad), preventing a determination of the exact TID for which the observed saturation occurs. This work presents the results coming from irradiations by Co60 gamma-rays to multiple low TIDs, ranging from 0.5 to 100 krad. The detailed study of total, bulk, and surface currents of diodes explores an unknown dependence of surface current on the TID, annealing, and temperature. Additionally, the effect of the p-stop implant between the bias and the guard ring of measured samples is shown. The observations are relevant for the initial operations of the new ATLAS tracker.

physics.ins-det