SearcharxivSearch

arXiv · 2504.20755

Low dose gamma irradiation study of ATLAS ITk MD8 diodes

Abstract

Silicon strip detectors developed for the Inner Tracker (ITk) of the ATLAS experiment will operate in a harsh radiation environment of the HL-LHC accelerator. The ITk is thus designed to endure a total fluence of 1.6E15 1MeV n_eq/cm2 and a total ionizing dose (TID) of 66 Mrad in the strip detector region. A radiation-hard n^+-in-p technology is implemented in the ITk strip sensors. To achieve the required radiation hardness, extensive irradiation studies were conducted during sensor development, primarily performed up to the maximal expected total fluence and TID to ensure a full functionality of the detector at its end-of-life. These studies included irradiations of sensors with various particle types and energies, including the Co60 gamma-rays. Our previous results obtained for gamma-irradiated diodes and strip sensors indicate a linear increase of bulk current with TID, while the surface current saturates at the lowest TID levels checked (66 Mrad), preventing a determination of the exact TID for which the observed saturation occurs. This work presents the results coming from irradiations by Co60 gamma-rays to multiple low TIDs, ranging from 0.5 to 100 krad. The detailed study of total, bulk, and surface currents of diodes explores an unknown dependence of surface current on the TID, annealing, and temperature. Additionally, the effect of the p-stop implant between the bias and the guard ring of measured samples is shown. The observations are relevant for the initial operations of the new ATLAS tracker.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M. Mikeštíková, V. Fadeyev, P. Federičová, P. Gallus, J. Kozáková, J. Kroll, M. Kůtová, J. Kvasnička, P. Tůma, M. Ullán, Y. Unno. 2025-04-29. Low dose gamma irradiation study of ATLAS ITk MD8 diodes. https://arxiv.org/abs/2504.20755

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det