SearcharxivSearch

arXiv subjects

Rizwan Ahmed

Publications and source records attributed to Rizwan Ahmed.

At least 19 recordsLinked to original sources

Design, waterproofing, and mass production of the 3-inch PMT frontend system of JUNO

Over 25,600 3-inch photomultiplier tubes (PMTs) have been instrumented for the central detector of the Jiangmen Underground Neutrino Observatory. Each PMT is equipped with a high-voltage divider and a frontend cable with waterproof sealing. Groups of sixteen PMTs are connected to the underwater frontend readout electronics via specialized multi-channel waterproof connectors. This paper outlines the design and mass production processes for the high-voltage divider, the cable and connector, as well as the waterproof potting of the PMT bases. The results of the acceptance tests of all the integrated PMTs are also presented.

physics.ins-det

Initial performance results of the JUNO detector

The Jiangmen Underground Neutrino Observatory (JUNO) started physics data taking on 26 August 2025. JUNO consists of a 20-kton liquid scintillator central detector, surrounded by a 35 kton water pool serving as a Cherenkov veto, and almost 1000 m$^2$ of plastic scintillator veto on top. The detector is located in a shallow underground laboratory with an overburden of 1800 m.w.e. This paper presents the performance results of the detector, extensively studied during the commissioning of the water phase, the subsequent liquid scintillator filling phase, and the first physics runs. The liquid scintillator achieved an attenuation length of 20.6 m at 430 nm, while the high coverage PMT system and scintillator together yielded about 1785 photoelectrons per MeV of energy deposit at the detector centre, measured using the 2.223 MeV $γ$ from neutron captures on hydrogen with an Am-C calibration source. The reconstructed energy resolution is 3.4% for two 0.511 MeV $γ$ at the detector centre and 2.9% for the 0.93 MeV quenched Po-214 alpha decays from natural radioactive sources. The energy nonlinearity is calibrated to better than 1%. Intrinsic contaminations of U-238 and Th-232 in the liquid scintillator are below 10$^{-16}$ g/g, assuming secular equilibrium. The water Cherenkov detector achieves a muon detection efficiency better than 99.9% for muons traversing the liquid scintillator volume. During the initial science runs, the data acquisition duty cycle exceeded 97.8%, demonstrating the excellent stability and readiness of JUNO for high-precision neutrino physics.

hep-ex

First measurement of reactor neutrino oscillations at JUNO

Neutrino oscillations, a quantum effect manifesting at macroscopic scales, are governed by lepton flavor mixing angles and neutrino mass-squared differences that are fundamental parameters of particle physics, representing phenomena beyond the Standard Model. Precision measurements of these parameters are essential for testing the completeness of the three-flavor framework, determining the mass ordering of neutrinos, and probing possible new physics. The Jiangmen Underground Neutrino Observatory (JUNO) is a 20 kton liquid-scintillator detector located 52.5 km from multiple reactor cores, designed to resolve the interference pattern of reactor neutrinos with sub-percent precision. Here we report, using the first 59.1 days of data collected since detector completion in August 2025, the first simultaneous high-precision determination of two neutrino oscillation parameters, $\sin^2 θ_{12} = 0.3092\,\pm\,0.0087$ and $Δm^2_{21} = (7.50\,\pm\,0.12)\times10^{-5}\;{\rm eV}^2$ for the normal mass ordering scenario, improving the precision by a factor of 1.6 relative to the combination of all previous measurements. These results advance the basic understanding of neutrinos, validate the detector's design, and confirm JUNO's readiness for its primary goal of resolving the neutrino mass ordering with a larger dataset. The rapid achievement with a short exposure highlights JUNO's potential to push the frontiers of precision neutrino physics and paves the way for its broad scientific program.

hep-ex

Prospects for geoneutrino detection with JUNO

Geoneutrinos, which are antineutrinos emitted during the decay of long-lived radioactive elements inside Earth, serve as a unique tool for studying the composition and heat budget of our planet. The Jiangmen Underground Neutrino Observatory (JUNO) experiment in China, which has recently completed construction, is expected to collect a sample comparable in size to the entire existing world geoneutrino dataset in less than a year. This paper presents an updated estimation of sensitivity to geoneutrinos of JUNO using the best knowledge available to date about the experimental site, the surrounding nuclear reactors, the detector response uncertainties, and the constraints expected from the TAO satellite detector. To facilitate comparison with present and future geological models, our results cover a wide range of predicted signal strengths. Despite the significant background from reactor antineutrinos, the experiment will measure the total geoneutrino flux with a precision comparable to that of existing experiments within its first few years, ultimately achieving a world-leading precision of about 8% over ten years. The large statistics of JUNO will also allow separation of the Uranium-238 and Thorium-232 contributions with unprecedented precision, providing crucial constraints on models of formation and composition of Earth. Observation of the mantle signal above the lithospheric flux will be possible but challenging. For models with the highest predicted mantle concentrations of heat-producing elements, a 3-sigma detection over six years requires knowledge of the lithospheric flux to within 15%. Together with complementary measurements from other locations, the geoneutrino results of JUNO will offer cutting-edge, high-precision insights into the interior of Earth, of fundamental importance to both the geoscience and neutrino physics communities.

hep-ex

Simulation of the Background from $^{13}$C$(α, n)^{16}$O Reaction in the JUNO Scintillator

Large-scale organic liquid scintillator detectors are highly efficient in the detection of MeV-scale electron antineutrinos. These signal events can be detected through inverse beta decay on protons, which produce a positron accompanied by a neutron. A noteworthy background for antineutrinos coming from nuclear power reactors and from the depths of the Earth (geoneutrinos) is generated by ($α, n$) reactions. In organic liquid scintillator detectors, $α$ particles emitted from intrinsic contaminants such as $^{238}$U, $^{232}$Th, and $^{210}$Pb/$^{210}$Po, can be captured on $^{13}$C nuclei, followed by the emission of a MeV-scale neutron. Three distinct interaction mechanisms can produce prompt energy depositions preceding the delayed neutron capture, leading to a pair of events correlated in space and time within the detector. Thus, ($α, n$) reactions represent an indistinguishable background in liquid scintillator-based antineutrino detectors, where their expected rate and energy spectrum are typically evaluated via Monte Carlo simulations. This work presents results from the open-source SaG4n software, used to calculate the expected energy depositions from the neutron and any associated de-excitation products. Also simulated is a detailed detector response to these interactions, using a dedicated Geant4-based simulation software from the JUNO experiment. An expected measurable $^{13}$C$(α, n)^{16}$O event rate and reconstructed prompt energy spectrum with associated uncertainties, are presented in the context of JUNO, however, the methods and results are applicable and relevant to other organic liquid scintillator neutrino detectors.

physics.ins-det

Light Drag in a Cavity Magnomechanics

The term "light dragging" describes how the trajectory of light changes as it travels through a moving medium. This phenomenon facilitates the precise detection of incredibly slow speeds of light, which is widely used in quantum gate operations, state transfer, and quantum memory implementations, etc. To the best of our knowledge, this is the first time we have proposed the existence of a light-dragging effect in a magnomechanical system (MMS). The origin of this crucial element stems from nonlinear dipole and magnetostrictive interactions in MMS. Magnomechanical characteristics such as magnon-photon and magnon-phonon couplings have a strong impact on both refractive and group index profile spectra. We also explore that lateral light drag shows a strong dependence on detuning by altering the amplitude and direction of the translational velocity. This enabled us to alter the light's propagation within the magnomechanical system from superluminal to subluminal and vice versa by adjusting the probe's detuning. The ability to control and manipulate the light drag through the MMS could be helpful in designing novel devices with improved functionality at the microscopic scale.

quant-ph

JUNO Sensitivity to Invisible Decay Modes of Neutrons

We explore the decay of bound neutrons into invisible particles (e.g., $n\rightarrow 3 ν$ or $nn \rightarrow 2 ν$) in the JUNO liquid scintillator detector, which do not produce an observable signal. The invisible decay includes two decay modes: $ n \rightarrow { inv} $ and $ nn \rightarrow { inv} $. The invisible decays of $s$-shell neutrons in $^{12}{\rm C}$ will leave a highly excited residual nucleus. Subsequently, some de-excitation modes of the excited residual nuclei can produce a time- and space-correlated triple coincidence signal in the JUNO detector. Based on a full Monte Carlo simulation informed with the latest available data, we estimate all backgrounds, including inverse beta decay events of the reactor antineutrino $\barν_e$, natural radioactivity, cosmogenic isotopes and neutral current interactions of atmospheric neutrinos. Pulse shape discrimination and multivariate analysis techniques are employed to further suppress backgrounds. With two years of exposure, JUNO is expected to give an order of magnitude improvement compared to the current best limits. After 10 years of data taking, the JUNO expected sensitivities at a 90% confidence level are $τ/B( n \rightarrow { inv} ) > 5.0 \times 10^{31} \, {\rm yr}$ and $τ/B( nn \rightarrow { inv} ) > 1.4 \times 10^{32} \, {\rm yr}$.

hep-ex

Potential to identify neutrino mass ordering with reactor antineutrinos at JUNO

The Jiangmen Underground Neutrino Observatory (JUNO) is a multi-purpose neutrino experiment under construction in South China. This paper presents an updated estimate of JUNO's sensitivity to neutrino mass ordering using the reactor antineutrinos emitted from eight nuclear reactor cores in the Taishan and Yangjiang nuclear power plants. This measurement is planned by studying the fine interference pattern caused by quasi-vacuum oscillations in the oscillated antineutrino spectrum at a baseline of 52.5~km and is completely independent of the CP violating phase and neutrino mixing angle $θ_{23}$. The sensitivity is obtained through a joint analysis of JUNO and Taishan Antineutrino Observatory (TAO) detectors utilizing the best available knowledge to date about the location and overburden of the JUNO experimental site, local and global nuclear reactors, JUNO and TAO detector responses, expected event rates and spectra of signals and backgrounds, and systematic uncertainties of analysis inputs. We find that a 3$σ$ median sensitivity to reject the wrong mass ordering hypothesis can be reached with an exposure to approximately 6.5 years $\times$ 26.6 GW thermal power.

hep-ex

Perfect Transfer of Entanglement and One-Way Quantum Steering via Parametric Frequency Converter in a Two-mode Cavity Magnomechanical System

We study the effects of a parametric frequency converter in a two-mode cavity system where one of the cavity mode is coupled with yttrium iron garnet (YIG) via magnetic dipole interaction. Parametric frequency converter acts as a nonlinear source for enhanced entanglement among all bipartitions and asymmetrical quantum steering. The behavior of the two types of quantum correlations are shown to be dependent on parametric coupling and the associated phase factor. We show that cavity-cavity entanglement and cavity-phonon entanglement (cavity-magnon entanglement) decreases (increases) with the increase of the parametric phase factor ϕ. In addition, generated entanglements in the present system have shown to be more robust against the thermal effects, with the inclusion of the parametric converter as compared with the bare cavity case. Another intriguing finding is the asymmetric one-way steering, where we notice that magnon and phonon modes can steer the indirectly coupled cavity modes, yet the steering in swapped direction is not observed. It is of great interest that the perfect transfer of entanglement and quantum steering is achieved among different modes by adjusting the system's parameters. In fact, our protocol for these transferring processes suggests a different approach to the processing and storage of quantum information.

quant-ph

Phase-Sensitive Enhanced Absorption, Transmission and Slow Light in a Cross-cavity Magnomechanical System

We theoretically propose a scheme to explore the magnetically and magnomechanically induced transparency phenomena in a cross-cavity magnomechanical system, focusing on the role of relative phase and the intensity of the two probing fields in enhancing the absorption and transmission spectra and manipulating the group delay of the transmitted light. Interestingly, the relative phase of the two probe fields could have overwhelming effects on both the absorption spectrum and the group delay of the output field. Tuning the relative phase and amplitude of the probe fields can suppress or enhance the absorption and transmission spectra. The combined effect of the magnon-photon and magnon-phonon couplings, along with relative phase modulations, helps to switch the probe field's behavior from subluminal to superluminal in the current system. The current study offers a straightforward and practical approach, demonstrating the capability to employ the relative phase for the modulation of microwave signals within the cavity magnomechanical system, providing insights for the design of information transduction and quantum sensing.

quant-ph

Prediction of Energy Resolution in the JUNO Experiment

This paper presents an energy resolution study of the JUNO experiment, incorporating the latest knowledge acquired during the detector construction phase. The determination of neutrino mass ordering in JUNO requires an exceptional energy resolution better than 3\% at 1~MeV. To achieve this ambitious goal, significant efforts have been undertaken in the design and production of the key components of the JUNO detector. Various factors affecting the detection of inverse beta decay signals have an impact on the energy resolution, extending beyond the statistical fluctuations of the detected number of photons, such as the properties of the liquid scintillator, performance of photomultiplier tubes, and the energy reconstruction algorithm. To account for these effects, a full JUNO simulation and reconstruction approach is employed. This enables the modeling of all relevant effects and the evaluation of associated inputs to accurately estimate the energy resolution. The results of study reveal an energy resolution of 2.95\% at 1~MeV. Furthermore, this study assesses the contribution of major effects to the overall energy resolution budget. This analysis serves as a reference for interpreting future measurements of energy resolution during JUNO data collection. Moreover, it provides a guideline for comprehending the energy resolution characteristics of liquid scintillator-based detectors.

hep-ex

Nonreciprocal Multipartite Entanglement in a two-cavity magnomechanical system

We propose a theoretical scheme for the generation of nonreciprocal multipartite entanglement in a two-mode cavity magnomechanical system, consisting of two cross-microwave (MW) cavities having a yttrium iron garnet (YIG) sphere, which is coupled through magnetic dipole interaction. Our results show that the self-Kerr effect of magnon can significantly enhance multipartite entanglement, which turns out to be nonreciprocal when the magnetic field is tuned along the crystallographic axis [110]. This is due to the frequency shift on the magnons (YIG sphere), which depends on the direction of the magnetic field. Interestingly, the degree of nonreciprocity of bipartite entanglements depends upon a careful optimal choice of system parameters like normalized cavity detunings, bipartite nonlinear index, self-Kerr coefficient, and effective magnomechanical coupling rate G. In addition to bipartite entanglement, we also present the idea of a bidirectional contrast ratio, which quantifies the nonreciprocity in tripartite entanglements. Our present theoretical proposal for nonreciprocity in multipartite entanglement may find applications in diverse engineering nonreciprocal devices

quant-ph

Nanomechanically induced transparency in $\mathcal{PT}$-symmetric optical cavities

In this paper, we analytically present the phenomena of nanomechanically induced transparency (NMIT) and transmission rate in a parity-time-symmetric ($\mathcal{PT}$-symmetric) opto-nanomechanical system (ONMS) where a levitated dielectric nanospheres is trapped near the antinodes closest to right mirror of passive cavity which further coupled to an active cavity via hoping factor. We find that the phenomenon of NMIT may be generated from the output probe field in the presence of an effective opto-nanomechanical coupling between the cavity field and the nanosphere, whose steady-state position is influenced by the Coulomb interaction between the cavity mirror and the nanosphere. In addition, the width and height of the transparency window can be controlled through the effective optomechanical coupling, which is readily adjusted by altering changing the nanosphere's radius and the Coulomb interaction. One of the most interesting result is the transition NMIT behavior in $\mathcal{PT}$-symmetric and broken $\mathcal{PT}$-symmetric regime. We show that the presence of nanosphere in the passive cavity enhances the width and transmission rate of NMIT window in passive-passive regime and in passive-active regime, a notable decrease of sideband amplification has been observed. These results show that our scheme may find some potential applications for optical signal processing an and quantum information processing.

quant-ph

Model Independent Approach of the JUNO $^8$B Solar Neutrino Program

The physics potential of detecting $^8$B solar neutrinos will be exploited at the Jiangmen Underground Neutrino Observatory (JUNO), in a model independent manner by using three distinct channels of the charged-current (CC), neutral-current (NC) and elastic scattering (ES) interactions. Due to the largest-ever mass of $^{13}$C nuclei in the liquid-scintillator detectors and the {expected} low background level, $^8$B solar neutrinos would be observable in the CC and NC interactions on $^{13}$C for the first time. By virtue of optimized event selections and muon veto strategies, backgrounds from the accidental coincidence, muon-induced isotopes, and external backgrounds can be greatly suppressed. Excellent signal-to-background ratios can be achieved in the CC, NC and ES channels to guarantee the $^8$B solar neutrino observation. From the sensitivity studies performed in this work, we show that JUNO, with ten years of data, can reach the {1$σ$} precision levels of 5%, 8% and 20% for the $^8$B neutrino flux, $\sin^2θ_{12}$, and $Δm^2_{21}$, respectively. It would be unique and helpful to probe the details of both solar physics and neutrino physics. In addition, when combined with SNO, the world-best precision of 3% is expected for the $^8$B neutrino flux measurement.

hep-ex

Enhancement of Entanglement via Josephson Parametric Amplifier in a Dual Cavity-Magnon System

In the two microwave (MW) cross-shaped cavity magnon system, we describe a method to produce multipartite entanglement and quantum steering. To achieve squeezed states of the magnons, a Josephson parametric amplifier (JPA) creates a squeezed vacuum field that drives the two cavities. We theoretically demonstrate that the cavity-cavity entanglement can be generated at the resonance point, however, increasing the cavity and magnon decay rates generate the cavity-magnon entanglement. By changing the squeezing parameter and increasing the decay rates, we can transfer the cavity-cavity entanglement to cavity-magnon entanglement. Furthermore, the cavity-cavity entanglement (survive up to 2.8K) not only found to be much stronger but also more robust as compared to cavity-magnon entanglement (survive up to 0.4K). More importantly, the genuine photon-magnon-photon tripartite entanglement could be achieved, which is robust against the thermal fluctuations and depends strongly on squeezing parameter. Furthermore, for current dual cavity-magnon system, two-way quantum steering is found when the optomagnonical couplings are equal. The current study offers a straightforward and practical method for achieving multipartite quantum correlations.

quant-ph

Real-time Monitoring for the Next Core-Collapse Supernova in JUNO

The core-collapse supernova (CCSN) is considered one of the most energetic astrophysical events in the universe. The early and prompt detection of neutrinos before (pre-SN) and during the supernova (SN) burst presents a unique opportunity for multi-messenger observations of CCSN events. In this study, we describe the monitoring concept and present the sensitivity of the system to pre-SN and SN neutrinos at the Jiangmen Underground Neutrino Observatory (JUNO), a 20 kton liquid scintillator detector currently under construction in South China. The real-time monitoring system is designed to ensure both prompt alert speed and comprehensive coverage of progenitor stars. It incorporates prompt monitors on the electronic board as well as online monitors at the data acquisition stage. Assuming a false alert rate of 1 per year, this monitoring system exhibits sensitivity to pre-SN neutrinos up to a distance of approximately 1.6 (0.9) kiloparsecs and SN neutrinos up to about 370 (360) kiloparsecs for a progenitor mass of 30 solar masses, considering both normal and inverted mass ordering scenarios. The pointing ability of the CCSN is evaluated by analyzing the accumulated event anisotropy of inverse beta decay interactions from pre-SN or SN neutrinos. This, along with the early alert, can play a crucial role in facilitating follow-up multi-messenger observations of the next galactic or nearby extragalactic CCSN.

hep-ex

JUNO Sensitivity on Proton Decay $p\to \barνK^+$ Searches

The Jiangmen Underground Neutrino Observatory (JUNO) is a large liquid scintillator detector designed to explore many topics in fundamental physics. In this paper, the potential on searching for proton decay in $p\to \barνK^+$ mode with JUNO is investigated.The kaon and its decay particles feature a clear three-fold coincidence signature that results in a high efficiency for identification. Moreover, the excellent energy resolution of JUNO permits to suppress the sizable background caused by other delayed signals. Based on these advantages, the detection efficiency for the proton decay via $p\to \barνK^+$ is 36.9% with a background level of 0.2 events after 10 years of data taking. The estimated sensitivity based on 200 kton-years exposure is $9.6 \times 10^{33}$ years, competitive with the current best limits on the proton lifetime in this channel.

hep-ex

JUNO sensitivity to the annihilation of MeV dark matter in the galactic halo

We discuss JUNO sensitivity to the annihilation of MeV dark matter in the galactic halo via detecting inverse beta decay reactions of electron anti-neutrinos resulting from the annihilation. We study possible backgrounds to the signature, including the reactor neutrinos, diffuse supernova neutrino background, charged- and neutral-current interactions of atmospheric neutrinos, backgrounds from muon-induced fast neutrons and cosmogenic isotopes. A fiducial volume cut, as well as the pulse shape discrimination and the muon veto are applied to suppress the above backgrounds. It is shown that JUNO sensitivity to the thermally averaged dark matter annihilation rate in 10 years of exposure would be significantly better than the present-day best limit set by Super-Kamiokande and would be comparable to that expected by Hyper-Kamiokande.

hep-ex