SearcharxivSearch

arXiv subjects

Sergey Vasilyev

Publications and source records attributed to Sergey Vasilyev.

12 recordsLinked to original sources

Record nonlinear conversion efficiency in the production of high spectral purity vacuum ultraviolet laser at 148 nm

Coherent vacuum-ultraviolet (VUV) lasers are indispensable for precision measurement, quantum optics, and materials science. Recent high-resolution spectroscopy of the Th-229 nuclear clock transition near 148 nm highlights the urgent demand for intense, narrow-linewidth VUV lasers for advancing metrology and testing fundamental physics. However, existing VUV generation schemes typically require enhancement cavities [C. Zhang et al., Opt. Lett. 47, 5591-5594 (2022)], atomic resonances [Q. Xiao et al., Nature 650, 852-856 (2026)], or random quasi-phase-matched nonlinear crystals [V. Lal et al., Optica 12, 1971-1974 (2025)]. Here, we demonstrate a VUV frequency comb via cascaded frequency doubling of a 2400 nm Cr:ZnS comb to its 16th harmonic in nonlinear crystals. The final stage employs a bulk-grown, spatially uniform quasi-phase matched (QPM) crystal developed by IPG, combining VUV transparency, high $\chi^2$ nonlinearity, and power scalability. Using this QPM crystal we generate a VUV frequency comb with 40 $\mu$W average power (1 nW per mode at 80 MHz mode spacing) with a conversion efficiency order of magnitude higher than other known methods. These results establish a scalable route to compact VUV sources via direct frequency doubling, opening a path toward a robust continuous-wave nuclear clock laser.

physics.optics

Characterization of Aluminum Microwave SQUID Multiplexers for CE$\nu$NS Detection

We present the design, fabrication, and characterization of an aluminum-based six-channel microwave SQUID multiplexer ($\mu$MUX) prototype for transition-edge sensor (TES) readout in the RICOCHET experiment. The device consists of aluminum coplanar-waveguide resonators and RF SQUIDs with Dolan-style Al/AlO$_x$/Al Josephson junctions. By measuring the resonator scattering parameters at a range of probe tone frequencies, powers, and flux bias points, we demonstrate agreement between the device response and existing multiplexer models. We also characterize the noise performance in both open-loop and flux-ramping modes. With a high electron mobility transistor (HEMT) amplifier, open-loop measurements yield a flux sensitivity of 1-1.5 $\mu\Phi_0/\sqrt{Hz}$. With flux-ramp modulation, low-frequency 1/f noise is suppressed, and the flux sensitivity is around 3-4 $\mu\Phi_0/\sqrt{Hz}$, corresponding to a current sensitivity of 24-33 $pA/\sqrt{Hz}$ at the input coil. We further demonstrate a reduction in readout noise by incorporating a Josephson traveling-wave parametric amplifier (JTWPA) between the $\mu$MUX and the HEMT. This achieves an open-loop flux sensitivity of 0.3-0.6 $\mu\Phi_0/\sqrt{Hz}$ and an effective system noise temperature below 1 K. These results establish aluminum $\mu$MUX devices as a viable and extensible readout technology for low-noise cryogenic detector arrays.

physics.ins-det

Long-wave infrared Fourier transform spectroscopy with enhanced and scalable sensitivity

We report a broadband long-wave infrared Fourier transform spectrometer with sensitivity exceeding that of previously reported direct-detection implementations. The system combines dual-comb spectroscopy with electro-optic sampling, multi-channel parallel near-infrared detection using InGaAs photodiodes, and real-time GPU-based computational corrections of multiple spectroscopy signals. Detection limits of 0.3 ppb for NH$_{3}$ and 2 ppb for C$_{2}$H$_{4}$ are achieved in 500 s, corresponding to 20x and 40x sensitivity improvements over earlier LWIR demonstrations, while maintaining high 0.0027 cm$^{-1}$ spectral resolution and broad spectral coverage. The architecture supports scalable sensitivity through increased detector count and enables rapid multispecies analysis of complex gas mixtures.

physics.optics

Characterization of mini-CryoCube detectors from the Ricochet experiment commissioning at the Institut Laue-Langevin

The Ricochet experiment aims to measure the coherent elastic neutrino-nucleus scattering process from antineutrinos emitted by a research nuclear reactor operated by the Institut Laue-Langevin (Grenoble, France). This article presents a description of the Ricochet experimental installation and the detector performance achieved during its commissioning with a mini-CryoCube module consisting of three 42-gram germanium cryogenic calorimeters. The baseline resolutions and background levels are reported both during reactor-on and reactor-off periods, and as noise mitigation techniques were improved. A baseline resolution of 40 eV electron equivalent was achieved for the ionization channel after setup improvements, and the phonon channel resolutions ranged from 50 to 80 eV of total phonon energy. In the energy region from 2 to 7 keV, a nuclear recoil rate of 15(2) events/(kg day keV) is measured during the reactor-off period selecting events in coincidence with muon veto signals. This rate is in agreement with the cosmogenic neutron rate calculated from GEANT4 simulations. After the rejection of events in coincidence with signals in the muon veto detectors, a combined 90% C.L. limit on the nuclear recoil background of < 9 events/(kg day keV) is obtained in that energy region during the reactor-on period, which is compatible with our GEANT4 model calculation corresponding to a total rate of 5 events/(kg day keV). The sensitivity of this analysis was however found to be limited by a surface event contamination which is currently being addressed by the Ricochet Collaboration with upgraded detectors.

hep-ex

Phase Noise Characterization of Cr:ZnS Frequency Comb using Subspace Tracking

We present a comprehensive phase noise characterization of a mid-IR Cr:ZnS frequency comb. Despite their emergence as a platform for high-resolution dual-comb spectroscopy, detailed investigations into the phase noise of Cr:ZnS combs have been lacking. To address this, we use a recently proposed phase noise measurement technique that employs multi-heterodyne detection and subspace tracking. This allows for the measurement of the common mode, repetition-rate and high-order phase noise terms, and their corresponding scaling as a function of a comb-line number, using a single measurement set-up. We demonstrate that the comb under test is dominated by the common mode phase noise, while all the other phase noise terms are below the measurement noise floor (~ -120 dB rad^2/Hz), and are thereby not identifiable.

physics.optics

High-resolution electro-optically sampled broadband dual-comb spectroscopy across mid-IR to terahertz at video rate

Ultrabroadband electro-optic sampling with few-cycle optical pulses is known to be an extremely sensitive technique to detect electric field amplitudes. By combining this method with dual-comb spectroscopy and with a new class of ultrafast lasers, we perform high-resolution (<10 MHz, 0.0003 wavenumbers) spectroscopic measurements across the whole frequency range of 1.5 to 45 THz (6.6-200 microns) with an instantaneous spectral coverage exceeding an octave (e.g., 9-22 microns). As a driving source, we use a pair of highly mutually-coherent low-noise frequency combs centered at 2.35 microns produced by mode-locked solid-state Cr: ZnS lasers. One of the two combs is frequency downconverted via intrapulse difference frequency generation to produce a molecular sensing comb, while the second comb is frequency doubled to produce a near-IR comb for electro-optic sampling (EOS). An ultra-low intensity and phase noise of our dual-comb system allows capturing a vast amount of longwave spectral information (>200,000 comb-mode spectral lines) at up to a video rate of 69 Hz and with the high dynamic range limited by the shot noise of the near-IR EOS balanced detection. Our long-wavelength IR measurements with low-pressure gases: ethanol, isoprene, and dimethyl sulfide reveal spectroscopic features that had never been explored before.

physics.optics

Video-rate broadband longwave IR dual-comb spectroscopy with 240,000 comb-mode resolved data points

We report molecular detection using dual frequency-comb spectroscopy with highly coherent broadband (6.6-11.4 {\m}m) long-wavelength infrared (LWIR) combs. The combs were produced via intra-pulse difference frequency generation (IDFG) in ZGP crystals using sub-three-cycle (20 fs) driving pulses from mode-locked Cr:ZnS lasers at the central wavelength of 2.4 {\m}m). Real-time and up to video rate (0.1-12 s per spectrum) acquisition of molecular spectra with some 240,000 comb-mode-resolved data points spaced by 80 MHz and referenced to a Rb clock with a signal-to-noise ratio (SNR) >300 has been demonstrated. The key to achieving such a high rate of massive spectral data acquisition is a low phase and intensity noise of the LWIR combs and excellent mutual coherence. The high SNR was also facilitated by the high (7.5%) IDFG conversion efficiency resulting in an average LWIR comb power of 300 mW per channel.

physics.optics

Status Update of the MAJORANA DEMONSTRATOR Neutrinoless Double Beta Decay Experiment

Neutrinoless double beta decay searches play a major role in determining neutrino properties, in particular the Majorana or Dirac nature of the neutrino and the absolute scale of the neutrino mass. The consequences of these searches go beyond neutrino physics, with implications for Grand Unification and leptogenesis. The \textsc{Majorana} Collaboration is assembling a low-background array of high purity Germanium (HPGe) detectors to search for neutrinoless double-beta decay in $^{76}$Ge. The \textsc{Majorana Demonstrator}, which is currently being constructed and commissioned at the Sanford Underground Research Facility in Lead, South Dakota, will contain 44 kg (30 kg enriched in $^{76}$Ge) of HPGe detectors. Its primary goal is to demonstrate the scalability and background required for a tonne-scale Ge experiment. This is accomplished via a modular design and projected background of less than 3 cnts/tonne-yr in the region of interest. The experiment is currently taking data with the first of its enriched detectors.

physics.ins-det

Robust frequency stabilization of multiple spectroscopy lasers with large and tunable offset frequencies

We demonstrate a compact and robust device for simultaneous absolute frequency stabilization of three diode lasers whose carrier frequencies can be chosen freely relative to the reference. A rigid ULE multi-cavity block is employed, and, for each laser, the sideband locking technique is applied. Useful features of the system are a negligible lock error, computer control of frequency offset, wide range of frequency offset, simple construction, and robust operation. One concrete application is as a stabilization unit for the cooling and trapping lasers of a neutral atom lattice clock. The device significantly supports and improves the operation of the clock. The laser with the most stringent requirements imposed by this application is stabilized to a linewidth of 70 Hz, and a residual frequency drift less than 0.5 Hz/s. The carrier optical frequency can be tuned over 350 MHz while in lock.

physics.optics

Spectrally narrow, long-term stable optical frequency reference based on a Eu$^{3+}$:Y$_{2}$SiO$_{5}$ crystal at cryogenic temperature

Using an ultrastable continuous-wave laser at 580 nm we performed spectral hole burning of Eu$^{3+}$:Y$_{2}$SiO$_{5}$ at very high spectral resolution. Essential parameters determining the usefulness as a "macroscopic" frequency reference: linewidth, temperature sensitivity, long-term stability were characterized, using a H-maser stabilized frequency comb. Spectral holes with linewidth as low as 6 kHz were observed and the upper limit of the drift of the hole frequency was determined to be on the order of 5$\pm$3 mHz/s. We discuss necessary requirements for achieving ultra-high-stability in laser frequency stabilization to these spectral holes.

physics.optics

Genus two Veech surfaces arising from general quadratic differentials

We study Veech surfaces of genus 2 arising from quadratic differentials that are not squares of abelian differentials. We prove that all such surfaces of type (2,2) and (2,1,1) are arithmetic. In (1,1,1,1) case, we reduce the question to abelian differentials of type (2,2) on hyperelliptic genus 3 surfaces with singularities at Weierstrass points, and we give an example of a non-arithmetic Veech surface.

math.GT