Spectacular - A Modular DAQ System for Microdosimetry

Particle therapy using light ions like protons, helium ions or carbon ions enables precise tumor targeting with enhanced biological effectiveness while minimizing damage to healthy tissue. Successful treatment planning depends not only on the absorbed dose but also on quality of the radiation, as quantified by the linear energy transfer (LET). Microdosimetry provides a direct experimental determination of such quantities by measuring the energy deposited per incoming particle in micrometer-sized solid-state detectors representing the relevant biological scales. However, the small signal amplitudes and high particle rates in therapeutic ion beams challenge existing readout systems, which are not sufficiently optimized for reliable operation with respect to pileup and signal-to-noise ratio (SNR). To address this, a modular data acquisition (DAQ) system was developed to accelerate the design of custom readout electronics and sensor characterization in microdosimetry and related spectroscopic applications. Centered around a Xilinx Zynq system-on-chip, it combines real-time processing, high-bandwidth streaming, and high-resolution digitization (16 bit at 100 MSas$^{-1}$) to enable advanced digital signal processing. The platform integrates programmable power supplies, a bias-voltage filter, test-pulse generators, and flexible I/O. Detector and preamplifier front-ends are hosted on interchangeable daugtherboards connected via a standardized interface, allowing different hardware configurations and readout algorithms to be evaluated on the same platform. The Spectacular DAQ system was successfully tested at the MedAustron ion therapy facility with custom charge-sensitive amplifiers and a diamond microdosimeter. First results demonstrate the feasibility and provide a proof-of-concept for potential future applications in clinical practice.

physics.ins-det

The RD50-MPW4: A Radiation Hard HV CMOS Sensor for Future Colliders

The former CERN RD50 collaboration develops monolithic active pixel high voltage (HV) CMOS sensors for future colliders with the aim of high radiation tolerance, good time resolution, and high granularity pixel detectors. The most recent prototype, the RD50-MPW4, was produced by LFoundry in December 2023 using a 150 nm CMOS process. It features a matrix of 64x64 pixels with a 62 $\mu$m pitch and employs a column-drain readout architecture. Compared to its predecessor, it now has separate analog and digital power domains and a new biasing scheme with a guard ring structure that supports bias voltages over 600 V. This contribution will discuss the design and latest results of the MPW4, where tests with unirradiated samples showed more than 99.9% efficiency, 16 $\mu$m spatial resolution and 10 ns timing resolution. Efficiencies of over 99% were achieved for samples irradiated to fluences of $1 \times 10^{15}$ 1 MeV n$_{\mathrm{eq}}/\mathrm{cm}^2$. A 3D map of the charge collection efficiency from a measurement with two-photon absorption laser is presented that nicely outlines the depletion depth of this radiation hard, high granularity monolithic active pixel sensor.

physics.ins-det

Characterization of p-stop isolation implants in silicon sensors using MOSFET structures

Metal-oxide-semiconductor field-effect transistor (MOSFET) test structures are investigated to characterize p-stop isolation implants between n-type electrodes in p-type silicon sensors. The device transfer characteristics are measured as a function of the voltage applied to the backside to extract the threshold voltage, which quantifies inter-electrode isolation, and the field-dependent mobility parameters. We present a methodology to reconstruct depth-dependent doping profiles from the threshold voltage characteristics, accounting for the localized space-charge effects and electric-field screening induced by the p-stop implants. The study evaluates the sensitivity of this technique to various p-stop geometries and doping concentrations across different wafer types. The results demonstrate the potential of MOSFET-based structures as a non-destructive diagnostic for monitoring p-stop consistency and inter-electrode isolation properties in silicon detectors.

physics.ins-det

Measurements and simulations of X-ray radiation damage effects on CNM n-type 4H-SiC MOS capacitors

Silicon carbide is a promising material for radiation-hard detectors due to its wide bandgap, low leakage current, high critical electric field, and high saturation velocity. A key obstacle for its use in high-radiation environments is the incomplete understanding of surface damage at the 4H-SiC/SiO$_2$ interface.In this work, we present a combined experimental and TCAD simulation study of X-ray radiation-induced surface damage on n-type 4H-SiC MOS capacitors fabricated at CNM (Centro Nacional de Microelectronica, Barcelona), irradiated up to 10 Mrad. High-frequency (100 kHz) and quasi-static capacitance-voltage (C--V) measurements are used to evaluate the evolution of fixed oxide charge density and interface trap density as a function of dose.A dose-dependent TCAD surface model is developed and validated against the full set of measurements. The optimized model reproduces the measured C--V characteristics across the entire irradiation range and provides a physically grounded baseline for simulations of n-type 4H-SiC-based detectors. It can be used as a starting point for predictive modeling of irradiated detectors.

physics.ins-det

A frontend ASIC for Microdosimetry

Recent clinical evidence shows a correlation between linear energy transfer (LET) and tumor control in carbon ion radiotherapy. This prompts the direct inclusion of LET into the treatment planning. Currently, LET is mainly extracted from simulations. Good clinical practice requires adopting measurement routines that correlate with LET, such as microdosimetry. In this work, we describe an application-specific integrated circuit (ASIC) for reading out microdosimeteric sensors. The ASIC is designed for input capacitances up to 3 pF. It contains four readout channels, each with a different saturation charge ranging from 75 fC to 3.2 pC. In the 75 fC range, at 1 pF input capacitance and a shaping time of 1 microseconds, the ASIC has an equivalent noise contribution (ENC) below 15 electrons at ambient temperature. This low noise level is expected to enable new measurement possibilities, including the assessment of microdosimetric proton spectra in the low-LET region of the entrance channel, as well as studying the contribution of delta electrons.

hep-ex

Measurements of the micro-spill structure of medical cyclotron and synchrotron beams and its impact on pulse pileup

Detector characterization and instrumentation testing are often performed at cyclotron and synchrotron facilities, many of which were originally developed for medical applications in cancer therapy. For particle physics experiments requiring a single-particle resolution, pileup can significantly degrade data quality, making precise knowledge of the beam time structure essential for selecting appropriate readout parameters. However, such information is often unavailable from the facilities and challenging to determine experimentally. Here, we report measurements of the spill time structure at two medical accelerator facilities using a silicon carbide (SiC) particle sensor coupled to a high-frequency readout system. Owing to its high carrier saturation velocity and the tolerance to large bias voltages, SiC is well suited for fast readout and measurements requiring precise timing. Using a 6 GHz readout with custom SiC diodes, we characterize the micro-spill structure of both cyclotron and synchrotron beams on a sub-nanosecond timescale. The measured arrival-time distributions exhibit modulation with the accelerator RF frequencies, reflecting features of the extraction process. The resolved micro-spill structure enables quantitative estimation of pileup contributions and provides design constraints for future readout electronics. The presented results emphasize the importance of the characterization of the beam time-structure characterization for the development of precise readout systems.

physics.ins-det

Physics Briefing Book: Input for the 2026 update of the European Strategy for Particle Physics

The European Strategy for Particle Physics (ESPP) reflects the vision and presents concrete plans of the European particle physics community for advancing human knowledge in fundamental physics. The ESPP is updated every five-to-six years through a community-driven process. It commences with the submission of specific proposals and other input from the community at large, outlining projects envisioned for the near-, mid-, and long-term future. All submitted contributions are evaluated by the Physics Preparatory Group (PPG), and a preliminary analysis is presented at a Symposium meant to foster a broad community discussion on the scientific value and feasibility of the various ideas proposed. The outcomes of the analysis and the deliberations at the Symposium are synthesized in the current Briefing Book, which provides an important input in the deliberations of the Strategy recommendations by the European Strategy Group (ESG).

hep-ex

Design and simulation of a 4H-SiC low gain avalanche diode with trench-isolation

We present the design and simulation of a 30 $\mathrm{\mu m}$ thick 4H-SiC Low Gain Avalanche Diode (LGAD) optimized for high-voltage operation. A 2.4 $\mathrm{\mu m}$ thick epitaxially grown gain layer enables controlled internal amplification up to 1 kV reverse bias, while maintaining full depletion below 500 V. Electrical characteristics, including I-V, C-V, and gain behavior, were simulated in Synopsys Sentaurus Technology Computer-Aided Design (TCAD) using a quasi-1D geometry and verified across process-related variations in gain layer parameters. To ensure high-voltage stability and proper edge termination, a guard structure combining deep etched trenches and deep $p^+$ junction termination extension (JTE) implants was designed. TCAD simulations varying the guard structure dimensions yielded an optimized design with a breakdown voltage above 2.4 kV. A corresponding wafer run is currently processed at IMB-CNM, Barcelona.

physics.ins-det

In-situ Radiation Damage Study of Silicon Carbide Detectors Subjected to Clinical Proton Beams

Silicon carbide (SiC) planar PiN diodes from two different manufacturers were irradiated with 252.7 MeV protons from a medical synchrotron. Over the course of two 8h irradiation shifts, the samples were exposed to increasing fluences ranging from 1.4e+11 to 3.5e+13 p+/cm^2. Electrical characterizations, including IV and CV measurements, were performed both before and after irradiation using probe stations, and for selected samples even in-situ between fluence steps directly at the irradiation facility. The results show a gradual compensation of the effective epitaxial doping concentration with each incremental fluence step, observed as a reduction in capacitance before full depletion and confirmed by the extracted effective doping concentration. From these measurements, linear donor removal rates are determined for all sample groups, with values ranging from 4.2/cm to 6.4/cm. These findings provide a quantitative basis for understanding radiation-induced charge carrier removal in 4H-SiC devices and are relevant for predicting the performance and lifetime of future radiation-hard detector technologies, including 4H-SiC LGADs.

physics.ins-det

Extraction of Electron and Hole Drift Velocities in thin 4H-SiC PIN Detectors using High-Frequency Readout Electronics

Silicon carbide (SiC) has been widely adopted in the semiconductor industry, particularly in power electronics, because of its high temperature stability, high breakdown field, and fast switching speeds. Its wide band gap makes it an interesting candidate for radiation-hard particle detectors in high-energy physics and medical applications. Furthermore, the high electron and hole drift velocities in 4H-SiC enable devices suitable for ultra-fast particle detection and timing applications. However, currently, the front-end readout electronics used for 4H-SiC detectors constitute a bottleneck in investigations of the charge carrier drift. To address these limitations, a high-frequency readout board with an intrinsic bandwidth of 10 GHz was developed. With this readout, the transient current signals of a 4H-SiC diode with a diameter of 141 $\mathrm{\mu m}$ and a thickness of 50 $\mathrm{\mu m}$ upon UV-laser, alpha particle, and high-energy proton beam excitation were recorded. In all three cases, the electron and hole drift can clearly be separated, which enables the extraction of the charge carrier drift velocities as a function of the electric field. These velocities, for the first time directly measured, provide a valuable comparison to Monte-Carlo simulated literature values and constitute an essential input for TCAD simulations. Finally, a complete simulation environment combining TCAD, the Allpix$^2$ framework, and SPICE simulations is presented, in good agreement with the measured data.

physics.ins-det

Characterizing the Delivered Spill Structure of Medical Proton and Carbon-Ion Beams at MedAustron using a High Frequency Silicon Carbide Readout

Medical synchrotrons are often used for testing instrumentation in high-energy physics or non-clinical research in medical physics. In many applications of medical synchrotrons, such as microdosimetry and ion imaging, precise knowledge of the spill structure and instantaneous particle rate is crucial. Conventional ionization chambers, while omnipresent in clinical settings, suffer from limitations in charge resolution and integration time, making single-particle detection at high dose rates unfeasible. To address these limitations, we present a beam detection setup based on a silicon carbide (SiC) sensor and a monolithic microwave integrated circuit (MMIC), capable of detecting single particles with a full width at half maximum (FWHM) pulse duration of 500 ps. At the MedAustron ion therapy center, we characterized the spill structure of proton and carbon-ion beams delivered to the irradiation room beyond the timescale of the maximum ion revolution frequency in the synchrotron. The resulting data offer valuable insights into the beam intensity at small time scales and demonstrate the capabilities of SiC-based systems for high-flux beam monitoring.

physics.ins-det

From Single Particles to Clinical Beam Rates: A Wide Dynamic Range Beam Monitor

Access to high-energy particle beams is key for testing high-energy physics (HEP) instruments. Accelerators for cancer treatment can serve as such a testing ground. However, HEP instrument tests typically require particle fluxes significantly lower than for cancer treatment. Thus, facilities need adaptations to fulfill both the requirements for cancer treatment and the requirements for HEP instrument testing. We report on the progress made in developing a beam monitor with a sufficient dynamic range to allow for the detection of single particles, while still being able to act as a monitor at the clinical particle rates of the MedAustron treatment facility. The beam monitor is designed for integration into existing accelerators.

physics.acc-ph

A double multi-turn injection scheme for generating mixed helium and carbon ion beams at medical synchrotron facilities

The low relative charge-to-mass ratio offset of 0.065% between fully ionized helium-4 and carbon-12 ions enables simultaneous acceleration in hadron therapy synchrotrons. At the same energy per mass, helium ions exhibit a stopping range approximately three times greater than carbon ions. They can therefore be exploited for online range verification downstream of the patient during carbon ion beam irradiation. One possibility for creating this mixed beam is accelerating the two ion species sequentially through the LINAC and subsequently "mixing" them at injection energy in the synchrotron with a double multi-turn injection scheme. This work reports the first successful generation, acceleration, and extraction of a mixed helium and carbon ion beam using this double multi-turn injection scheme, which was achieved at the MedAustron therapy accelerator in Austria. A description of the double multi-turn injection scheme, particle tracking simulations, and details on the implementation at the MedAustron accelerator facility are presented and discussed. Finally, measurements of the mixed beam at delivery in the irradiation room using a radiochromic film and a low-gain avalanche diode (LGAD) detector are presented.

physics.acc-ph

Exploring Offline Pileup Correction to Improve the Accuracy of Microdosimetric Characterization in Clinical Ion Beams

Microdosimetry investigates the energy deposition of ionizing radiation at microscopic scales, beyond the assessment capabilities of macroscopic dosimetry. This contributes to an understanding of the biological response in radiobiology, radiation protection and radiotherapy. Microdosimetric pulse height spectra are usually measured using an ionization detector in a pulsed readout mode. This incorporates a charge-sensitive amplifier followed by a shaping network. At high particle rates, the pileup of multiple pulses leads to distortions in the recorded spectra. Especially for gas-based detectors, this is a significant issue, that can be reduced by using solid-state detectors with smaller cross-sectional areas and faster readout speeds. At particle rates typical for ion therapy, however, such devices will also experience pileup. Mitigation techniques often focus on avoiding pileup altogether, while post-processing approaches are rarely investigated. This work explores pileup effects in microdosimetric measurements and presents a stochastic resampling algorithm, allowing for offline simulation and correction of spectra. Initially it was developed for measuring neutron spectra with tissue equivalent proportional counters and is adapted for the use with solid-state microdosimeters in a clinical radiotherapy setting. The algorithm was tested on data acquired with solid-state microdosimeters at the MedAustron ion therapy facility. The successful simulation and reduction of pileup counts is achieved by establishing of a limited number of parameters for a given setup. The presented results illustrate the potential of offline correction methods in situations where a direct pileup-free measurement is currently not practicable.

physics.med-ph

Observation of Charge Enhancement in forward-biased neutron-irradiated 4H-SiC PiN Detectors in UV-TCT Measurements

Due to the increased commercial availability, wide-bandgap semiconductors and their radiation hardness have recently received increased interest from the particle physics community. 4H-Silicon Carbide (SiC), especially, is an attractive candidate for future radiation-hard detectors which do not require cooling. This paper investigates the radiation hardness of 4H-SiC p-in-n detectors irradiated up to $5\times 10^{15}$ $\text{n}_{\text{eq.}}/\text{cm}^2$ using UV-TCT. The samples have been operated in reverse and forward bias, which is possible due to the heavily decreased forward current after irradiation. Previous studies have already hinted at an excessive charge collection in forward bias, even exceeding a charge collection efficiency (CCE) of 100%. In this work, the excessive CCE in forward bias was shown to correlate heavily with the spatial profile of injected charge. For a sufficiently focused laser, the CCE starts to increase at high forward bias and even surpasses 100% instead of saturating as it does for a defocused laser beam. In reverse bias, the CCE was found to be independent of the beam spot size. For samples irradiated to high fluences ($\geq 1\times 10^{15}$ $\text{n}_{\text{eq.}}/\text{cm}^2$) the excessive CCE in forward bias is smaller and negligible at the highest fluences. Additionally, the CCE was observed to correlate to the rate of charge injection (laser pulses per second), with a logarithmic increase of the collected charge if a threshold of injected carrier density is exceeded. The mechanism of these effects is still an ongoing topic of study, however, the observations already pose implications for the accurate experimental characterization of irradiated SiC detectors.

physics.ins-det

TCAD Parameters for 4H-SiC: A Review

In this literature review we investigate the permittivity, density-of-state mass, band gap, impact ionization, charge carrier recombination, incomplete ionization and mobility in 4H silicon carbide. We provide a comprehensive overview over characterization methods, models and parameters to lower the entrance barrier for newcomers and allow a critical evaluation of common material property descriptions. We further highlight areas for future research by identifying gaps in the current knowledge base. For each investigated property we found a large amount of models and parameter sets based on measurements, calculations or fittings. With literal and/or graphical comparisons we reveal qualitative good agreement but also flawed data values, misinterpretations of research results and inconsistencies among multiple investigations, even those directly referencing each other. We identify parameter variations, e.g., due to temperature, with high impact that are rarely considered in 4H-SiC analyses and common values that are based on old research of deviating materials or properties. We further show the slow accommodation of recent research results within the scientific community and reveal missing characterization data but also insufficient models in state-of-the-art technology computer aided design (TCAD) tools. Overall, our review enables scientifically based decisions on 4H-SiC material parameters and unravels the demand for further investigations to validate commonly used values, confirm hypothesis and cover additional dependencies.

cond-mat.mtrl-sci

The European Strategy and Detector R&D Program

The latest update of the European Strategy for Particle Physics stimulated the preparation of the European Detector Roadmap document in 2021 by the European Committee for Future Accelerators ECFA. This roadmap, defined during a bottom-up process by the community, outlines nine technology domains for HEP instrumentation and pinpoints urgent R&D topics, known as Detector R&D Themes (DRDTs). Task forces were set for each domain, leading to Detector R&D Collaborations (DRDs), now hosted at CERN. After an intensive period over the last months, seven DRD collaborations have been established, which are now starting to set up their collaboration structures and begin to work. One is still in the preparation phase. In this publication, I will give an overview of the set-up process and the current status of all DRD collaborations covering detector developments in the field of gaseous detectors, noble liquid detectors for rare event searches, semiconductor detectors, photodetectors and concepts for particle ID, quantum sensors, calorimetry, electronics for HEP instrumentation and mechanical and integration aspects.

physics.ins-det

TCAD Simulations of Radiation Damage in 4H-SiC

To increase the scientific output of particle physics experiments, upgrades are underway at all major accelerator facilities to significantly improve the luminosity. Consequently, the solid-state detectors used in the experiments will exhibit more severe radiation-induced damage. To ensure sufficiently long sensor lifetimes, alternative materials to the established silicon sensors, with improved resilience to radiation, are investigated. For one of the promising candidate materials, silicon carbide, only recently a model describing the radiation damage in technology aided computer design (TCAD) simulations has been proposed. In this paper we present our latest achievements towards modeling radiation damage of 4H-SiC in TCAD tools. We first verify the utilized TCAD framework against published silicon data and then use it to approximate measurements of neutron-irradiated 4H-SiC particle detectors. We are able to confirm in simulations the measurement results, i.e., an almost flat capacitance as a function of bias voltage and a decreasing forward current with increasing particle fluence. Based on our simulations we are able to explain the latter by trapped charge carriers that create a space charge region within the device.

physics.ins-det