SearcharxivSearch

arXiv · 2608.03208

Spectacular - A Modular DAQ System for Microdosimetry

Abstract

Particle therapy using light ions like protons, helium ions or carbon ions enables precise tumor targeting with enhanced biological effectiveness while minimizing damage to healthy tissue. Successful treatment planning depends not only on the absorbed dose but also on quality of the radiation, as quantified by the linear energy transfer (LET). Microdosimetry provides a direct experimental determination of such quantities by measuring the energy deposited per incoming particle in micrometer-sized solid-state detectors representing the relevant biological scales. However, the small signal amplitudes and high particle rates in therapeutic ion beams challenge existing readout systems, which are not sufficiently optimized for reliable operation with respect to pileup and signal-to-noise ratio (SNR). To address this, a modular data acquisition (DAQ) system was developed to accelerate the design of custom readout electronics and sensor characterization in microdosimetry and related spectroscopic applications. Centered around a Xilinx Zynq system-on-chip, it combines real-time processing, high-bandwidth streaming, and high-resolution digitization (16 bit at 100 MSas$^{-1}$) to enable advanced digital signal processing. The platform integrates programmable power supplies, a bias-voltage filter, test-pulse generators, and flexible I/O. Detector and preamplifier front-ends are hosted on interchangeable daugtherboards connected via a standardized interface, allowing different hardware configurations and readout algorithms to be evaluated on the same platform. The Spectacular DAQ system was successfully tested at the MedAustron ion therapy facility with custom charge-sensitive amplifiers and a diamond microdosimeter. First results demonstrate the feasibility and provide a proof-of-concept for potential future applications in clinical practice.

Explore related subjects

Keep this discovery

BibTeXRIS

Matthias Knopf, Simon Waid, Daniel Radmanovac, Sebastian Onder, Richard Thalmeier, Peter Fischer, Stefan Gundacker, Claudio Verona, Edoardo Domenicone, Thomas Bergauer, Albert Hirtl. 2026-08-04. Spectacular - A Modular DAQ System for Microdosimetry. https://arxiv.org/abs/2608.03208

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det