Searcharxiv⌕ Search

arXiv subjects

Thomas Bergauer

Publications and source records attributed to Thomas Bergauer.

33 records · Page 2Linked to original sources

The European Strategy and Detector R&D Program

The latest update of the European Strategy for Particle Physics stimulated the preparation of the European Detector Roadmap document in 2021 by the European Committee for Future Accelerators ECFA. This roadmap, defined during a bottom-up process by the community, outlines nine technology domains for HEP instrumentation and pinpoints urgent R&D topics, known as Detector R&D Themes (DRDTs). Task forces were set for each domain, leading to Detector R&D Collaborations (DRDs), now hosted at CERN. After an intensive period over the last months, seven DRD collaborations have been established, which are now starting to set up their collaboration structures and begin to work. One is still in the preparation phase. In this publication, I will give an overview of the set-up process and the current status of all DRD collaborations covering detector developments in the field of gaseous detectors, noble liquid detectors for rare event searches, semiconductor detectors, photodetectors and concepts for particle ID, quantum sensors, calorimetry, electronics for HEP instrumentation and mechanical and integration aspects.

physics.ins-det↗

TCAD Simulations of Radiation Damage in 4H-SiC

To increase the scientific output of particle physics experiments, upgrades are underway at all major accelerator facilities to significantly improve the luminosity. Consequently, the solid-state detectors used in the experiments will exhibit more severe radiation-induced damage. To ensure sufficiently long sensor lifetimes, alternative materials to the established silicon sensors, with improved resilience to radiation, are investigated. For one of the promising candidate materials, silicon carbide, only recently a model describing the radiation damage in technology aided computer design (TCAD) simulations has been proposed. In this paper we present our latest achievements towards modeling radiation damage of 4H-SiC in TCAD tools. We first verify the utilized TCAD framework against published silicon data and then use it to approximate measurements of neutron-irradiated 4H-SiC particle detectors. We are able to confirm in simulations the measurement results, i.e., an almost flat capacitance as a function of bias voltage and a decreasing forward current with increasing particle fluence. Based on our simulations we are able to explain the latter by trapped charge carriers that create a space charge region within the device.

physics.ins-det↗

Measurement of the electron-hole pair creation energy in a 4H-SiC p-n diode

For 4H silicon carbide (4H-SiC), the values for the electron-hole pair creation energy $ε_{\text{i}}$ published in the literature vary significantly. This work presents an experimental determination of $ε_{\text{i}}$ using $50$ $μ$m 4H-SiC p-n diodes designed for particle detection in high-energy physics. The detector response was measured for $α$ particles between 4.2 MeV and 5.6 MeV for 4H-SiC and a silicon reference device. Different $α$ energies were obtained by using multiple nuclides and varying the effective air gap between the $α$ source and the detector. The energy deposited in the detectors was determined using a Monte Carlo simulation, taking into account the device cross-sections. A linear fit of the detector response to the deposited energy yields $ε_{\text{i}} = (7.83 \pm 0.02)\;\text{eV}$, which agrees well with the most recent literature. For the 4H-SiC detectors, a linewidth of 28 keV FWHM was achieved, corresponding to an energy resolution of 0.5\%.

physics.ins-det↗

SiC Based Beam Monitoring System for Particle Rates from kHz to GHz

The extremely low dark current of silicon carbide (SiC) detectors, even after high-fluence irradiation, was utilized to develop a beam monitoring system for a wide range of particle rates, i.e., from the kHz to the GHz regime. The system is completely built from off-the-shelve components and is focused on compactness and simple deployment. Beam tests using a 50 um thick SiC detector reveal, that for low fluences, single particles can be detected and counted. For higher fluences, beam properties were extracted from beam cross sections using a silicon strip detector. Overall accurate results were achieved up to a particle rate of 109 particles per second.

physics.ins-det↗

Pulsed RF Knock-Out Extraction: A Potential Enabler for FLASH Hadrontherapy in the Bragg Peak

One challenge on the path to delivering FLASH-compatible beams with a synchrotron is facilitating an accurate dose-control for the required ultra-high dose rates. We propose the use of pulsed RFKO extraction instead of continuous beam delivery as a way to control the dose delivered per Voxel. In a first feasibility test dose rates in pulses of up to 600 Gy/s were observed, while the granularity at which the dose was delivered is expected to be well below 0.5 Gy.

physics.med-ph↗

First experimental time-of-flight-based proton radiography using low gain avalanche diodes

Ion computed tomography (iCT) is an imaging modality for the direct determination of the relative stopping power (RSP) distribution within a patient's body. Usually, this is done by estimating the path and energy loss of ions traversing the scanned volume via a tracking system and a separate residual energy detector. This study, on the other hand, introduces the first experimental study of a novel iCT approach based on time-of-flight (TOF) measurements, the so-called Sandwich TOF-iCT concept, which in contrast to any other iCT system, does not require a residual energy detector for the RSP determination. A small TOF-iCT demonstrator was built based on low gain avalanche diodes (LGAD), which are 4D-tracking detectors that allow to simultaneously measure the particle position and time-of-arrival with a precision better than 100um and 100ps, respectively. Using this demonstrator, the material and energy-dependent TOF was measured for several homogeneous PMMA slabs in order to calibrate the acquired TOF against the corresponding water equivalent thickness (WET). With this calibration, two proton radiographs (pRad) of a small aluminium stair phantom were recorded at MedAustron using 83 and 100.4MeV protons. Due to the simplified WET calibration models used in this very first experimental study of this novel approach, the difference between the measured and theoretical WET ranged between 37.09 and 51.12%. Nevertheless, the first TOF-based pRad was successfully recorded showing that LGADs are suitable detector candidates for TOF-iCT. While the system parameters and WET estimation algorithms require further optimization, this work was an important first step to realize Sandwich TOF-iCT. Due to its compact and cost-efficient design, Sandwich TOF-iCT has the potential to make iCT more feasible and attractive for clinical application, which, eventually, could enhance the treatment planning quality.

physics.med-ph↗

Neutron Radiation induced Effects in 4H-SiC PiN Diodes

Silicon carbide (SiC) is a wide band gap semiconductor and an attractive candidate for applications in harsh environments such as space, fusion, or future high luminosity colliders. Due to the large band gap, the leakage currents in SiC devices are extremely small, even after irradiation to very high fluences, enabling operation without cooling and at high temperatures. This study investigates the effect of neutron irradiation on 50$μ$m p-n 4H-SiC diodes using current-voltage, capacitance-voltage, and charge collection efficiency (CCE) measurements up to neutron fluences of $1\times 10^{16}$ n$_{\text{eq}}$/cm$^2$. The leakage currents of the investigated devices remained extremely small, below 10 pA at 1.1 kV reverse bias. In the forward bias, a remarkable drop of the current was observed, which was attributed to an increased epi resistivity due to compensation of the epi layer doping by deep-level defects. The CCE was evaluated for alpha particles from a radioactive source, a 62.4 MeV proton beam at the MedAustron ion therapy center and using UV-TCT. The charge collection efficiency in reverse bias was shown to scale directly with the 1 MeV equivalent fluence $Φ_{\text{eq}}$ as $\text{CCE} \propto Φ_{\text{eq}}^{-0.63\pm0.01}$. A CCE better than 50% was able to be obtained for fluences up to $1 \times 10^{15}$ n$_{\text{eq}}$/cm$^2$. Because of the low currents in the forward direction, particle detection was also possible in forward bias, where the CCE was found to be increased relative to reverse bias. Furthermore, a significant dependency on the amount of injected charge was observed, with the CCE surpassing 100% in alpha and UV-TCT measurements, requiring further systematic investigation.

physics.ins-det↗

RD50-MPW3: A fully monolithic digital CMOS sensor for future tracking detectors

The CERN-RD50 CMOS working group develops the RD50-MPWseries of monolithic high-voltage CMOS pixel sensors for potential use in future high luminosity experiments such as the HL-LHC and FCC-hh. In this contribution, the design of the latest prototype in this series, RD50-MPW3, is presented. An overview of its pixel matrix and digital readout periphery is given, with discussion of the new structures implemented in the chip and the problems they aim to solve. The main analog and digital features of the sensor are already tested and initial laboratory characterisation of the chip is presented.

physics.ins-det↗

Readout system and testbeam results of the RD50-MPW2 HV-CMOS pixel chip

The RD50-CMOS group aims to design and study High Voltage CMOS (HVCMOS) chips for use in a high radiation environment. Currently, measurements are performed on RD50-MPW2 chip, the second prototype developed by this group. The active matrix of the prototype consists of 8x8 pixels with analog front end. Details of the analog front end and simulations have been already published earlier. This contribution focuses on the Caribou based readout system of the active matrix. Each pixel of the active matrix can be readout one after the other. Relevant aspects of hardware, firmware and software are introduced. As a first stage, firmware for a standalone setup is introduced and details on data flow are given. Afterwards, a second stage of the firmware capable of synchronizing with other detectors and accepting triggers is presented, focusing on operation of the chip in combination with a tracking telescope to measure efficiency and residuals.

physics.ins-det↗

Performance of neutron-irradiated 4H-Silicon Carbide diodes subjected to Alpha radiation

The unique electrical and material properties of 4H-silicon-carbide (4H-SiC) make it a promising candidate material for high rate particle detectors. In contrast to the ubiquitously used silicon (Si), 4H-SiC offers a higher carrier saturation velocity and larger breakdown voltage, enabling a high intrinsic time resolution and mitigating pile-up effects. Additionally, as radiation hardness requirements grow more demanding, wide-bandgap materials such as 4H-SiC could offer better performance. In this work, the detector performance of 50 micron thick 4H-SiC p-in-n planar pad sensors was investigated at room temperature, using an 241Am alpha source at reverse biases of up to 1100 V. Samples subjected to neutron irradiation with fluences of up to 1e16/cm^2 were included in the study in order to quantify the radiation hardness properties of 4H-SiC. The obtained results are compared to previously performed UV-TCT studies. Samples exhibit a drop in charge collection efficiency (CCE) with increasing irradiation fluence, partially compensated at high reverse bias voltages far above full depletion voltage. A plateau of the collected charges is observed in accordance with the depletion of the volume the alpha particles penetrate for an unirradiated reference detector. For the neutron-irradiated samples, such a plateau only becomes apparent at higher reverse bias. For the highest investigated fluence, CCE behaves almost linearly with increasing reverse bias. Compared to UV-TCT measurements, the reverse bias required to deplete a sensitive volume covering full energy deposition is lower, due to the small penetration depth of the alpha particles. At the highest reverse bias, the measured CCE values agree well with earlier UV-TCT studies, with discrepancies between 1% and 5%.

physics.ins-det↗

Novel ion imaging concept based on time-of-flight measurements with low gain avalanche detectors

Treatment planning in ion beam therapy requires accurate knowledge of the relative stopping power (RSP) distribution within the patient. Currently, RSP maps are obtained via conventional x-ray computed tomography (CT) by converting the measured attenuation coefficients of photons into RSP values for ions. Alternatively, to avoid conversion errors that are inherent to this method, ion computed tomography (iCT) can be used since it allows determining the RSP directly. In typical iCT systems, which usually consist of a tracking system and a separate residual energy detector, the RSP is obtained by measuring the particle trajectory and the corresponding water equivalent path length (WEPL) of single ions travelling through the patient. Within this work, we explore a novel iCT approach which does not require a residual energy detector. Instead, the WEPL is estimated indirectly by determining the change in time of flight (TOF) due to the energy loss along the ion's path. For this purpose, we have created a Geant4 model of a TOF-iCT system based on low gain avalanche detectors (LGADs), which are fast 4D-tracking detectors that can measure the time of arrival and position of individual particles with high spatial and time precision. To assess the performance of this TOF-iCT concept, we determined the RSP resolution and accuracy for different system settings using the Catphan CTP404 sensitometry phantom. Within the set of investigated system parameters, the lower limit of the RSP accuracy was found at 0.91%, demonstrating the proof-of-principle of this novel TOF-iCT concept. The main advantage of using this approach is that it could potentially facilitate clinical integration due to its compact design, which, however, requires experimental verification and an improvement of the current WEPL calibration procedure.

physics.med-ph↗

4H-Silicon Carbide as particle detector for high-intensity ion beams

In ion cancer therapy, high-intensity ion beams are used to treat tumors by taking advantage of the Bragg-Peak. Typical ion therapy centers use particle rates up to $10^{10}$ ions/second for treatment. On the other hand, such intensities are often too high when using these beamlines for particle physics experiments or as a test-beam environment in general. The project presented here aims to develop a beam position and intensity monitor, to cover a wide intensity range from a few Hz up to GHz rates, as used in clinical settings. Silicon carbide (SiC) is an attractive detector material for this application because it combines potential high radiation hardness with high thermal conductivity to avoid cooling. Moreover, its high electron saturation velocity allows very fast signals to mitigate pile-ups. However, some special properties of the material like different crystal polytypes have to be considered. In this paper, measurements on both a pad and a micro-strip SiC sensor prototype of 4H lattice geometry are shown. The sensors were tested in the laboratory using radioactive sources and with a proton beam in a wide intensity range (kHz-GHz) and with different energies (60-800 MeV) available at MedAustron, an ion cancer therapy center located in Austria. The measurements show that MIP particles cannot be detected reliably with the used discrete electronics setup in combination with the single-channel sensor. However, the strip sensor combined with an ASIC-based readout electronics from the CMS/Belle-II experiments allows to recover a certain part of the signal. This makes it possible to determine the ionization energy and average number of electron/hole pairs generated in the studied sensor samples.

physics.ins-det↗

Feasibility study of a proton CT system based on 4D-tracking and residual energy determination via time-of-flight

For dose calculations in ion beam therapy, it is vital to accurately determine the relative stopping power (RSP) distribution within the treated volume. Currently, RSP values are extrapolated from Hounsfield units (HU), measured with x-ray computed tomography (CT), which entails RSP inaccuracies due to conversion errors. A suitable method to improve the treatment plan accuracy is proton computed tomography (pCT). A typical pCT system consists of a tracking system and a separate residual energy (or range) detector to measure the RSP distribution directly. This paper introduces a novel pCT system based on a single detector technology, namely low gain avalanche detectors (LGADs). LGADs are fast 4D-tracking detectors, which can be used to simultaneously measure the particle position and time with precise timing and spatial resolution. In contrast to standard pCT systems, the residual energy is determined via a time-of-flight (TOF) measurement between different 4D-tracking stations. The design parameters for a realistic proton computed tomography system based on 4D-tracking detectors were studied and optimized using Monte Carlo simulations. The RSP accuracy and RSP resolution were measured inside the inserts of the CTP404 phantom to estimate the performance of the pCT system. After introducing a dedicated calibration procedure for the TOF calorimeter, RSP accuracies < 0.6 % could be achieved. Furthermore, the design parameters with the strongest impact on the RSP resolution were identified and a strategy to improve RSP resolution is proposed.

physics.med-ph↗

A Proton Computed Tomography Demonstrator for Stopping Power Measurements

Particle therapy is an established method to treat deep-seated tumours using accelerator-produced ion beams. For treatment planning, the precise knowledge of the relative stopping power (RSP) within the patient is vital. Conversion errors from x-ray computed tomography (CT) measurements to RSP introduce uncertainties in the applied dose distribution. Using a proton computed tomography (pCT) system to measure the SP directly could potentially increase the accuracy of treatment planning. A pCT demonstrator, consisting of double-sided silicon strip detectors (DSSD) as tracker and plastic scintillator slabs coupled to silicon photomultipliers (SiPM) as a range telescope, was developed. After a significant hardware upgrade of the range telescope, a 3D tomogram of an aluminium stair phantom was recorded at the MedAustron facility in Wiener Neustadt, Austria. In total, 80 projections with 6.5x10^5 primary events were acquired and used for the reconstruction of the RSP distribution in the phantom. After applying a straight-line approximation for the particle path inside the phantom, the most probable value (MPV) of the RSP distribution could be measured with an accuracy of 0.59%. The RSP resolution inside the phantom was only 9.3% due to a limited amount of projections and measured events per projection.

physics.med-ph↗

Commissioning of low particle flux for proton beams at MedAustron

MedAustron is a synchrotron-based particle therapy centre located in Wiener Neustadt, Austria. It features three irradiation rooms for particle therapy, where proton beams with energies up to 252.7 MeV and carbon ions of up to 402.8 MeV/u are available for cancer treatment. In addition to the treatment rooms, MedAustron features a unique beamline exclusively for non-clinical research (NCR). This research beamline is also commissioned for proton energies up to 800 MeV, while available carbon ion energies correspond to the ones available in the clinical treatment rooms. Based on the requirements for particle therapy, all irradiation rooms offer particle rates of up to 10^9 particles/s for protons and 10^7 particles/s for carbon ions. However, for research purposes, lower particle fluxes are required and were therefore commissioned for the NCR beamline. Three particle flux settings with particle rates ranging from ~2.4x10^3 particles/s to ~5.2x10^6 particles/s were established for seven proton energies below 252.7 MeV. In addition to the particle rate, the spot sizes and beam energies were measured for these settings. Furthermore, three low flux settings for 800 MeV protons with particle rates ranging from ~2x10^3 particles/s to ~1.3x10^6 particles/s were commissioned. Since the commissioned low flux settings are in a regime well below the limits of the available standard beam diagnostics, setting up the beam under these new operational conditions entirely relied on the use of external detectors. Furthermore, a beam position measurement based alignment without using the standard beam profile monitors was performed for 800 MeV protons.

physics.acc-ph↗