Searcharxiv⌕ Search

arXiv subjects

Wenbo Ma

Publications and source records attributed to Wenbo Ma.

At least 37 records · Page 2Linked to original sources

Constraints on the axial-vector and pseudo-scalar mediated WIMP-nucleus interactions from PandaX-4T experiment

We present the constraints on the axial-vector and pseudo-scalar mediated WIMP-nucleus interactions from the PandaX-4T experiment, using the data set corresponding to a total exposure of 0.63~tonne$\cdot$year. No significant signal excess is observed, and the most stringent upper limits to date on the spin-dependent WIMP-neutron scattering cross section are set at 90\% confidence level with the minimum WIMP-neutron scattering cross section of 5.8$\times 10^{-42}$\si{\cm^{2}} for WIMP mass of 40~\si{\GeV/}$c^2$. Exclusion limits on the axial-vector and pseudo-scalar simplified models are also derived.

hep-ex↗

Measurement of Solar $pp$ Neutrino Flux using Electron Recoil Data from PandaX-4T Commissioning Run

The proton-proton ($pp$) fusion chain dominates the neutrino production from the Sun. The uncertainty of the predicted $pp$ neutrino flux is at the sub-percent level, whereas that of the best measurement is $\mathcal{O}(10\%)$. In this paper, we present the first result to measure the solar $pp$ neutrinos in the electron recoil energy range from 24 to 144 keV, using the PandaX-4T commissioning data with 0.63 tonne$\times$year exposure. The $pp$ neutrino flux is determined to be $(8.0 \pm 3.9 \,{\rm{(stat)}} \pm 10.0 \,{\rm{(syst)}} )\times 10^{10}\, $$\rm{s}^{-1} \rm{cm}^{-2}$, consistent with Standard Solar Model and existing measurements, corresponding to a flux upper limit of $23.3\times 10^{10}\, $$\rm{s}^{-1} \rm{cm}^{-2}$ at 90\% C.L..

hep-ex↗

An alkali-referenced vector spectrum analyzer for visible-light integrated photonics

Integrated photonics has reformed our information society by offering on-chip optical signal synthesis, processing and detection with reduced size, weight and power consumption. As such, it has been successfully established in the near-infrared (NIR) telecommunication bands. With the soaring demand in miniaturized systems for biosensing, quantum information and transportable atomic clocks, extensive endeavors have been stacked on translating integrated photonics into the visible spectrum, i.e. visible-light integrated photonics. Various innovative visible-light integrated devices have been demonstrated, such as lasers, frequency combs, and atom traps, highlighting the capacity and prospect to create chip-based optical atomic clocks that can make timing and frequency metrology ubiquitous. A pillar to the development of visible-light integrated photonics is characterization techniques featuring high frequency resolution and wide spectral coverage, which however remain elusive. Here, we demonstrate a vector spectrum analyzer (VSA) for visible-light integrated photonics, offering spectral bandwidth from 766 to 795 nm and frequency resolution of 415 kHz. The VSA is rooted on a widely chirping, high-power, narrow-linewidth, mode-hop-free laser around 780 nm, which is frequency-doubled from the near-infrared via an efficient, broadband CPLN waveguide. The VSA is further referenced to hyperfine structures of rubidium and potassium atoms, enabling 8.1 MHz frequency accuracy. We apply our VSA to showcase the characterization of loss, dispersion and phase response of passive integrated devices, as well as densely spaced spectra of mode-locked lasers. Combining operation in the NIR and visible spectra, our VSA allows characterization bandwidth exceeding an octave and can be an invaluable diagnostic tool for spectroscopy, nonlinear optical processing, imaging and quantum interfaces to atomic devices.

physics.optics↗

Signal Response Model in PandaX-4T

PandaX-4T experiment is a deep-underground dark matter direct search experiment that employs a dual-phase time projection chamber with a sensitive volume containing 3.7 tonne of liquid xenon. The detector of PandaX-4T is capable of simultaneously collecting the primary scintillation and ionization signals, utilizing their ratio to discriminate dark matter signals from background sources such as gamma rays and beta particles. The signal response model plays a crucial role in interpreting the data obtained by PandaX-4T. It describes the conversion from the deposited energy by dark matter interactions to the detectable signals within the detector. The signal response model is utilized in various PandaX-4T results. This work provides a comprehensive description of the procedures involved in constructing and parameter-fitting the signal response model for the energy range of approximately 1 keV to 25 keV for electronic recoils and 6 keV to 90 keV for nuclear recoils. It also covers the signal reconstruction, selection, and correction methods, which are crucial components integrated into the signal response model.

physics.ins-det↗

Waveform Simulation in PandaX-4T

Signal reconstruction through software processing is a crucial component of the background and signal models in the PandaX-4T experiment, which is a multi-tonne dark matter direct search experiment. The accuracy of signal reconstruction is influenced by various detector artifacts, including noise, dark count of photomultiplier, impurity photoionization in the detector, and other relevant considerations. In this study, we present a detailed description of a semi-data-driven approach designed to simulate the signal waveform. This work provides a reliable model for the efficiency and bias of the signal reconstruction in the data analysis of PandaX-4T. By comparing critical variables which relate to the temporal shape and hit pattern of the signals, we demonstrate a good agreement between the simulation and data.

hep-ex↗

Searching for Two-Neutrino and Neutrinoless Double Beta Decay of $^{134}$Xe with the PandaX-4T Experiment

$^{134}$Xe is a candidate isotope for neutrinoless double beta decay~($0νββ$) search. In addition, the two-neutrino case ($2νββ$) allowed by the Standard Model of particle physics has not yet been observed. Utilizing the 10.4% of $^{134}$Xe in the natural xenon in the PandaX-4T detector and its first 94.9-day exposure, we have established the most stringent constraints on $2νββ$ and $0νββ$ of $^{134}$Xe half-lives, with limits of $2.8\times10^{22}$ yr and $3.0\times10^{23}$ yr at 90% confidence level, respectively. The $2νββ$ ($0νββ$) limit surpasses the previously reported best result by a factor of 32 (2.7), highlighting the potential of large monolithic natural xenon detectors.

nucl-ex↗

Radon Removal Commissioning of the PandaX-4T Cryogenic Distillation System

The PandaX-4T distillation system, designed for the removal of krypton and radon from xenon, is evaluated for its radon removal efficiency using a $^{222}$Rn source during the online distillation process. The PandaX-4T dark matter detector is employed to monitor the temporal evolution of radon activity. To determine the radon reduction factor, the experimental data of radon atoms introduced into and bypassed the distillation system is compared. The results indicate that the PandaX-4T distillation system achieves a radon reduction factor exceeding 190 at the flow rate of 10 slpm and the reflux ratio of 1.44. Gas-only online distillation process of a flow rate of 20 slpm is also conducted without observing significant reduction of radon levels in the detector. This observation suggests that the migration flow of radon atoms from the liquid phase to the gas phase is limited, and the flow rate of gas circulation and duration of the process are insignificant compared to the total xenon mass of 5.6 tons in the detector. This study provides the experimental data to support the efficient removal of radon at $\sim$Bq level using the PandaX-4T distillation system, which is the prerequisite of the radon background control in the detector. The further operation with higher flow rate will be applied for the upcoming science run in PandaX-4T.

physics.ins-det↗

Detecting Neutrinos from Supernova Bursts in PandaX-4T

Neutrinos from core-collapse supernovae are essential for the understanding of neutrino physics and stellar evolution. The dual-phase xenon dark matter detectors can provide a way to track explosions of galactic supernovae by detecting neutrinos through coherent elastic neutrino-nucleus scatterings. In this study, a variation of progenitor masses as well as explosion models are assumed to predict the neutrino fluxes and spectra, which result in the number of expected neutrino events ranging from 6.6 to 13.7 at a distance of 10 kpc over a 10-second duration with negligible backgrounds at PandaX-4T. Two specialized triggering alarms for monitoring supernova burst neutrinos are built. The efficiency of detecting supernova explosions at various distances in the Milky Way is estimated. These alarms will be implemented in the real-time supernova monitoring system at PandaX-4T in the near future, providing the astronomical communities with supernova early warnings.

hep-ex↗

Drone-Delivery Network for Opioid Overdose -- Nonlinear Integer Queueing-Optimization Models and Methods

We propose a new stochastic emergency network design model that uses a fleet of drones to quickly deliver naxolone in response to opioid overdoses. The network is represented as a collection of M/G/K queuing systems in which the capacity K of each system is a decision variable and the service time is modelled as a decision-dependent random variable. The model is an optimization-based queuing problem which locates fixed (drone bases) and mobile (drones) servers and determines the drone dispatching decisions, and takes the form of a nonlinear integer problem, which is intractable in its original form. We develop an efficient reformulation and algorithmic framework. Our approach reformulates the multiple nonlinearities (fractional, polynomial, exponential, factorial terms) to give a mixed-integer linear programming (MILP) formulation. We demonstrate its generalizablity and show that the problem of minimizing the average response time of a network of M/G/K queuing systems with unknown capacity K is always MILP-representable. We design two algorithms and demonstrate that the outer approximation branch-and-cut method is the most efficient and scales well. The analysis based on real-life overdose data reveals that drones can in Virginia Beach: 1) decrease the response time by 78%, 2) increase the survival chance by 432%, 3) save up to 34 additional lives per year, and 4) provide annually up to 287 additional quality-adjusted life years.

math.OC↗

Search for Dark-Matter-Nucleon Interactions with a Dark Mediator in PandaX-4T

We report results of a search for dark-matter-nucleon interactions via a dark mediator using optimized low-energy data from the PandaX-4T liquid xenon experiment. With the ionization-signal-only data and utilizing the Migdal effect, we set the most stringent limits on the cross section for dark matter masses ranging from 30~$\rm{MeV/c^2}$ to 2~$\rm{GeV/c^2}$. Under the assumption that the dark mediator is a dark photon that decays into scalar dark matter pairs in the early Universe, we rule out significant parameter space of such thermal relic dark-matter model.

hep-ex↗

Multi-Agent Search for a Moving and Camouflaging Target

In multi-agent search planning for a randomly moving and camouflaging target, we examine heterogeneous searchers that differ in terms of their endurance level, travel speed, and detection ability. This leads to a convex mixed-integer nonlinear program, which we reformulate using three linearization techniques. We develop preprocessing steps, outer approximations via lazy constraints, and bundle-based cutting plane methods to address large-scale instances. Further specializations emerge when the target moves according to a Markov chain. We carry out an extensive numerical study to show the computational efficiency of our methods and to derive insights regarding which approach should be favored for which type of problem instance.

math.OC↗

Search for light dark matter from atmosphere in PandaX-4T

We report a search for light dark matter produced through the cascading decay of $η$ mesons, which are created as a result of inelastic collisions between cosmic rays and Earth's atmosphere. We introduce a new and general framework, publicly accessible, designed to address boosted dark matter specifically, with which a full and dedicated simulation including both elastic and quasi-elastic processes of Earth attenuation effect on the dark matter particles arriving at the detector is performed. In the PandaX-4T commissioning data of 0.63 tonne$\cdot$year exposure, no significant excess over background is observed. The first constraints on the interaction between light dark matter generated in the atmosphere and nucleus through a light scalar mediator are obtained. The lowest excluded cross-section is set at $5.9 \times 10^{-37}{\rm cm^2}$ for dark matter mass of $0.1$ MeV$/c^2$ and mediator mass of 300 MeV$/c^2$. The lowest upper limit of $η$ to dark matter decay branching ratio is $1.6 \times 10^{-7}$.

hep-ex↗

A Search for Light Fermionic Dark Matter Absorption on Electrons in PandaX-4T

We report a search on a sub-MeV fermionic dark matter absorbed by electrons with an outgoing active neutrino using the 0.63 tonne-year exposure collected by PandaX-4T liquid xenon experiment. No significant signals are observed over the expected background. The data are interpreted into limits to the effective couplings between such dark matter and electrons. For axial-vector or vector interactions, our sensitivity is competitive in comparison to existing astrophysical bounds on the decay of such dark matter into photon final states. In particular, we present the first direct detection limits for an axial-vector (vector) interaction which are the strongest in the mass range from 25 to 45 (35 to 50) keV/c$^2$.

hep-ex↗

A First Search for Solar $^8$B Neutrino in the PandaX-4T Experiment using Neutrino-Nucleus Coherent Scattering

A search for interactions from solar $^8$B neutrinos elastically scattering off xenon nuclei using PandaX-4T commissioning data is reported. The energy threshold of this search is further lowered compared with the previous search for dark matter, with various techniques utilized to suppress the background that emerges from data with the lowered threshold. A blind analysis is performed on the data with an effective exposure of 0.48 tonne$\cdot$year, and no significant excess of events is observed. Among results obtained using the neutrino-nucleus coherent scattering, our results give the best constraint on the solar $^8$B neutrino flux. We further provide a more stringent limit on the cross section between dark matter and nucleon in the mass range from 3 to 9 GeV/c$^2$.

hep-ex↗

VL-NMS: Breaking Proposal Bottlenecks in Two-Stage Visual-Language Matching

The prevailing framework for matching multimodal inputs is based on a two-stage process: 1) detecting proposals with an object detector and 2) matching text queries with proposals. Existing two-stage solutions mostly focus on the matching step. In this paper, we argue that these methods overlook an obvious \emph{mismatch} between the roles of proposals in the two stages: they generate proposals solely based on the detection confidence (i.e., query-agnostic), hoping that the proposals contain all instances mentioned in the text query (i.e., query-aware). Due to this mismatch, chances are that proposals relevant to the text query are suppressed during the filtering process, which in turn bounds the matching performance. To this end, we propose VL-NMS, which is the first method to yield query-aware proposals at the first stage. VL-NMS regards all mentioned instances as critical objects, and introduces a lightweight module to predict a score for aligning each proposal with a critical object. These scores can guide the NMS operation to filter out proposals irrelevant to the text query, increasing the recall of critical objects, resulting in a significantly improved matching performance. Since VL-NMS is agnostic to the matching step, it can be easily integrated into any state-of-the-art two-stage matching methods. We validate the effectiveness of VL-NMS on two multimodal matching tasks, namely referring expression grounding and image-text matching. Extensive ablation studies on several baselines and benchmarks consistently demonstrate the superiority of VL-NMS.

cs.CV↗

Measurement of Double Beta Decay Half-life of $^{136}$Xe with the PandaX-4T Detector

Precise measurement of two-neutrino double beta decay (DBD) half-life is an important step for the searches of Majorana neutrinos with neutrinoless double beta decay. We report the measurement of DBD half-life of $^{136}$Xe using the PandaX-4T dual-phase Time Projection Chamber (TPC) with 3.7-tonne natural xenon and the first 94.9-day physics data release. The background model in the fiducial volume is well constrained in situ by events in the outer active region. With a $^{136}$Xe exposure of 15.5 kg-year, we establish the half-life as $2.27 \pm 0.03 (stat.)\pm 0.10 (syst.)\times 10^{21}$ years. This is the first DBD half-life measurement with natural xenon and demonstrates the physics capability of a large-scale liquid xenon TPC in the field of rare event searches.

nucl-ex↗

First search for the absorption of fermionic dark matter with the PandaX-4T experiment

Compared with the signature of dark matter elastic scattering off nuclei, the absorption of fermionic dark matter by nuclei opens up a new searching channel for light dark matter with a characteristic monoenergetic signal. In this Letter, we explore the $95.0$-day data from the PandaX-4T commissioning run and report the first dedicated searching results of the fermionic dark matter absorption signal through a neutral current process. No significant signal was found, and the lowest limit on the dark matter-nucleon interaction cross section is set to be $1.5\times10^{-50}$ cm$^2$ for a fermionic dark matter mass of $40$ MeV/$c^2$ with 90\% confidence level.

hep-ex↗

Design and Operation of the PandaX-4T High Speed Ultra-high Purity Xenon Recuperation System

In order to recuperate the ultra-high purity xenon from PandaX-4T dark matter detector to high-pressure gas cylinders in emergency or at the end-of-run situation, a high speed ultra-high purity xenon recuperation system is designed and developed. This system includes a diaphragm pump, the heat management system, the main recuperation pipeline, the reflux pipeline, the auxiliary recuperation pipeline and the automatic control system. The liquid xenon in the detector is vaporized by the heat management system, and the gaseous xenon is compressed to 6 MPa at the flow rate of 200 standard litres per minute (SLPM) using the diaphragm compressor. The high-pressure xenon is filled into 128 gas cylinders via the main recuperation pipeline. During the recuperation, the low pressure and temperature conditions of 2 ~ 3 atmospheres and 178 ~ 186.5 K in PandaX-4T dark matter detector are kept by the cooperation of the main recuperation pipeline, reflux pipeline and the auxiliary recuperation pipeline to guarantee the safety, and the purity of the recuperated xenon gas is measured to ensure no contamination happened. The development of the high speed ultra-high purity xenon recuperation system is important for the operation of large-scale dark matter detectors with the requirements of strict temperature and pressure environment and low background.

physics.ins-det↗