SearcharxivSearch

arXiv · 2406.13323

An alkali-referenced vector spectrum analyzer for visible-light integrated photonics

Abstract

Integrated photonics has reformed our information society by offering on-chip optical signal synthesis, processing and detection with reduced size, weight and power consumption. As such, it has been successfully established in the near-infrared (NIR) telecommunication bands. With the soaring demand in miniaturized systems for biosensing, quantum information and transportable atomic clocks, extensive endeavors have been stacked on translating integrated photonics into the visible spectrum, i.e. visible-light integrated photonics. Various innovative visible-light integrated devices have been demonstrated, such as lasers, frequency combs, and atom traps, highlighting the capacity and prospect to create chip-based optical atomic clocks that can make timing and frequency metrology ubiquitous. A pillar to the development of visible-light integrated photonics is characterization techniques featuring high frequency resolution and wide spectral coverage, which however remain elusive. Here, we demonstrate a vector spectrum analyzer (VSA) for visible-light integrated photonics, offering spectral bandwidth from 766 to 795 nm and frequency resolution of 415 kHz. The VSA is rooted on a widely chirping, high-power, narrow-linewidth, mode-hop-free laser around 780 nm, which is frequency-doubled from the near-infrared via an efficient, broadband CPLN waveguide. The VSA is further referenced to hyperfine structures of rubidium and potassium atoms, enabling 8.1 MHz frequency accuracy. We apply our VSA to showcase the characterization of loss, dispersion and phase response of passive integrated devices, as well as densely spaced spectra of mode-locked lasers. Combining operation in the NIR and visible spectra, our VSA allows characterization bandwidth exceeding an octave and can be an invaluable diagnostic tool for spectroscopy, nonlinear optical processing, imaging and quantum interfaces to atomic devices.

Explore related subjects

Keep this discovery

BibTeXRIS

Baoqi Shi, Ming-Yang Zheng, Yunkai Zhao, Yi-Han Luo, Jinbao Long, Wei Sun, Wenbo Ma, Xiu-Ping Xie, Lan Gao, Chen Shen, Anting Wang, Wei Liang, Qiang Zhang, Junqiu Liu. 2024-06-19. An alkali-referenced vector spectrum analyzer for visible-light integrated photonics. https://doi.org/10.1038/s41467-025-61970-0

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Two-step high-accuracy microwave frequency measurement and time-frequency analysis based on optical frequency combs

Broadband microwave frequency measurement and time-frequency analysis are crucial for applications such as electronic warfare. However, when it comes to ultra wideband signal analysis, traditional electronic methods have high analysis accuracy, but intrinsic electronic bottlenecks limit their real-time analysis. Here, we propose and experimentally demonstrate a two-step microwave frequency measurement and time-frequency analysis method based on optical frequency combs. The system first performs coarse frequency localization over the 0-40 GHz range using stimulated-Brillouin-scattering-assisted frequency-to-time mapping (FTTM) and dual-comb channelized reception. The dual-comb is then reapplied for downconverting the signal under test, followed by digital signal processing to achieve high-accuracy unambiguous frequency extraction. Experimental results show that the system achieves mean single-tone frequency measurement errors of less than 10 kHz over 0-40 GHz. We further experimentally measure multi-tone, linearly frequency-modulated, and V-shaped frequency-modulated signals, demonstrating the proposed method's capability for analyzing complex signals.

physics.optics

A Two-Mirror Faceted Projection System for EUV Lithography

We propose an all-reflective two-mirror projection system for extreme ultraviolet (EUV) lithography operating at exposure wavelengths of $13.5$~nm (Mo/Si) and $11.2$~nm (Ru/Be), delivering a fourfold ($4\times$) demagnification of the periodic mask pattern at a numerical aperture approaching unity ($\mathrm{NA}_{\max} \approx 0.993$). In contrast to conventional EUV projection objectives that incorporate 6--10 aspheric mirrors with an overall optical throughput of less than $15\%$, the proposed design redirects each accepted discrete spatial diffraction order scattered by the mask onto the wafer via a dedicated pair of planar mirror facets. The number of reflections is strictly fixed at two for all accepted orders, retaining $50$--$60\%$ of the power leaving the mask in each accepted order. We derive a spatial geometry providing rigorous optical path length equalization across all diffraction orders, thereby removing order-dependent propagation phase shifts. Individually optimized 30-bilayer Bragg multilayer coatings are designed for each facet using the transfer matrix method combined with global evolutionary optimization algorithms. The architecture is generalized to a three-dimensional vector formulation with a two-dimensionally periodic mask. Utilizing inverse lithography technology, Fourier parameterization, and a differentiable electromagnetic modal waveguide solver, we solve the synthesis problem for binary absorber masks (La absorber on a Ru/Be/Sr multilayer mirror). We demonstrate simulated aerial images of sub-10-nm features on the wafer (isolated peaks with a full width at half maximum (FWHM) of approximately $5.4$~nm and line pairs with a critical dimension of $6$~nm) and find that the two peaks remain resolved for the tested wafer defocus values from $0$ to $5$~nm along the $z$-axis.

physics.optics

Antimony for broadband nanophotonics across the ultraviolet, visible and infrared

Semimetal elemental antimony (Sb) nanostructures show great potential for applications where nanophotonic properties play a key role, such as phase-change optical memories, non-linear optical elements, photothermal therapy agents, photodetectors and photocatalysts. However, designing advanced Sb-based photonic devices critically requires an accurate and reliable knowledge of the optical response of bulk and nanoscale Sb. Herein, we report for the first time a fully consistent and accurately measured dielectric function for Sb nanoscale films in a wide spectral range from the ultraviolet to the far infrared (4 - 0.04 eV, i.e. ~ 0.3 - 30 $\mu$m), surpassing previous reports that explored a limited spectral range. It is found that the Sb spectral response is driven exclusively by giant interband transitions in the visible up to mid infrared (4 - 0.4 eV, i.e. ~ 0.3 - 3 $\mu$m), and that their contribution dominates over that of free carriers down to 0.12 eV (i.e. ~ 10 $\mu$m). Such spectral response enables Sb nanostructures to display spectrally selective and tunable nanophotonic resonances. First, we showcase interband plasmonic resonances in the visible-to-near infrared for Sb nanogratings. Second, we report giant refractive index dielectric resonances in the mid infrared for nanostructured Sb/dielectric/metal resonant cavities. These findings open a pathway to optimized planar Sb nanoscale designs enabling a tailored light-matter interaction, which will be useful for integrated data, telecom, medical, optoelectronic and energy conversion devices operating in a broad spectral range.

physics.optics