SearcharxivSearch

arXiv · 1412.3086

Letter of Intent to Construct a nuPRISM Detector in the J-PARC Neutrino Beamline

Abstract

As long-baseline neutrino experiments enter the precision era, the difficulties associated with understanding neutrino interaction cross sections on atomic nuclei are expected to limit experimental sensitivities to oscillation parameters. In particular, the ability to relate experimental observables to neutrino energy in previous experiments has relied solely on theoretical models of neutrino-nucleus interactions, which currently suffer from very large theoretical uncertainties. By observing charged current $ν_μ$ interactions over a continuous range of off-axis angles from 1 to 4 degrees, the nuPRISM water Cherenkov detector can provide a direct measurement of the far detector lepton kinematics for any given set of oscillation parameters, which largely removes neutrino interaction modeling uncertainties from T2K oscillation measurements. This naturally provides a direct constraint on the relationship between lepton kinematics and neutrino energy. In addition, nuPRISM is a sensitive probe of sterile neutrino oscillations with multiple energy spectra, which provides unique constraints on possible background-related explanations of the MiniBooNE anomaly. Finally, high-precision measurements of neutrino cross sections on water are possible, including $ν_e$ measurements and the first ever measurements of neutral current interactions as a function of neutrino energy. The nuPRISM detector also benefits the proposed Hyper-Kamiokande project. A demonstration that neutrino interaction uncertainties can be controlled will be important to understanding the physics reach of Hyper-K. In addition, nuPRISM will provide an easily accessible prototype detector for many of the new hardware components currently under consideration for Hyper-K. The following document presents the configuration, physics impact, and preliminary cost estimates for a nuPRISM detector in the J-PARC neutrino beamline.

Explore related subjects

Keep this discovery

BibTeXRIS

S. Bhadra, A. Blondel, S. Bordoni, A. Bravar, C. Bronner, J. Caravaca-Rodriguez, M. Dziewiecki, T. Feusels, G. A. Fiorentini-Aguirre, M. Friend, L. Haegel, M. Hartz, R. Henderson, T. Ishida, M. Ishitsuka, C. K. Jung, A. C. Kaboth, H. Kakuno, H. Kamano, A. Konaka, Y. Kudenko, M. Kuze, T. Lindner, K. Mahn, J. F. Martin, J. Marzec, K. S. McFarland, S. Nakayama, T. Nakaya, S. Nakamura, Y. Nishimura, A. Rychter, F. Sanchez, T. Sato, M. Scott, T. Sekiguchi, M. Shiozawa, T. Sumiyoshi, R. Tacik, H. K. Tanaka, H. A. Tanaka, S. Tobayama, M. Vagins, J. Vo, D. Wark, M. O. Wascko, M. J. Wilking, S. Yen, M. Yokoyama, M. Ziembicki. 2014-12-13. Letter of Intent to Construct a nuPRISM Detector in the J-PARC Neutrino Beamline. https://arxiv.org/abs/1412.3086

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det