SearcharxivSearch

arXiv · 1812.01078

Effect of Geometry on Sensitivity and Offset of AlGaN/GaN and InAlN/GaN Hall-effect Sensors

Abstract

The current- and voltage-scaled sensitivities and signal-to-noise ratios (SNR) (with respect to thermal noise) of various octagonal AlGaN/GaN and InAlN/GaN Hall-effect sensors were examined in this work. The effect of metal contact lengths on sensitivity and sensor offset was evaluated. Calculations that take into account the shape of the device show that devices with point-like contacts have the highest current-scaled sensitivity (68.9 V/A/T), while devices with contacts of equal length to their non-contact sides have the highest voltage-scaled sensitivity (86.9 mV/V/T). The sensitivities of the two other devices follow the predicted trends closely. All the devices have offsets less than 20 $\mu$T at low supply current operation (< 300 $\mu$A) and most remain below 35 $\mu$T at higher supply current (up to 1.2 mA). The consistent low offsets across the devices imply that the choice of Hall-effect sensor geometry should mainly depend on whether the device is current-biased or voltage-biased and the frequency at which it will operate. This work demonstrates that GaN Hall-effect sensor performance can be improved by adjusting the geometry of the Hall-effect plate specific to its function (e.g., power electronics, navigation, automotive applications).

Explore related subjects

Keep this discovery

BibTeXRIS

Hannah S. Alpert, Karen M. Dowling, Caitlin A. Chapin, Ananth Saran Yalamarthy, Savannah R. Benbrook, Helmut Köck, Udo Ausserlechner, Debbie G. Senesky. 2018-12-03. Effect of Geometry on Sensitivity and Offset of AlGaN/GaN and InAlN/GaN Hall-effect Sensors. https://doi.org/10.1109/jsen.2019.2895546

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det