arXiv · 2002.06216
Development of readout electronics a novel beam monitoring system for ion research facility accelerator
Abstract
This article presents the readout electronics of a novel beam monitoring system for ion research facility accelerator. The readout electronics are divided into Front-end Card (FEC) and Readout Control Unit (RCU). FEC uses Topmetal II minus to processes the energy of the hitting particles and convert it into a voltage signal. The main function of RCU is to digitize the analog output signal of FEC and format the raw data. On the other hand, the RCU also processes the control commands from the host and distributes the commands according to the mapping. The readout electronic has been characterized and calibrated in the laboratory, and have been installed with the detector. Implementation and testing of readout electronics have been discussed.
Explore related subjects
Keep this discovery
Honglin Zhang, Haibo Yang, Xianqin Li, Yuezhao Zhang, Xiangming Sun, Dong Wang, Ran Huang, Yao Wang, Wei Zhou, Chengxin Zhao. 2020-02-13. Development of readout electronics a novel beam monitoring system for ion research facility accelerator. https://arxiv.org/abs/2002.06216
Cite the original work for its findings. Save a collection to share your selection of sources.