Ageing studies of Multi-Strip Multi-Gap Resistive Plate Counters based on low resistivity glass electrodes in high irradiation dose
Abstract
Detailed tests and analysis of ageing effects of high irradiation dose on Multi-Strip Multi-Gap Resistive Plate Counters based on low resistivity glass electrodes were performed. MSMGRPC efficiency and cluster size before irradiation are measured and compared with their values after irradiation in a high irradiation dose accessed at a multi-purpose irradiation facility of IFIN-HH based on $^{60}$Co source. The composition and properties of the deposited layers on the glass electrodes, studied based on a multitude of analysis methods, i.e. SEM, XPS, foil-ERDA, RBS, AFM and THz-TDS, are presented.
Explore related subjects
Keep this discovery
D. Bartos, C. Burducea, I. Burducea, G. Caragheorgheopol, F. Constantin, L. Craciun, D. Dorobantu, M. Ghena, D. Iancu, A. Marcu, G. Mateescu, P. Mereuta, V. Moise, C. Negrila, D. Negut, M. Petris, M. Petrovici, L. Radulescu, V. Aprodu, L. Prodan, A. radu, G. Stoian. 2021-05-24. Ageing studies of Multi-Strip Multi-Gap Resistive Plate Counters based on low resistivity glass electrodes in high irradiation dose. https://doi.org/10.1016/j.nima.2021.166122