SearcharxivSearch

arXiv · 2111.11323

Can the electric field in radiation-damaged silicon pad diodes be determined by admittance and current measurements?

Abstract

A method is proposed for determining the electric field in highly-irradiated silicon pad diodes using admittance-frequency (Y-f ), and current measurements (I). The method is applied to Y-f and I data from square n+p diodes of 25mm2 area irradiated by 24 GeV/c protons to four 1MeV neutron equivalent fluences between 3E15 cm^2 and 13E15 cm^2. The measurement conditions were: Reverse voltages between 1V and 1000V, frequencies between 100Hz and 2MHz and temperatures of -20{\deg}C and -30{\deg}C. The position dependence of the electric field is parameterised by a linear dependence at the two sides of the diode, and a constant in the centre. The parameters as a function of voltage, temperature and irradiation fluence are determined by fits of the model to the data. For voltages below about 300V all data are well described by the model, and the results for the electric field agrees with expectations: Depleted high-field regions towards the two faces and a constant low electric field in the centre, with values which agrees with the field in an ohmic resistor with approximately the intrinsic resistivity of silicon. For conditions at which the low field region disappears and the diode is fully depleted, the method fails. This happens around 300V for the lowest irradiation fluence at -30{\deg}C, and at higher voltages for higher fluences and lower temperatures. In the conclusions the successes and problems of the method are discussed.

Explore related subjects

Keep this discovery

BibTeXRIS

R. Klanner, J. Schwandt. 2021-11-22. Can the electric field in radiation-damaged silicon pad diodes be determined by admittance and current measurements?. https://doi.org/10.1016/j.nima.2022.166360

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det