arXiv · 2204.08739
Characterization of timing and spacial resolution of novel TI-LGAD structures before and after irradiation
Abstract
The characterization of spacial and timing resolution of the novel Trench Isolated LGAD (TI-LGAD) technology is presented. This technology has been developed at FBK with the goal of achieving 4D pixels, where an accurate position resolution is combined in a single device with the precise timing determination for Minimum Ionizing Particles (MIPs). In the TI-LGAD technology, the pixelated LGAD pads are separated by physical trenches etched in the silicon. This technology can reduce the interpixel dead area, mitigating the fill factor problem. The TI-RD50 production studied in this work is the first one of pixelated TI-LGADs. The characterization was performed using a scanning TCT setup with an infrared laser and a $^{90}$Sr source setup.
Explore related subjects
Keep this discovery
Matias Senger, Ashish Bisht, Giacomo Borghi, Maurizio Boscardin, Matteo Centis Vignali, Federico Ficorella, Omar Hammad Ali, Ben Kilminster, Anna Macchiolo, Giovanni Paternoster. 2022-04-19. Characterization of timing and spacial resolution of novel TI-LGAD structures before and after irradiation. https://doi.org/10.1016/j.nima.2022.167030
Cite the original work for its findings. Save a collection to share your selection of sources.