SiPM and PMT Driving, Signals Count and Peak Detection Circuits, suitable for Particle Detection

Abstract

The signals received from the optical receivers like as SiPM and PMT due to the collision of energetic particles with the scintillators attached to these optical receivers, are weak and fast. To measure the number of signals as well as their peak height with electronic circuits, it is necessary to optimize the signals. An example of SiPM driver circuit, signal counting and peak measurement is presented in this text. Also, the electronic circuits necessary to optimize the signals, including amplification, elimination of background noise, conversion of signal to digital and increase of signal duration are presented in this text. At the end, two examples of test results are provided to confirm the correct operation of the circuits. Such a system has several advantages. This set has a small volume and is easily portable. Its operating voltage is 12 volts and with a current of about 0.3 amps, as a result of which it is possible to use this set in any test easily. In addition, the cost of building such a system is much less than providing similar ready-made systems. Therefore, it seems that the use of all or part of these circuits can be useful for researchers. This text, while providing a special method for optimizing the signals, provides the reader with a coherent and complete method of constructing and testing circuits, and if the reader is familiar with the basics of electronics and detectors, he or she can reconstruct the circuits without any problems. Therefore, parts of this text may have an educational and review form. It seems that without these sections, the right to read will not be fulfilled.

Explore related subjects

Keep this discovery

BibTeXRIS

Gholamreza Fardipour Raki, Maryam Ghahremani Gol, Mohammad Sahraei, Mohsen Khakzad. 2022-05-10. SiPM and PMT Driving, Signals Count and Peak Detection Circuits, suitable for Particle Detection. https://doi.org/10.1088/1748-0221%2F17%2F09%2Ft09011

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det