Characterization of a Superconducting Microstrip Single-Photon Detector Shunted with an External Resistor

Abstract

A superconducting microstrip single-photon detector (SMSPD) generally requires a shunt resistor to avoid latching, caused by its high current-carrying capacity and low kinetic inductance. Here, the effect of the shunt resistor on the behaviors of microbridge SMSPDs was investigated. We analyzed the change in equivalent switching current at different shunt resistances in two ways and determined the operating current range using intrinsic dark count rate (iDCR) curves. We observed that the reduction in shunt resistance can increase the operating current range, which helps to improve the internal detection efficiency (IDE) and reduce the iDCR. However, the reduction in the shunt resistance can reduce the pulse amplitude and increase the pulse decay time, which can degrade the timing jitter and count rate performance of the SMSPD. The trends of the experimental results can be qualitatively reproduced using a circuit model for an SMSPD with a shunt resistor, which provides useful information for the selection of shunt resistors. Furthermore, we report the improved detection performance of a helium-ion-irradiated SMSPD shunted with a small resistance of 5.2 {\Omega}. We observed a weak IDE saturation with a bias current at a wavelength up to 2000 nm and a nonlinear relation between detection current and photon energy.

Explore related subjects

Keep this discovery

BibTeXRIS

Yu-Ze Wang, Wei-Jun Zhang, Guang-Zhao Xu, Jia-Min Xiong, Dong-Hui Fan, Zhi-Gang Chen, Xing-Yu Zhang, Zhen Wang, Li-Xing You. 2023-04-18. Characterization of a Superconducting Microstrip Single-Photon Detector Shunted with an External Resistor. https://doi.org/10.1088/1361-6668/acce74

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det