SearcharxivSearch

arXiv · 2312.07957

Scintillation characteristics of an undoped CsI crystal at low-temperature for dark matter search

Abstract

The scintillation characteristics of 1 g undoped CsI crystal were studied by directly coupling two silicon photomultipliers(SiPMs) over a temperature range from room temperature to 86 K. The scintillation decay time and light output were measured using x-ray and gamma-ray peaks from a 109Cd radioactive source. An increase in decay time was observed as the temperature decreased from room temperature to 86 K, ranging from 76 ns to 605 ns. The light output also increased, reaching 26.2 +/- 1.3 photoelectrons per keV electron-equivalent at 86 K. Leveraging the significantly enhanced scintillation light output of the undoped CsI crystal at low temperatures, coupling it with SiPMs results in a promising detector for rare event searches. Both cesium and iodine have an odd number of protons, making them suitable targets for probing dark matter-proton spin-dependent interactions. This study evaluates the sensitivity of the proposed detector to such interactions, incorporating the Migdal effect and assuming 200 kg of undoped CsI crystals for dark matter searches. The results indicate that undoped CsI coupled with SiPM can achieve world-competitive sensitivity for low-mass dark matter detection, particularly in the context of dark matter-proton spin-dependent interactions.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

W. K. Kim, H. Y. Lee, K. W. Kim, Y. J. Ko, J. A. Jeon, H. J. Kim, H. S. Lee. 2023-12-13. Scintillation characteristics of an undoped CsI crystal at low-temperature for dark matter search. https://doi.org/10.1016/j.astropartphys.2025.103150

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det