arXiv · 2405.12454
A Compact Readout Electronics Based on Current Amplifier for Micromegas Detector in Muon Imaging
Abstract
Muon imaging technology is an innovative imaging technique that can be applied in volcano imaging, heavy nuclear material detection, and archaeological research. The Micromegas detector is a promising choice for muon imaging due to its high spatial resolution and large area. However, the large number of readout channels poses a challenge for electronics. In this paper, a compact front-end electronics (FEE) for reading Micromegas detectors is presented. The electronics use the commercial current-to-digital readout chip, ADAS1128, which integrates 128 current amplifiers for multi-channel charge measurement. After verifying the basic performance of the electronics, the energy resolution was obtained with a radioactive source. Furthermore, a muon imaging system prototype was set up and its spatial resolution was evaluated in a test with cosmic ray muons. The system prototype can reconstruct the boundaries of sufficiently massive objects with a size of 2 cm in a scattering imaging test.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Ting Wang, Yu Wang, Zhihang Yao, Yulin Liu, Changqing Feng, Zhiyong Zhang, Shubin Liu. 2024-05-21. A Compact Readout Electronics Based on Current Amplifier for Micromegas Detector in Muon Imaging. https://arxiv.org/abs/2405.12454
Cite the original work for its findings. Save a collection to share your selection of sources.