Silicon photomultipliers (SiPMs) are being considered as potential replacements for conventional photomultiplier tubes (PMTs). However, a significant disadvantage of SiPMs is crosstalk (CT), wherein photons propagate through other pixels, resulting in secondary avalanches. CT can be categorized into internal crosstalk and external crosstalk based on whether the secondary avalanche occurs within the same SiPM or a different one. Numerous methods exist for quantitatively estimating the percentage of internal crosstalk (iCT). However, external crosstalk (eCT) has not been extensively studied. This article presents a novel measurement method for the probability of emitting an external crosstalk photon during a single pixel avalanche, using a setup involving two identical SiPMs facing each other, and without the need for complex optical designs. The entire apparatus is enclosed within a stainless steel chamber, functioning as a light-tight enclosure, and maintained at liquid nitrogen temperature. The experimental setup incorporates two Sensl J-60035 SiPM chips along with two 0.5-inch Hamamatsu Photonics (HPK) VUV4 S13370-6050CN SiPM arrays. The findings show a linear relationship between the probability of emitting an external crosstalk photon and the SiPM overvoltage for both SiPM samples. Surprisingly, this novel measurement method also rovides measurements of the SiPM photon detection efficiency (PDE) for eCT photons at low temperature.

Explore related subjects

Keep this discovery

BibTeXRIS

Guanda Li, Lei Wang, Xilei Sun, Fang Liu, Cong Guo, Kangkang Zhao, Lei Tian, Zeyuan Yu, Zhilong Hou, Chi Li, Yu Lei, Bin Wang, Rongbin Zhou. 2024-06-04. A novel measurement method for SiPM external crosstalk probability at low temperature. https://arxiv.org/abs/2406.02249

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det