SearcharxivSearch

arXiv · 2406.09764

MKIDGen3: Energy-Resolving, Single-Photon-Counting MKID Readout on an RFSoC

Abstract

Building large, cryogenic MKID arrays requires processing highly-multiplexed, wideband readout signals in real time; a task that has previously required large, heavy, and power-intensive custom electronics. In this work, we present the third-generation UVOIR MKID readout system (Gen3) which is capable of reading out twice as many detectors with a fifth the weight and power and an order of magnitude less volume and cost-per-pixel as compared to the previous system. Gen3 leverages the Xilinx RFSoC4x2 platform to read out 2048, 1 MHz MKID channels per board. The system takes a modern approach to FPGA design using Vitis High-Level Synthesis (HLS) to specify signal processing blocks in C/C++, Vivado ML Intelligent Design Runs (IDR) to inform implementation stragety and close timing, and Python Productivity for ZYNQ (PYNQ) to simplify interacting with and programming the FPGA using Python. This design suite and tool flow allows general users to contribute to and maintain the design and positions Gen3 to rapidly migrate to future platforms as they become available. In this work, we describe the system requirements, design, and implementation. We also provide performance characterization details and show that the system achieves detector-limited resolving power in the case of few readout tones and minimal degradation with all 2048 tones. Planned upgrades and future work are also discussed. The Gen3 MKID readout system is fully open-source and is expected to facilitate future array scaling to megapixel-sized formats and increase the feasibility of deploying UVOIR MKIDs in space.

Explore related subjects

Keep this discovery

BibTeXRIS

Jennifer Pearl Smith, John I. Bailey, III., Aled Cuda, Nicholas Zobrist, Benjamin A. Mazin. 2024-06-14. MKIDGen3: Energy-Resolving, Single-Photon-Counting MKID Readout on an RFSoC. https://arxiv.org/abs/2406.09764

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det