SearcharxivSearch

arXiv · 2408.01646

Feasibility of Liquid-phase Xenon Proportional Scintillation for Low-energy Physics

Abstract

Dual phase xenon time projection chambers (TPCs) detect both the scintillation photons and ionization electrons created by energy depositions within the liquid xenon (LXe) volume. The electrons are extracted from the interaction site through a gas gap, where they meet a high electric field where proportional scintillation occurs. This converts the electron signal into a light signal, and yields a high electron detection efficiency with a gain of tens of photoelectrons (PE) per electron. This technique of detecting both scintillation and ionization gives dual phase xenon TPCs the capability to distinguish between electronic and nuclear recoils, which is a key part of how these detectors are able to reach world-leading limits on Weakly Interacting Massive Particle (WIMP) dark matter. However, not all electrons can be extracted through the liquid-gas interface, and a constant millimeter-scale gas gap needs to be maintained, which may be a technological challenge if dual-phase xenon TPCs are to be scaled up for future dark matter searches. Furthermore, there is a background of single-electron peaks that follow a large ionization signal (S2) of unclear origin which may be due in part to the liquid-gas interface, and limits the sensitivity of these detectors towards low mass dark matter. In this paper, we demonstrate that a purely single-phase liquid xenon TPC which produces proportional scintillation directly in the liquid is still capable of discriminating between electronic and nuclear recoils, but that the background of single-electrons following an S2 is still likely unrelated to the liquid-gas interface.

Explore related subjects

Keep this discovery

BibTeXRIS

Jianyang Qi, Kaixuan Ni, Haiwen Xu, Yue Ma, Yuechen Liu. 2024-08-03. Feasibility of Liquid-phase Xenon Proportional Scintillation for Low-energy Physics. https://doi.org/10.1103/physrevd.111.012005

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det