SearcharxivSearch

arXiv · 2409.00504

Monte Carlo calculations of cryogenic photodetector readout of scintillating GaAs for dark matter detection

Abstract

The recent discovery that GaAs(Si,B) is a bright cryogenic scintillator with no apparent afterglow offers new opportunities for detecting rare, low-energy, electronic excitations from interacting dark matter. This paper presents Monte Carlo calculations of the scintillation photon detection efficiencies of optical cavities using three current cryogenic photodetector technologies. In order of photon detection efficiency these are: (1) Ge/TES: germanium absorbers that convert interacting photons to athermal phonons that are readout by transition edge sensors, (2) KID: kinetic induction detectors that respond to the breaking of cooper pairs by a change in resonance frequency, and (3) SNSPD: superconducting nanowire single photon detectors, where a photon briefly transitions a thin wire from superconducting to normal. The detection efficiencies depend strongly on the n-type GaAs absolute absorption coefficient KA, which is a part of the narrow beam absorption that has never been directly measured. However, the high cryogenic scintillation luminosity of GaAs(Si,B) sets an upper limit on KA of 0.03/cm. Using that value and properties published for Ge/TES, KID, and SNSPD photodetectors, this work calculates that those photodetectors attached to opposing faces of a 1 cm3 cubic GaAs(Si,B) crystal in an optical cavity with gold mirrors would have scintillation photon detection efficiencies of 35%, 25%, and 8%, respectively. Larger values would be expected for lower values of KA.

Explore related subjects

Keep this discovery

BibTeXRIS

Stephen E. Derenzo. 2024-08-31. Monte Carlo calculations of cryogenic photodetector readout of scintillating GaAs for dark matter detection. https://arxiv.org/abs/2409.00504

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det