SearcharxivSearch

arXiv · 2508.06498

High-density and scalable graphene Hall sensor arrays through monolithic CMOS integration

Abstract

Electronic devices made from two-dimensional materials (2DMs) significantly outperform their silicon counterparts; however, silicon CMOS technology remains commercially predominant as it offers the capability to operate dense arrays of devices in a scalable fashion. In particular, graphene Hall sensors (GHSs) offer great improvements in magnetic field sensitivity and resolution compared to silicon Hall-effect sensors, making them extremely appealing for magnetic field imaging and biosensing. At present, GHS arrays have limited scalability compared to silicon CMOS since they require planar routing for biasing and multiplexing. In this work, we explore strategies to realize high-density graphene Hall sensor arrays by vertically connecting GHSs with silicon CMOS biasing and multiplexing circuitry, allowing the routing and circuitry to scale with the array. We investigate the importance of design choices in the chip layout and post-fabrication process in maximizing the reliability of graphene transfer onto mm-scale CMOS dies. Our experimental results validate the success of the integration process by showing for the first time that GHSs can be monolithically integrated with CMOS with high yield to form sensor arrays. We expect that these results will lead to further improvements in magnetic sensing technology and broader advancements in large-scale heterogeneous 2DM-CMOS systems.

Explore related subjects

Keep this discovery

BibTeXRIS

Vasant Iyer, Nishal Shah, A. T. Charlie Johnson, David A. Issadore, Firooz Aflatouni. 2025-07-24. High-density and scalable graphene Hall sensor arrays through monolithic CMOS integration. https://doi.org/10.1002/aelm.202500776

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det