SearcharxivSearch

arXiv · 2605.07406

Design and Characterization of Racetrack 3D-Trench Silicon Sensor Based on 8-Inch Process with Excellent Time Resolution

Abstract

In the extreme environments of high-luminosity colliders, traditional planar silicon sensors suffer severe radiation-induced performance degradation and fail to satisfy the stringent demands of high-precision tracking and high-speed timing in particle physics. 3D silicon sensors enhance radiation hardness by shortening charge collection distance, yet conventional designs with columnar or square-cell trench electrodes exhibit non-uniform electric fields, including saddle points and low-field regions, which degrade charge collection efficiency and timing resolution. This work presents a novel racetrack 3D-trench silicon sensor with continuous racetrack electrodes surrounding a long central collection electrode, aiming to eliminate electric field inhomogeneities. For the first time, a 23 $\mu $m shallow-etched device was fabricated on an 8-inch platform, which provides a promising basis for its subsequent mass production and engineering applications. The device performance was systematically evaluated through theoretical analysis, 3D TCAD simulations, and characterization using semiconductor parameter analyzers and transient current technique (TCT) measurements. The sensor achieves leakage current below 0.2 nA, breakdown voltage above 110 V, full depletion voltage as low as a few volts, capacitance as low as 650 fF, collected charge of 4 fC, time response of about 640 ps, and time resolution of 50 ps. This large-scale manufacturable, shallow-etched racetrack 3D-trench silicon sensor provides a competitive device solution for portable radiation detection and next-generation 4D tracking under high-radiation and high-event-rate conditions.

Explore related subjects

Keep this discovery

BibTeXRIS

Huimin Ji, Manwen Liu, Kuo Ma, Chuan Liao, Yanwen Liu, Zheng Li, Zhihua Li, Jun Luo. 2026-05-08. Design and Characterization of Racetrack 3D-Trench Silicon Sensor Based on 8-Inch Process with Excellent Time Resolution. https://arxiv.org/abs/2605.07406

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det