Radiation effects on surface and bulk properties of ATLAS18 silicon sensors under low- and high-dose gamma irradiation and annealing

Abstract

Silicon strip detectors for the ATLAS Inner Tracker (ITk) at the HL-LHC must withstand harsh radiation conditions, including fluences of up to 1.6E15 1 MeV n$_{eq}$/cm$^{2}$ and total ionizing doses (TID) of up to 66 Mrad. These requirements are met using radiation-hard n+-in-p technology implemented in the ATLAS18 silicon strip sensors currently under production. This work presents a combined study of gamma-irradiation effects in ATLAS18 silicon sensors, including both segmented miniature strip sensors (minis) and unsegmented MD8 diodes fabricated on ATLAS18 production wafers. The samples were irradiated with a $^{60}$Co gamma source to multiple low TIDs between 0.5 and 100 krad, corresponding to the dose range relevant for the early operational phase of the ITk tracker. Additional measurements extending up to a few Mrad were performed to investigate the saturation of surface related damage effects. Post-irradiation characterization included measurements of total, bulk, and surface leakage currents, as well as capacitance-voltage measurements used to extract the full depletion voltage. The thermal stability of radiation-induced defects was studied using isochronal annealing between 80{\deg}C and 300{\deg}C and isothermal annealing at 60{\deg}C and 160{\deg}C. In addition, complementary studies of MD8 diodes irradiated to ultra-high doses of several hundred Mrad, well beyond the ATLAS ITk requirements, are included to investigate possible bulk-related effects induced by pure gamma irradiation and their annealing behavior. The combined analysis of low- and ultra-high-dose irradiation provides a comprehensive picture of surface- and bulk-related gamma-induced effects in ATLAS18 silicon sensors and their thermal evolution.

Explore related subjects

Keep this discovery

BibTeXRIS

Marcela Mikestikova, Vitaliy Fadeyev, Pavla Federicova, Petr Gallus, Jana Kozakova, Jiri Kroll, Magdalena Kutova, Jiri Kvasnicka, Igor Mandic, Pavel Tuma, Miguel Ullan, Yoshinobu Unno, Iveta Zatocilova. 2026-07-15. Radiation effects on surface and bulk properties of ATLAS18 silicon sensors under low- and high-dose gamma irradiation and annealing. https://doi.org/10.1016/j.nima.2026.171812

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det