arXiv · 2609.12430
An integrated readout system for parallel-plate avalanche counter and multi-wire drift chamber at HIAF-HIRIBL
Abstract
A newly developed, highly-integrated multi-channel front-end readout system -- FEAM-256 -- is presented for use with position-sensitive gaseous detectors, including parallel-plate avalanche counters (PPACs) and multi-wire drift chambers (MWDCs). The system's position resolution was characterized using both an $α$ source and cosmic-ray muons. Intrinsic position resolutions of 320 $μ$m for the PPAC, and 424 $μ$m for the MWDC were achieved. Designed specifically for integration into the data-acquisition infrastructure at the High-Rigidity radioactive Ion Beam Line (HIRIBL) of China's High Intensity heavy-ion Accelerator Facility (HIAF), FEAM-256 enables seamless incorporation of PPAC and MWDC detectors into the HIRIBL experimental setup.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
E. Q. Liu, T. S. Huang, Z. X. Ma, Z. P. Sun, L. Li, H. J. Ong, H. Wang, S. Terashima, L. M Duan, H. R Yang, Y. Qian, F. S. Shi, Y. N. Song, B. H. Sun, X. D. Xu, J. W. Yan, Z. C. Zhang. 2026-09-11. An integrated readout system for parallel-plate avalanche counter and multi-wire drift chamber at HIAF-HIRIBL. https://arxiv.org/abs/2609.12430
Cite the original work for its findings. Save a collection to share your selection of sources.