Investigating Optical Coupling Material Candidates in NaI(Tl) Detectors for the SABRE-North Dark Matter Experiment

Abstract

Direct dark matter detection with NaI(Tl) scintillators requires ultra-low-background materials. Silicone optical pads can couple NaI(Tl) crystals to photomultiplier tubes (PMTs) if they provide adequate optical transmission and radiopurity. We characterize four candidate materials for the SABRE-North experiment: commercial EJ-560, used as a reference, and three materials produced at the University of Salento (SYLGARD 184, EGel 3002 A/B, and a hybrid formulation) using different catalyst ratios and curing conditions, yielding ten samples in total. Optical transmittance was measured from 310 to 850 nm by UV/Vis/NIR spectrophotometry. Radiopurity was assessed at the STELLA facility at LNGS using high-purity germanium (HPGe) $γ$-ray spectrometry and, for EJ-560, high-resolution ICP-MS. At the 410 nm NaI(Tl) emission peak, EJ-560 shows an absorbance coefficient of $0.064\pm0.017$ mm$^{-1}$. The best locally produced samples reach $0.097\pm0.015$ and $0.093\pm0.014$ mm$^{-1}$ for SYLGARD 184 with a 10:2 base-to-catalyst ratio cured at room temperature and at $40^\circ$C, respectively, $0.125\pm0.015$ mm$^{-1}$ for EGel 3002 with a 2B:A ratio cured at $40^\circ$C, and $0.106\pm0.014$ mm$^{-1}$ for the hybrid 10:1 EGel A:CataSYL formulation cured at room temperature. EJ-560 exhibits detectable $^{232}$Th-chain activity at about 1.8 mBq/kg and the highest $^{40}$K activity, $(120\pm20)$ mBq/kg. The locally produced materials show no detectable Th-chain contamination but exhibit $^{226}$Ra activities of about 2.3 mBq/kg and lower $^{40}$K levels. No single material is optimal across all criteria. Additional ICP-MS screening, HPGe measurements of cured pads, and direct NaI(Tl)-PMT light-yield tests are required for a conclusive SABRE-North material selection.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Chemseddine Ananna, Gabriella Cataldi, Davide D'Angelo, Giulia D'Imperio, Maria Luisa De Giorgi, Giuseppe Di Carlo, Attilio Di Giacinto, Marcella Diemoz, Aldo Ianni, Sana Gul Khattak, Edoardo Martinenghi, Alessandro Miccoli, Marcin Misiaszek, Daniele Montanino, Valerio Pettinacci, Lidio Pietrofaccia, Shahram Rahatlou, Krzysztof Szczepaniec, Claudia Tomei, Valerio Toso, Chiara Vignoli, Samina Zuhra, Francesco Ferella, Stefano Nisi. 2026-10-05. Investigating Optical Coupling Material Candidates in NaI(Tl) Detectors for the SABRE-North Dark Matter Experiment. https://arxiv.org/abs/2610.06029

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

GEANT4-Based Comparative Study of Detector Response in Reduced and Fully Instrumented Silicon-Tungsten Sampling Calorimeter

{A GEANT4-based simulation study of a silicon--tungsten (Si--W) sampling calorimeter is presented to investigate electromagnetic shower development and detector response in the energy range of 1--120 GeV. Two detector configurations are considered: a reduced sequential-sampling prototype (Configuration-I), where a single silicon detector layer is placed downstream of progressively increasing tungsten absorber depths to sample the longitudinal shower evolution, and a fully instrumented sampling calorimeter (Configuration-II) consisting of twenty silicon layers interleaved with tungsten absorbers. The detector response is studied in terms of longitudinal shower development, shower maximum position, energy deposition, detector linearity, and calorimetric performance. Configuration-II provides simultaneous longitudinal sampling and allows event-by-event reconstruction of the deposited energy, yielding the expected linear response and energy resolution. Configuration-I reproduces the average longitudinal shower profiles and exhibits a strong linear correlation with the integrated shower response of Configuration-II. Although the absence of event-by-event multi-layer sampling prevents a direct determination of calorimetric energy resolution in Configuration-I, the observed correlation between two configurations is used to relate the response of the reduced prototype to that of the fully instrumented calorimeter and to estimate the corresponding calorimetric performance. The results demonstrate that the reduced prototype successfully reproduces the main characteristics of electromagnetic shower development observed in the fully instrumented detector, establishing its usefulness for detector characterization and test-beam studies when the construction of a complete prototype is limited by available resources.

physics.ins-det↗

Omnidirectional Radiation Detector with Perpendicular Dual Silicon Photomultiplier Readout - Directional Sensitivity and Machine Learning Source Positioning

Directional information of incident gamma rays in radiation detection is essential to many applications, from medical imaging to mapping radioactive contamination after nuclear accidents, characterization of nuclear waste during decommissioning, and nuclear security. In this work, we present a radiation detector capable of detecting gamma-ray photons in 4$π$, utilizing Gadolinium Aluminum Gallium Garnet (GAGG) scintillating crystals and silicon photomultipliers (SiPMs). The GAGG crystals are assembled in a cubical 4$\times$4$\times$4 matrix, and their light output is read out by SiPMs from two neighboring sides. The size of each crystal is 3$\times$3$\times$3 mm$^3$, while the matrix pitch is 3.2 mm, matching the size and the pitch of the 4$\times$4 SiPMs for one-to-one coupling. The layers perpendicular to the SiPMs are separated by optical reflectors, providing efficient light collection while lowering the probability of inter-crystal leakage. The design of the radiation detector offers high detection efficiency and full-view imaging of gamma-ray sources through Compton scattering. Monte Carlo simulations were performed in Geant4 to evaluate the detection efficiency of the proposed design due to its geometrical non-uniformity. Machine learning models developed with the XGBoost algorithm were trained and tested on the simulated data to assess the capability of the detector to localize point sources of 511, 662, and 1275 keV energies. We find that the proposed design does not influence the collection efficiency of the high-energy gamma-ray photons and offers sensitivity to the direction of the incoming gamma rays. The trained models are capable of determining the source-to-detector distance of the Na-22 and Cs-137 point sources from measurements, thus providing initial conditions for faster image reconstruction.

physics.ins-det↗

Projection of purification performance for the RELICS experiment

The RELICS (REactor neutrino LIquid xenon Coherent elastic Scattering) experiment employs a dual-phase liquid xenon time projection chamber to search for Coherent Elastic Neutrino-Nucleus Scattering (CE$ν$NS) induced by reactor neutrinos. To detect these sub-keV nuclear recoils and minimize signal attenuation, it is critical to maintain a sufficiently low impurity concentration in the detector. This work presents a comprehensive purity evolution model developed to describe impurity migration inside the detector. Utilizing measured material outgassing rates as input parameters, the model incorporates non-uniform transport mechanisms of the impurities, including circulation, vaporization, and condensation. The model is validated using data from a dedicated prototype detector. Based on this validated model, projections for the purification performance of the upcoming RELICS-10 and RELICS-50 detectors are provided.

physics.ins-det↗