Searcharxiv⌕ Search

arXiv · 2610.23810

Experimental Demonstration of a Balanced Travelling Wave Parametric Amplifier

Abstract

Superconducting travelling-wave parametric amplifiers (TWPAs) provide broadband gain, low added noise, and high dynamic range, making them attractive for applications requiring wide instantaneous bandwidth. This is crucial for amplifying multiplexed narrow band signals spread over a wide frequency range, such as qubit resonator arrays, or amplifying inherently wide band signals, such as in spectrometers or radiometers. In many cases, however, the useful bandwidth of a TWPA is limited by the production of the idler tone at an image frequency. For three-wave-mixing (3WM) TWPAs, for example, an input signal at $f_s$ is indistinguishable from one at $f_p - f_s$, which can produce spectral ambiguity when the input spectrum is broadband or not known in advance. We experimentally demonstrate a balanced architecture that doubles the instantaneous image-rejected bandwidth available to a 3WM TWPA by spatially separating the amplified signal from the output pump and generated idler, which resolves the sideband degeneracy. The architecture consists of two amplifiers connected between a pair of 180$^{\circ}$ hybrid couplers, with the signal and pump injected and output through the sum and difference ports, respectively. Using two kinetic-inductance TWPAs, we demonstrate approximately 20 dB of signal gain across nearly an octave of bandwidth, together with pump rejection below --20 dB and an average image rejection of approximately --15 dB over the operating band. These results establish balanced TWPAs as a practical approach to broadband parametric amplification, enabling improved contamination free bandwidth and eliminating the need for complex filtering.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Nikita Klimovich, Peter K. Day, Henry G. Leduc, Boon-Kok Tan. 2026-10-16. Experimental Demonstration of a Balanced Travelling Wave Parametric Amplifier. https://arxiv.org/abs/2610.23810

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

First measurement of flux of the neutron background induced by accelerated neutrinos at the J-PARC facility

This article reports the measurement of the neutron background flux accidentally induced by the neutrino beam at the J-PARC facility in Japan. In particular, neutrino-nucleus neutral-current quasi-elastic (NCQE) scattering events, $ν~(\barν)+\rm{N}\toν~(\barν)+\rm{N'}$, can be obscured by a massive background of neutron-nucleus scattering events. The neutrons are produced within the materials (such as sand and concrete) located between the beam dump and the experimental area where the detectors are placed. We measured the accidental neutron events at the J-PARC neutrino facility using BGO and liquid scintillation detectors, with a plastic scintillation detector serving as an active veto counter. Based on a neutrino-mode data set of $2.972 \times 10^{20}$ POT, we observed 88 neutron-induced recoil proton events within an electron-equivalent recoil energy range of 0.98-11.60 $\rm MeV_{ee}$, selected via pulse-shape discrimination in the liquid scintillation detector. Accounting for the detection efficiency and resolution, and through comparison with simulations, the neutron flux was determined to be$[1.45^{+0.22}_{-0.24}~\rm{(stat.)} \pm 0.55~\rm{(sys.)}] \times 10^{-7}~\rm{cm}^{-2} \rm{s}^{-1}\rm{POT}^{-1}$,assuming an exponential neutron energy spectrum. This result will contribute to the evaluation of neutron backgrounds for neutrino experiments at the J-PARC facility.

physics.ins-det↗

A New High-Intensity Source for Ultracold Neutrons

The TRIUMF UltraCold Advanced Neutron (TUCAN) collaboration has completed a new superthermal source for ultracold neutrons (UCNs) at TRIUMF. Neutrons produced in a spallation target are moderated in heavy water and liquid deuterium, and are converted to ultracold neutrons by inelastic scattering inside superfluid $^4$He at around 1.1 K. During commissioning of the completed moderation and conversion system, including the liquid-deuterium moderator, up to $1.47(2)\times 10^7$ UCNs were detected outside the source in the experimental area following a 60 s accumulation period. At the same location, continuous operation produced detector rates of up to $6.75(3)\times 10^7$ UCN/s, and a density of 165.6(1) UCN/cm$^3$ was achieved in a 25.4 L external vessel. These measurements demonstrate high-intensity operation of a spallation-driven He-II UCN source, including extraction and transport to an external experimental area.

physics.ins-det↗

Improved aluminum film transport properties and enhanced TES response in athermal phonon detectors: implications for quasiparticle dynamics

Our detectors for Dark Matter and Coherent Elastic Neutrino--Nucleus Scattering (CE$ν$NS) use photolithographically patterned superconducting athermal phonon sensors that are coupled to kg-scale absorbers of different materials (germanium, silicon, sapphire). Following a particle interaction, athermal phonons from the bulk absorber break Cooper pairs in a superconducting aluminum film that surrounds a tungsten Transition Edge Sensor (TES) in equilibrium through electrothermal feedback. This sensor design is called Quasiparticle-trap-assisted Electro-thermal-feedback Transition-edge-sensor (QET). The QET aluminum film that absorbs the athermal phonons is patterned into fins with lengths limited by the quasiparticle diffusion length in aluminum. Improving the quasiparticle diffusion length in the superconducting aluminum is an area of vigorous research to improve phonon collection efficiency and increase the signal strength for lower-threshold searches. We report significantly improved aluminum films that show systematically larger grain sizes and residual-resistivity ratio (RRR) compared to detectors we have fabricated in the past. The improved RRR and grain sizes were expected to improve the collected signal for a given energy. We report higher signal strength achieved in a detector in comparison to another detector in which all other fabrication parameters were kept identical except for the aluminum film deposition.

physics.ins-det↗