Searcharxiv⌕ Search

arXiv · 2611.26698

The Simons Observatory: A Novel Design for Heat Strap at Sub-Kelvin Temperatures

Abstract

We present a novel process for the fabrication of copper heat straps and a measurement of their thermal performance at sub-Kelvin temperatures. The conductance of the heat straps is consistent with the bulk conductivity of annealed copper over the range 60 mK to 1 K. We find no evidence for deviation from a linear dependence of conductivity with temperature over the explored range, indicating that the contact resistance at the strap ends is sub-dominant. Heat straps developed and validated through the described process have been deployed in both the Large Aperture Telescope Receiver and a Small Aperture Telescope of the Simons Observatory and have met thermal requirements.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

John Orlowski-Scherer, Oorie Desai, Daniel Lee, Nicholas Galitzki, Alex Manduca, Mark Devlin, Dominic Horne, Henry Nachman, Yuhan Wang, Edward J. Wollack. 2026-11-19. The Simons Observatory: A Novel Design for Heat Strap at Sub-Kelvin Temperatures. https://searcharxiv.com/abs/2611.26698

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Searcharxiv by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related papers

Experimental and Monte Carlo Simulation Studies to Characterize a Low-Pressure Gas-Based Positive-Ion Detector with a Nanometer-Equivalent Sensitive Volume

Compact low-pressure gas-based positive-ion detectors offer a promising approach to measuring particle track structure at the nanometer scale. These detectors use electric fields to collect and multiply positive ions produced by the incident radiation in mm-sized holes in dielectric materials, achieving a nm-equivalent spatial resolution of the localization of ionization events when scaled to liquid water at unit density. In this work, a detector prototype featuring a 1.5 mm-diameter hole in a dielectric plate was experimentally characterized. Ion collection and multiplication were achieved by applying a negative high potential to the glass cathode 0.5~mm below the hole, assisted by a low drift field above the plate. A grounded readout electrode with a 0.8 mm hole covers the hole to prevent interactions of collected ions with the hole walls. The experimental setup was further modeled with Geant4-DNA and Garfield++ for deeper insight. By combining the measurements with the Monte Carlo simulations, a per-ion signal formation probability in the low single-digit percentage range was determined. Further, the signal formation mechanism, commonly attributed to ion-impact ionization within the hole, was critically examined. Ion-induced secondary electron emission from surfaces was considered a possible contributor to, or the primary mechanism of, signal formation that has not been addressed in detail in previous studies of this detector concept. Despite the extensive measurements and simulations, the available evidence did not reveal which physical processes governed signal formation or whether either mechanism dominates. We discuss key limitations in the current understanding of this detector class and propose future targeted measurements and simulations to clarify the signal formation mechanism and guide the development of compact positive-ion detectors and nanodosimeters.

physics.ins-det↗

Impact of Environmental Stress on Low Gain Avalanche Diode Sensors Response

Low Gain Avalanche Diodes or LGADs are silicon sensors capable of achieving excellent timing resolution due to their characteristic internal gain. Detectors based on LGAD technology play a crucial role in High Energy and Nuclear Physics experiments, among other applications. However, their performance is affected by environmental factors such as temperature, humidity, and storage conditions. A systematic evaluation of the response of LGAD sensors as a function of these environmental parameters is therefore of essential importance for any application. LGAD sensors fabricated at the Brookhaven National Laboratory are characterized and stress-tested against various operating conditions, such as rapid temperature and humidity changes. Dedicated and detailed simulations are used to interpret the experimental results.

physics.ins-det↗

Design of an electrostatic violin mode damper for gravitational wave detector enhancement

The test mass suspension fiber resonances and their harmonics pollute the sensitivity of the detectors of the advanced Laser Interferometer Gravitational Wave Observatory (aLIGO) and cause operational issues. The current method of damping these violin modes requires the GW detector be locked; identifying modes after a test mass replacement takes valuable commissioning time, and modes which are close together in frequency are hard to distinguish and damp independently. We present the design, prototyping, and initial lab testing of an electrostatic violin mode damper: a compact sensor and actuator set next to the fiber to monitor and damp resonances. The design uses a split photodiode and LED integrated into a shadow sensor, and an electrostatic actuator. The device is vacuum compatible and its mechanical design is compatible with the suspension and surrounding cage of the advanced Laser Interferometer Gravitational Wave Observatory test masses. The shadow sensor has a shot noise limited displacement noise floor of 5e-11 {\meter\per\sqrt\hertz}, sufficient to measure the test mass violin modes when highly excited. The modeled actuator strength is 0.3 nN, meeting the requirements to damp the modes for the aLIGO suspensions.

physics.ins-det↗