SearcharxivSearch

arXiv · physics/0311060

Low-Cost Data Acquisition Card for School-Network Cosmic Ray Detectors

Abstract

The Cosmic Ray Observatory Project (CROP) at University of Nebraska/Lincoln and the Washington Area Large-scale Time coincidence Array (WALTA) at University of Washington/Seattle are among several outreach projects siting cosmic-ray detectors at local high schools in cities around North America, to study the origins and interactions of high-energy cosmic rays. In a collaboration between QuarkNet, the outreach program based at Fermilab, CROP, and WALTA, a low-cost data acquisition electronics card has been developed to collect and synchronize the data from each detector site. The cost for each card is under US$500 for parts, functionally replacing much more expensive electronics crates and modules at each high school site. The card has 4 analog discriminator inputs for photo-multiplier tube signals, a 4-channel Time-to-Digital converter for local coincidence and time-over-threshold measurements at 0.75 ns resolution, programmable trigger logic via a CPLD and microcontroller, and a built-in low-cost GPS receiver/antenna module (via external cable) to provide event trigger time stamps at better than 100 ns accuracy. Temperature sensors and a barometer are also integrated to record environmental data along with the counter data. The card connects to any PC or laptop via a standard RS-232 serial port for data output and control. The microcontroller and CPLD are field programmable and therefore make the card functionality flexible and easy to upgrade.

Explore related subjects

Keep this discovery

BibTeXRIS

Sten Hansen, Thomas Jordan, Terry Kiper, Dan Claes, Gregory Snow, Hans Berns, T. H. Burnett, Richard Gran, R. Jeffrey Wilkes. 2003-11-14. Low-Cost Data Acquisition Card for School-Network Cosmic Ray Detectors. https://doi.org/10.1109/tns.2004.829447

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det