Searcharxiv⌕ Search

arXiv · 2609.39400

Measurement of the $^{39}$Ar specific activity in atmospheric argon with DArT at the Canfranc Underground Laboratory

Abstract

We report the measurement of the $^{39}$Ar specific activity of atmospheric argon using DArT, a low-background single-phase liquid-argon detector read out by cryogenic silicon photomultipliers, at the Canfranc Underground Laboratory (LSC) in Spain. DArT was first filled with atmospheric argon and then with a sample of underground argon of known radioactivity from the DarkSide-50 experiment. The underground argon serves as a background reference in this measurement, making the result robust because we do not rely on background simulations. We measure the $^{39}$Ar specific activity with both a cut-and-count method and a binned maximum-likelihood fit, yielding consistent results. We obtain $a_{\text{AAr}}= 0.955 \pm 0.008~\text{Bq}/\text{kg}$. This result agrees with previous measurements from other experiments and provides the most precise determination of the $^{39}$Ar specific activity in atmospheric argon to date. It also validates DArT as a key component of the DArTInArDM experiment at LSC, which aims to measure the $^{39}$Ar activity of the argon extracted from deep underground wells in Colorado (USA) for the Darkside-20k and LEGEND-1000 experiments at Laboratori Nazionali del Gran Sasso in Italy.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P. Agnes, H. O. Back, S. Bharat, W. M. Bonivento, M. Boulay, M. Caboni, N. Canci, N. Cargioli, P. Castello, S. Cebrián, L. Consiglio, R. Crampton, D. Diaz Mairena, D. Franco, I. Fuente-Ortega, F. Gabriele, D. Gahan, C. Galbiati, P. Garcia Abia, T. Hessel, S. Horikawa, A. Ianni, G. Korga, M. Kuźniak, L. Luzzi, A. Marasciulli, M. Martínez, P. Organtini, A. Ortiz de Solórzano, R. Pavarani, P. Pegoraro, V. Pesudo Fortes, M. Razeti, O. U. Rehman, L. Romero, D. Sablone, E. Sánchez García, R. Santorelli, C. Seoane, J. Sosiak, S. Sulis, C. Tierney, S. Tullio, G. Vera Díaz. 2026-10-01. Measurement of the $^{39}$Ar specific activity in atmospheric argon with DArT at the Canfranc Underground Laboratory. https://arxiv.org/abs/2609.39400

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

State of the Art in Direct Dark Matter Detectors: Technologies, Performance, and Future Directions

Identifying the particle nature of dark matter remains one of the most significant challenges in modern physics. Direct detection experiments aim to observe rare scattering events between dark matter particles and terrestrial targets, a task that demands extreme background suppression and sensitivity to minute energy depositions. This review critically assesses the current experimental landscape, organizing detector technologies by the fundamental physical trade-offs that define their scientific reach. We contrast the multi-tonne scalability of noble-liquid Time Projection Chambers (TPCs), which currently define the sensitivity frontier for high-mass Weakly Interacting Massive Particles (WIMPs), with the precision of cryogenic semiconductors and Charge-Coupled Device (CCD)- based sensors, which dominate the search for low-mass and sub-GeV candidates. Special emphasis is placed on the role of advanced reconstruction pipelines and machine learning (ML) as integral components of detector performance. Finally, we discuss the strategic roadmap for the next decade as experiments approach the neutrino fog, where coherent elastic neutrino-nucleus scattering (CEνNS) produces an increasingly significant and ultimately irreducible background that can mimic DM-induced nuclear recoils. We argue that future progress will rely not on a single technology but on a complementary global program combining increased target mass, ultra-low energy thresholds, improved background discrimination, and distinct observables - such as directionality and temporal signatures - to maintain robust discovery capability in the presence of neutrino-induced backgrounds.

physics.ins-det↗

Photoluminescence of resin-based solder flux residue under ultraviolet excitation from 120 nm to 310 nm

Nuisance photoluminescence is a potential source of background in particle detectors that use noble liquids as target material for galactic dark matter particles and neutrinos. Liquid argon and xenon scintillate in the vacuum ultraviolet (VUV) wavelength range in response to particle interactions. Photoluminescent materials that absorb these photons can cause unexpected signals that may impede event reconstruction in these detectors. We illuminated residue from different types of commercial solder flux commonly used in liquid xenon detectors with ultraviolet and VUV light and measured their photoluminescence spectra and intensities. We find that all tested flux residues photoluminesce in the visible spectral region when exposed to VUV light.

physics.ins-det↗

Development of Neutron Transmutation Doped Germanium (NTD-Ge) for Cryogenic Applications

This paper presents the systematic fabrication and characterization of cryogenic thermometers based on neutron transmutation-doped germanium (NTD-Ge). High-purity (10N) germanium samples were irradiated by thermal neutrons with different fluences at the China Advanced Research Reactor (CARR). After irradiation and a six-month cooling-down period, positron annihilation lifetime spectroscopy and temperature-dependent Hall effect measurements were performed to characterize irradiation-induced defects and carrier concentrations in the NTD-Ge samples. Utilizing standard semiconductor fabrication techniques, point electrodes were deposited onto the processed samples to fabricate functional NTD-Ge cryogenic thermometers. The low-temperature resistance performance of the devices was characterized down to 20 mK on a millikelvin range cryogenic test platform. The measured temperature dependence of resistance follows Mott's law, showing excellent agreement across the full measured range. The extracted T0 is consistent with expectations. These results collectively verified both the applicability of the thermometers in cryogenic system and the reliability of the fabrication procedure.

physics.ins-det↗