SearcharxivSearch

arXiv · 2309.11996

Design and performance of the field cage for the XENONnT experiment

Abstract

The precision in reconstructing events detected in a dual-phase time projection chamber depends on an homogeneous and well understood electric field within the liquid target. In the XENONnT TPC the field homogeneity is achieved through a double-array field cage, consisting of two nested arrays of field shaping rings connected by an easily accessible resistor chain. Rather than being connected to the gate electrode, the topmost field shaping ring is independently biased, adding a degree of freedom to tune the electric field during operation. Two-dimensional finite element simulations were used to optimize the field cage, as well as its operation. Simulation results were compared to ${}^{83m}\mathrm{Kr}$ calibration data. This comparison indicates an accumulation of charge on the panels of the TPC which is constant over time, as no evolution of the reconstructed position distribution of events is observed. The simulated electric field was then used to correct the charge signal for the field dependence of the charge yield. This correction resolves the inconsistent measurement of the drift electron lifetime when using different calibrations sources and different field cage tuning voltages.

Explore related subjects

Keep this discovery

BibTeXRIS

E. Aprile, K. Abe, S. Ahmed Maouloud, L. Althueser, B. Andrieu, E. Angelino, J. R. Angevaare, V. C. Antochi, D. Antón Martin, F. Arneodo, L. Baudis, A. L. Baxter, M. Bazyk, L. Bellagamba, R. Biondi, A. Bismark, E. J. Brookes, A. Brown, S. Bruenner, G. Bruno, R. Budnik, T. K. Bui, C. Cai, J. M. R. Cardoso, D. Cichon, A. P. Cimental Chávez, A. P. Colijn, J. Conrad, J. J. Cuenca-García, J. P. Cussonneau, V. DÁndrea, M. P. Decowski, P. Di Gangi, S. Diglio, K. Eitel, A. Elykov, S. Farrell, A. D. Ferella, C. Ferrari, H. Fischer, M. Flierman, W. Fulgione, C. Fuselli, P. Gaemers, R. Gaior, A. Gallo Rosso, M. Galloway, F. Gao, R. Glade-Beucke, L. Grandi, J. Grigat, H. Guan, M. Guida, R. Hammann, A. Higuera, C. Hils, L. Hoetzsch, N. F. Hood, J. Howlett, M. Iacovacci, Y. Itow, J. Jakob, F. Joerg, A. Joy, M. Kara, P. Kavrigin, S. Kazama, M. Kobayashi, G. Koltman, A. Kopec, F. Kuger, H. Landsman, R. F. Lang, L. Levinson, I. Li, S. Li, S. Liang, S. Lindemann, M. Lindner, K. Liu, J. Loizeau, F. Lombardi, J. Long, J. A. M. Lopes, Y. Ma, C. Macolino, J. Mahlstedt, A. Mancuso, L. Manenti, F. Marignetti, T. Marrodán Undagoitia, K. Martens, J. Masbou, D. Masson, E. Masson, S. Mastroianni, M. Messina, K. Miuchi, A. Molinario, S. Moriyama. 2023-09-21. Design and performance of the field cage for the XENONnT experiment. https://doi.org/10.1140/epjc%2Fs10052-023-12296-y

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Production of Light Nuclei and Hypernuclei in Heavy-Ion Collisions

We review recent STAR and ALICE measurements of light-nucleus and hypernucleus yields, femtoscopic correlations, and collective flow presented at SQM 2026. Statistical-hadronization calculations provide a useful baseline for integrated yields but do not simultaneously describe all measured light-nucleus ratios across collision energies and system sizes. For bound states with mass number $A<4$, current coalescence calculations provide a broadly consistent description of yields, femtoscopic correlations, and collective flow, although the quantitative hypertriton comparison depends on the assumed few-body wave function. The suppressed production of resonant $^{4}$Li relative to compact $^{4}$He indicates an effect of nuclear structure and late-stage dynamics. However, the quantitative model comparison also depends on the treatment of feed-down from unstable states. In high-multiplicity $p$+$p$ collisions, pion-deuteron femtoscopy further indicates that most observed (anti)deuterons are formed through nucleon fusion after strong decays of short-lived resonances. Taken together, these measurements show that production chronology and internal nuclear structure leave measurable imprints on the physics observables.

hep-ex

Search for the process $e^+e^-\to f_1(1285)$ at the SND detector

In the experiment with the SND detector at the VEPP-2000 $e^+e^-$ collider, a search is performed for the direct production of the $C$-even $f_1(1285)$ resonance in $e^+e^-$ collisions. The analysis is based on data with an integrated luminosity of about 200 pb$^{-1}$, accumulated in the center-of-mass energy range of 1.14--1.46 GeV, of which about 72 pb$^{-1}$ were recorded near the maximum of the $f_1(1285)$ resonance. The $f_1(1285)$ production cross section at the resonance maximum $\sigma(e^+e^-\to f_1)=(31\pm 13\pm 2)$ pb and the branching fraction $B(f_1(1285)\to e^+e^-)=(3.5\pm 1.4\pm 0.3)\times 10^{-9}$ have been measured. The significance of the observation of the $e^+e^-\to f_1(1285)$ process is $2.5\sigma$. Since the significance is low, we also present the upper limits at the 90% confidence level: $\sigma(e^+e^-\to f_1)<48\mbox{ pb}$ and $B(f_1(1285)\to e^+e^-)<5.4\times 10^{-9}$.

hep-ex

Projected Sensitivity to Slow Muonphilic Dark Matter with Accelerator Muon Beams

The nature of dark matter (DM) remains one of the most enduring open questions in modern physics, and muonphilic DM has emerged as a promising scenario that complements traditional DM candidates. Following the recently established cosmic-ray muon scattering approach, we investigate the sensitivity for probing slow muonphilic DM with accelerator muon beams. A Geant4-based simulation framework is developed, incorporating the detector geometry from the PKMu muon tomography system and a dedicated elastic $\mu$-DM scattering process. The projected sensitivity is found to be largely insensitive to both the beam energy and the transverse beam size when the beam is fully contained within the detector acceptance. For a benchmark beam intensity of $10^5/\rm{s}$, the simulated pure-muon beam surpasses the existing cosmic-ray limit of $1.61\times10^{-17}$ cm$^2$ at $m_{\rm DM}=1$ GeV within approximately 11 seconds. A realistic muon beam phase-space distribution based on simulations for the High Intensity heavy-ion Accelerator Facility (HIAF) is also implemented, yielding projected limits that improve upon the cosmic-ray results by nearly two orders of magnitude in a one-day exposure. These results demonstrate that a beam-muon scattering experiment offers a robust and promising route toward significantly improved sensitivity to slow muonphilic DM.

hep-ex