SearcharxivSearch

arXiv subjects

M. Kuźniak

Publications and source records attributed to M. Kuźniak.

At least 19 recordsLinked to original sources

Measurement of the muon flux at SNOLAB using the DEAP-3600 experiment

A direct measurement of the muon flux at SNOLAB is performed using the DEAP-3600 experiment, located 2 km underground at SNOLAB near Sudbury, Canada. Primarily designed for the direct detection of weakly interacting massive particles (WIMPs), a dark matter candidate, DEAP-3600 consists of an inner spherical acrylic vessel containing a liquid argon target; this vessel is enclosed within a steel shell which is submerged in an instrumented water tank, serving as a muon veto for the dark matter search. The muon flux measurement is performed using a cut-and-count analysis of events observed in the muon veto detector and of events which are coincident between the muon veto and the liquid argon target. The requirement that muons traverse both the water and liquid argon minimizes instrumental backgrounds and systematic uncertainties. Using data collected from November 2016 to March 2020, the muon flux is measured by this coincidence analysis to be $(3.71 \pm 0.25_{\textrm{stat}} \pm 0.09_{\textrm{sys}}) \times 10^{-10}\, μ/$cm$^2$/s. The standalone measurement using muon veto data only is compatible within uncertainties. Both measurements agree with the previous result by the SNO experiment and with simulations carried out using the MUTE software. These results provide an important benchmark for future rare-event searches at the SNOLAB facility.

hep-ex

First evidence of neutrino absorption on argon using $^{8}$B solar neutrinos in DEAP-3600

We report experimental evidence for electron neutrino charged-current interactions (neutrino absorption, CC $ν_e$) from $^{8}$B solar neutrinos on $^{40}$Ar using an exposure of ($7.29 \pm 0.05$) tonne$\cdot$years in the DEAP-3600 detector. A region of interest (ROI) of 10.5-13.0 MeV reconstructed energy calibrated on single-peak events, corresponding to incident neutrino energy in 12.0-14.5 MeV, is used for this measurement. We observe 5 single-peak and 1 double-peak neutrino-like events consistent with the $^{8}$B solar neutrino energy spectrum in the ROI after correcting for nonlinearities in the detector response at high energies. With an expected background of $0.48~^{+0.16}_{-0.15}$ events, the data correspond to a significance of $4.0\,σ$ with respect to the background-only hypothesis. We report an energy-averaged cross section of $(4.0~^{+2.0}_{-1.6}~\mathrm{(stat)}~^{+0.8}_{-0.7}~\mathrm{(sys)})\times 10^{-41}\,\mathrm{cm}^2$ in the ROI for the CC $ν_{e}$ signal, a factor $(2.4~^{+1.3}_{-1.0})$ higher than predicted by Bhattacharya, Goodman and García (2009).

hep-ex

Dark Matter Search with the DEAP-3600 Detector using the Profile Likelihood Ratio Method

We present here a search for WIMP dark matter using 790.8 live-days of data collected with 3269 kg of liquid argon (1266 kg fiducial) by the DEAP-3600 detector at SNOLAB, using the Profile Likelihood Ratio method. The likelihood model is based on three parameters: estimated energy, pulse-shape discrimination parameter, and reconstructed position within the detector. Using this method, the expected signal sensitivity of DEAP-3600 benefits from an increased fiducial volume and improved event selection acceptance. Alpha-decays from a small number of dust particulates circulating within the liquid argon target are the dominant source of background events and limit the sensitivity of this search. This result provides improved exclusion upper limits on the WIMP-nucleon spin-independent cross section on liquid argon for WIMP masses between 20 GeV/$c^{2}$ and 100 GeV/$c^{2}$. At 100 GeV/$c^{2}$ the observed limit is 3.4 $\times$ 10$^{-45}$ cm$^2$ at 90% confidence level.

hep-ex

Characterization of argon recoils at the keV scale with ReD and ReD+

The ReD experiment measured the ionization yield Qy of argon for nuclear recoils in the 2-10 keV range using a dual-phase Time Projection Chamber irradiated with neutrons from a Cf-252 fission source. The measurement extends coverage below 7 keV, confirms consistency with previous data above 7 keV, and indicates a higher Qy at lower energies. These results are relevant for argon-based experiments searching for dark matter in the form of low-mass Weakly Interacting Massive Particles, which are very sensitive to the modeling of the detector response in this energy range.

hep-ex

Production of GEM-like structures for cryogenic applications, using laser-cutting techniques

A novel concept for electroluminescence (EL) structures was recently proposed. In it, a wavelength-shifting material is deposited inside the holes of GEM-like structures which, after suitable optical treatment of its electrodes, improves the light collection and detection efficiency in noble gas TPCs. This new development directly addresses problems related with the scalability of future dual-phase TPCs for rare-event searches, matching (and potentially exceeding) the performance of conventional EL techniques. We report the newest developments on the production of such structures using laser-based techniques, namely the manufacture of a first batch of the so-called FAT-GEMs. This process allows low-cost and reproducible manufacturing of a high volume of such structures. In addition to the detailed description of the production, we present a performance assessment in pure argon, at a gas density close to the one expected in LAr conditions. An energy resolution of 23.5$\pm$1~\% (FWHM) at 5.9~keV was obtained, indicating a consistent improvement over previous batch. The optical treatment of the electrode surfaces has been greatly simplified and modestly improved, while charging-up effects arising from the use of laminates eliminated.

physics.ins-det

Position Reconstruction in the DEAP-3600 Dark Matter Search Experiment

In the DEAP-3600 dark matter search experiment, precise reconstruction of the positions of scattering events in liquid argon is key for background rejection and defining a fiducial volume that enhances dark matter candidate events identification. This paper describes three distinct position reconstruction algorithms employed by DEAP-3600, leveraging the spatial and temporal information provided by photomultipliers surrounding a spherical liquid argon vessel. Two of these methods are maximum-likelihood algorithms: the first uses the spatial distribution of detected photoelectrons, while the second incorporates timing information from the detected scintillation light. Additionally, a machine learning approach based on the pattern of photoelectron counts across the photomultipliers is explored.

physics.ins-det

Relative Measurement and Extrapolation of the Scintillation Quenching Factor of $α$-Particles in Liquid Argon using DEAP-3600 Data

The knowledge of scintillation quenching of $α$-particles plays a paramount role in understanding $α$-induced backgrounds and improving the sensitivity of liquid argon-based direct detection of dark matter experiments. We performed a relative measurement of scintillation quenching in the MeV energy region using radioactive isotopes ($^{222}$Rn, $^{218}$Po and $^{214}$Po isotopes) present in trace amounts in the DEAP-3600 detector and quantified the uncertainty of extrapolating the quenching factor to the low-energy region.

physics.ins-det

Direct Measurement of the $^{39}$Ar Half-life from 3.4 Years of Data with the DEAP-3600 Detector

The half-life of $^{39}$Ar is measured using the DEAP-3600 detector located 2 km underground at SNOLAB. Between 2016 and 2020, DEAP-3600 used a target mass of (3269 $\pm$ 24) kg of liquid argon distilled from the atmosphere in a direct-detection dark matter search. Such an argon mass also enables direct measurements of argon isotope properties. The decay of $^{39}$Ar in DEAP-3600 is the dominant source of triggers by two orders of magnitude, ensuring high statistics and making DEAP-3600 well-suited for measuring this isotope's half-life. Use of the pulse-shape discrimination technique in DEAP-3600 allows powerful discrimination between nuclear recoils and electron recoils, resulting in the selection of a clean sample of $^{39}$Ar decays. Observing over a period of 3.4 years, the $^{39}$Ar half-life is measured to be $(302 \pm 8_{\rm stat} \pm 6_{\rm sys})$ years. This new direct measurement suggests that the half-life of $^{39}$Ar is significantly longer than the accepted value, with potential implications for measurements using this isotope's half-life as input.

nucl-ex

Characterization of spurious-electron signals in the double-phase argon TPC of the DarkSide-50 experiment

Spurious-electron signals in dual-phase noble-liquid time projection chambers have been observed in both xenon and argon Time Projection Chambers (TPCs). This paper presents the first comprehensive study of spurious electrons in argon, using data collected by the DarkSide-50 experiment at the INFN Laboratori Nazionali del Gran Sasso (LNGS). Understanding these events is a key factor in improving the sensitivity of low-mass dark matter searches exploiting ionization signals in dual-phase noble liquid TPCs. We find that a significant fraction of spurious-electron events, ranging from 30 to 70% across the experiment's lifetime, are caused by electrons captured from impurities and later released with delays of order 5-50 ms. The rate of spurious-electron events is found to correlate with the operational condition of the purification system and the total event rate in the detector. Finally, we present evidence that multi-electron spurious electron events may originate from photo-ionization of the steel grid used to define the electric fields. These observations indicate the possibility of reduction of the background in future experiments and hint at possible spurious electron production mechanisms.

hep-ex

New candidate polymeric wavelength shifters for noble liquid detectors

Polymeric wavelength shifters are of particular interest for large liquid argon detectors. Inspired by the success of polyethylene naphthalate (PEN), other new polymers exhibiting a similar type of excimer fluorescence were investigated. We report on the preliminary results of the first cryogenic wavelength shifting test of a solution-cast film of PVN, poly(2-vinyl naphthalene). Significant brittleness was identified as a factor potentially limiting the use of PVN. However, clear signs of wavelength shifting were observed, with the overall efficiency and time response comparable to those of PEN.

astro-ph.IM

Demonstration of the light collection stability of a PEN-based wavelength shifting reflector in a tonne scale liquid argon detector

Liquid argon detectors rely on wavelength shifters for efficient detection of scintillation light. The current standard is tetraphenyl butadiene (TPB), but it is challenging to instrument on a large scale. Poly(ethylene 2,6-naphthalate) (PEN), a polyester easily manufactured as thin sheets, could simplify the coverage of large surfaces with wavelength shifters. Previous measurements have shown that commercial grades of PEN have approximately 50% light conversion efficiency relative to TPB. Encouraged by these results, we conducted a large-scale measurement using $4~m^2$ combined PEN and specular reflector foils in a two-tonne liquid argon dewar to assess its stability over approximately two weeks. This test is crucial for validating PEN as a viable substitute for TPB. The setup used for the measurement of the stability of PEN as a wavelength shifter is described, together with the first results, showing no evidence of performance deterioration over a period of 12 days.

physics.ins-det

Search for dark matter annual modulation with DarkSide-50

Dark matter induced event rate in an Earth-based detector is predicted to show an annual modulation as a result of the Earth's orbital motion around the Sun. We searched for this modulation signature using the ionization signal of the DarkSide-50 liquid argon time projection chamber. No significant signature compatible with dark matter is observed in the electron recoil equivalent energy range above $40~{\rm eV_{ee}}$, the lowest threshold ever achieved in such a search.

hep-ex

Production of GEM-like structures using laser-cutting techniques

To enhance the ionization yield of liquid argon time projection chambers (LArTPC) used in dark matter and neutrino experiments it was proposed the use of dopants in LAr, with ionization energies below the scintillation threshold of Ar. While dual-phase LArTPCs have excellent sensitivity to single ionization electrons, their compatibility with photosensitive dopants is hindered by gas-phase electroluminescence photons ionizing the dopants, leading to a positive feedback loop. This can be addressed by optically decoupling the gaseous and liquid phases with a barrier that transmits electrons. A possible solution relies on the use of a pair of structures based on Gaseous Electron Multipliers(GEMs) with misaligned holes. Rather than amplifying electron signals in gas pockets within their holes, their holes will be filled with LAr and a low biasing voltage, so that incident drifting electrons are drawn into the holes but not amplified. Instead, amplification will occur in the gas phase above the structures. Its core element is a GEM-like structure machined from polyethylene naphthalate(PEN). Since PEN scintillates in the visible spectrum, the risk of increased radioactivity due to the larger mass compared to traditional wire grids is negated by the potential to veto its own radioactivity. As such, these structures may also be a useful alternative to wire grids. In this work, we report the newest developments on the production of GEM-like structures using laser-based techniques, namely the manufacture of the first batch PEN and PMMA-based GEM-like structures. This process allows low-cost, reproducible fabrication of a high volume of such structures. In addition to being a low radioactive technique, we expect that it will allow the scaling up of the production of these structures at a reduced cost. First tests indicate good electrical stability, while the performance assessment is still ongoing.

physics.ins-det

Long-term temporal stability of the DarkSide-50 dark matter detector

The stability of a dark matter detector on the timescale of a few years is a key requirement due to the large exposure needed to achieve a competitive sensitivity. It is especially crucial to enable the detector to potentially detect any annual event rate modulation, an expected dark matter signature. In this work, we present the performance history of the DarkSide-50 dual-phase argon time projection chamber over its almost three-year low-radioactivity argon run. In particular, we focus on the electroluminescence signal that enables sensitivity to sub-keV energy depositions. The stability of the electroluminescence yield is found to be better than 0.5%. Finally, we show the temporal evolution of the observed event rate around the sub-keV region being consistent to the background prediction.

hep-ex

Development of wavelength-shifting PEN foils for next generation experiments

Polyethylene naphthalate (PEN) foils have been demonstrated as a wavelength shifter suitable for operation in liquid argon. At the same time, wavelength shifting efficiency of technical grades of PEN, commercially available on the market, is lower than that of tetraphenyl butadiene (TPB). This paper reports on an R&D program focused on exploring the intrinsic limitations of PEN and optimizing it for the highest achievable wavelength shifting efficiency.

astro-ph.IM

FAT-GEMs: (Field Assisted) Transparent Gaseous-Electroluminescence Multipliers

The idea of implementing electroluminescence-based amplification through transparent multi-hole structures (FAT-GEMs) has been entertained for some time. Arguably, for such a technology to be attractive it should perform at least at a level comparable to conventional alternatives based on wires or meshes. We present now a detailed calorimetric study carried out for 5.9~keV X-rays in xenon, for pressures ranging from 2 to 10~bar, resorting to different geometries, production and post-processing techniques. At a reference voltage 5~times above the electroluminescence threshold ($E_{EL,th}\sim0.7$~kV/cm/bar), the number of photoelectrons measured for the best structure was found to be just 18\%~below that obtained for a double-mesh with the same thickness and at the same distance. The energy resolution stayed within 10\% (relative) of the double-mesh value. An innovative characteristic of the structure is that vacuum ultraviolet (VUV) transparency of the polymethyl methacrylate (PMMA) substrate was achieved, effectively, through tetraphenylbutadiene (TPB) coating of the electroluminescence channels combined with indium tin oxide (ITO) coating of the electrodes. This resulted in a $\times 2.25$-increased optical yield (compared to the bare structure), that was found to be in good agreement with simulations if assuming a TPB wavelength-shifting-efficiency at the level of WLSE=0.74-1.28, compatible with expected values. This result, combined with the stability demonstrated for the TPB coating under electric field (over 20~h of continuous operation), shows great potential to revolutionize electroluminescence-based instrumentation.

physics.ins-det

Cryogenic setup for the characterization of wavelength-shifting materials for noble element radiation detectors

In the present work, we describe a cryogenic setup for studies of wavelength-shifting materials for optimised light collection in noble element radiation detectors, and discuss the commissioning results. This SiPM-based setup uses alpha induced scintillation in gaseous argon as the vacuum ultraviolet light source with the goal of characterising materials, such as polyethylene naphthalate (PEN) and tetraphenyl butadiene (TPB), in terms of their wavelength-shifting efficiency. Further extensions of the system are currently being studied. The foreseen upgrades are expected to allow the study of GEM-like structures potentially interesting for rare-event searches. The design of the setup will be addressed along with the first results.

physics.ins-det

Precision Measurement of the Specific Activity of $^{39}$Ar in Atmospheric Argon with the DEAP-3600 Detector

The specific activity of the beta decay of $^{39}$Ar in atmospheric argon is measured using the DEAP-3600 detector. DEAP-3600, located 2 km underground at SNOLAB, uses a total of (3269 $\pm$ 24) kg of liquid argon distilled from the atmosphere to search for dark matter. This detector with very low background uses pulseshape discrimination to differentiate between nuclear recoils and electron recoils and is well-suited to measure the decay of $^{39}$Ar. With 167 live-days of data, the measured specific activity at the time of atmospheric extraction is [0.964 $\pm$ 0.001 (stat) $\pm$ 0.024 (sys)] Bq/kg$_{\rm atmAr}$ which is consistent with results from other experiments. A cross-check analysis using different event selection criteria provides a consistent result.

physics.ins-det