SearcharxivSearch

arXiv · 1909.12779

Plasma Profiling Time-of-Flight Mass Spectrometry for Fast Elemental Analysis of Semiconductor Structures with Depth Resolution in the Nanometer Range

Abstract

Plasma profiling time of flight mass spectrometry (PP-TOFMS) has recently gained interest, as it enables the elemental profiling of semiconductor structures with high depth resolution in short acquisition times. As recently shown by Tempez et al., PP-TOFMS can be used to obtain the composition in the structures for modern field effect transistors [1]. There, the results were compared to conventional SIMS measurements. In the present study, we compare PP-TOFMS measurements of an Al-/In-/GaN quantum well multi stack to established micro- and nano-analysis techniques like cathodoluminescence (CL), scanning transmission electron microscopy (STEM), energy dispersive X-ray spectroscopy (EDX) and X-ray diffraction (XRD). We show that PP-TOFMS is able to resolve the layer structure of the sample even more than 500 nm deep into the sample and allows the determination of a relative elemental composition with an accuracy of about 10 rel. %. Therefore, it is an extremely rapid alternative method to obtain semiconductor elemental depth profiles without expensive and time consuming sample preparation as it is needed for TEM. Besides, PP-TOFMS offers better depth resolution and more elemental information than for example electrochemical capacitance-voltage (ECV), as the acquisition of all elements occurs in parallel and not only electrically (ECV) or optically (CL) active elements are observed.

Explore related subjects

Keep this discovery

BibTeXRIS

Hendrik Spende, Christoph Margenfeld, Tobias Meyer, Irene Manglano Clavero, Heiko Bremers, Andreas Hangleiter, Michael Seibt, Andreas Waag, Andrey Bakin. 2019-09-27. Plasma Profiling Time-of-Flight Mass Spectrometry for Fast Elemental Analysis of Semiconductor Structures with Depth Resolution in the Nanometer Range. https://doi.org/10.1088/1361-6641/ab6ac0

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Janus Dipoles: Fundamentals, Realizations, and Emerging Applications

The Janus dipole - featuring orthogonally oriented electric and magnetic dipoles with a 90-degree phase difference - has emerged as a powerful paradigm for wave manipulation. Unlike traditional Huygens dipoles used for directional control, this unique configuration exhibits strongly asymmetric, face-selective near-field behavior while maintaining a quasi-isotropic far-field radiation pattern. These remarkable properties make the Janus dipole an essential platform for directional wave shaping, with wide-ranging applications in on-chip photonics, quantum interactions, and wireless power transfer. This review systematically traces the rapid development of the Janus dipole from its foundational theoretical inception to its diverse implementation platforms across optical, microwave, and acoustic frequencies. In this paper, we explore the governing principles, classify realization strategies into passive Janus dipoles, active Janus dipoles, and advanced near-field coupling control, and highlight emerging frontiers. By bridging foundational electrodynamics with advanced device engineering, this paper serves as an essential reference and roadmap for researchers designing next-generation, highly integrated, and compact wave-manipulation systems.

physics.app-ph

Scattering-robust Imaging of Azimuthal Features with Enhanced Resolution

Imaging through scattering media remains a long-standing challenge in numerous real-world applications, ranging from medical imaging to long-distance sensing. Recently, illumination consisting of a single orbital angular momentum (OAM) mode, which is structured in the azimuthal coordinate, has been shown to provide enhanced resolution for imaging objects with azimuthal features, with the resolution becoming maximum at an optimal OAM value. However, in the presence of scattering, single-mode fields, which are spatially fully coherent, cause the imaging resolution to decrease significantly due to speckle formation. In this work, we employ azimuthally partially coherent fields and experimentally demonstrate imaging of azimuthal features with enhanced resolution in the presence of scattering. We show that lower degree of azimuthal coherence in such illumination leads to increased robustness against scattering while the azimuthal structure of the illumination ensures enhanced resolution. We derive the condition for best imaging resolution, and we report increase of imaging contrast in scattering from about 7% to 50% as the illumination is changed from a single-mode fully coherent field to that of an azimuthal partially coherent field.

physics.app-ph

Influence of magnetic fields on the performance of spin-orbit torque magnetic random-access memory

Spin-orbit torque magnetic random-access memory (SOT-MRAM) offers high speed, ultrahigh endurance, and compatibility with advanced semiconductor processes, making it a promising candidate for next-generation nonvolatile memory. However, intrinsic bias fields in magnetic tunnel junctions (MTJs), originating from reference-layer stray fields and interlayer coupling, cause asymmetric critical switching currents and increased energy consumption. Existing compensation approaches usually introduce additional magnetic layers into the MTJ stack, which increases fabrication complexity and limits wafer-scale integration. Here, we propose a bias-compensation strategy without modifying the MTJ stack by engineering local stray magnetic fields through magnetic filling materials in vertical interconnect access (VIA) channels during the back-end-of-line process. Micromagnetic simulations show that the proposed magnetic filling layer can provide the required auxiliary field for deterministic switching and significantly suppress write-current asymmetry. By optimizing the MTJ position relative to the magnetic filling structure, the write-current bias ratio is reduced from 21.6% in the conventional design to 1.3%. The approach is also applicable to in-plane magnetic anisotropy SOT-MTJs, reducing the bias ratio from 19.8% to -0.2%. Scaling analysis further demonstrates that the compensation effect remains effective when the device size is reduced to 20% of the original dimension (MTJ diameter approximately 10 nm), indicating its potential for high-density SOT-MRAM integration.

physics.app-ph