SearcharxivSearch

arXiv · 2011.03815

Remote Configuration of the ProASIC3 on the ALICE Inner Tracking System Readout Unit

Abstract

A Large Ion Collider Experiment (ALICE) is one of the four major experiments conducted at the CERN Large Hadron Collider (LHC). The ALICE detector is currently undergoing an upgrade for the upcoming Run 3 at the LHC. The new Inner Tracking System (ITS) sub-detector is part of this upgrade. The front-end electronics of the ITS is composed by 192 Readout Units, installed in a radiation environment. Single Event Upsets (SEUs) in the SRAM-based Xilinx Kintex Ultrascale FPGAs used in the ITS readout represent a real concern. To clear SEUs affecting the Kintex configuration memory, a secondary Flash-based Microsemi ProASIC3E (PA3) FPGA is used. This device configures and continuously scrubs the Xilinx FPGA while data-taking is ongoing, which avoids accumulation of SEUs. The communication path to the RUs is via the radiation hard Gigabit Transceiver (GBT) system on 100 m long optical links. The PA3 is reachable via the GBT Slow Control Adapter (GBT-SCA) ASIC using a dedicated JTAG bus driving channel. During the course of Run 3, it is foreseeable that the FPGA design of the PA3 will require upgrades to correct possible issues and add new functionality. It is therefore mandatory that the PA3 itself can be configured remotely, for which a dedicated software tool is needed. This paper presents the design and implementation of the distributed tools to re-configure remotely the PA3 FPGAs.

Explore related subjects

Keep this discovery

BibTeXRIS

Shiming Yuan, Johan Alme, Dieter Röhrich, Matthias Richter, Magnus Rentsch Ersdal, Piero Giubilato, Gianluca Aglieri Rinella, Arild Velure, Matteo Lupi, Johann Joachim Schambach. 2020-11-07. Remote Configuration of the ProASIC3 on the ALICE Inner Tracking System Readout Unit. https://arxiv.org/abs/2011.03815

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det