SearcharxivSearch

arXiv · 2301.03912

MALTA-Cz: A radiation hard full-size monolithic CMOS sensor with small electrodes on high-resistivity Czochralski substrate

Abstract

Depleted Monolithic Active Pixel Sensor (DMAPS) sensors developed in the Tower Semiconductor 180 nm CMOS imaging process have been designed in the context of the ATLAS ITk upgrade Phase-II at the HL-LHC and for future collider experiments. The "MALTA-Czochralski (MALTA-Cz)" full size DMAPS sensor has been developed with the goal to demonstrate a radiation hard, thin CMOS sensor with high granularity, high hit-rate capability, fast response time and superior radiation tolerance. The small pixel size ($36.4\times 36.4$~$\mu$m$^2$) provides high spatial resolution. Its asynchronous readout architecture is designed for high hit-rates and fast time response in triggered and trigger-less detector applications. The readout architecture is designed to stream all hit data to the multi-channel output which allows an off-sensor trigger formation and the use of hit-time information for event tagging. The sensor manufacturing has been optimised through process adaptation and special implant designs to allow the manufacturing of small electrode DMAPS on thick high-resistivity p-type Czochralski substrate. The special processing ensures excellent charge collection and charge particle detection efficiency even after a high level of radiation. Furthermore the special implant design and use of a Czochralski substrate improves the sensor's time resolution. This paper presents a summary of sensor design optimisation through process and implant choices and TCAD simulation to model the signal response. Beam and laboratory test results on unirradiated and irradiated sensors have shown excellent detection efficiency after a dose of $2\times10^{15}$ 1 MeV n$_{eq}$/cm$^{2}$. The time resolution of the sensor is measured to be $\sigma=2$~ns.

Explore related subjects

Keep this discovery

BibTeXRIS

H. Pernegger, P. Allport, D. V. Berlea, A. Birman, D. Bortoletto, C. Buttar, E. Charbon, F. Dachs, V. Dao, H. Denizli, D. Dobrijevic, M. Dyndal, A. Fenigstein, L. Flores Sanz de Acedo, P. Freeman, A. Gabrielli, M. Gazi, L. Gonella, V. Gonzalez, G. Gustavino, A. Haim, T. Kugathasan, M. LeBlanc, M. Munker, K. Y. Oyulmaz, F. Piro, P. Riedler, H. Sandaker, E. J. Schioppa, A. Sharma, W. Snoeys, C. Solans Sanchez, T. Suligoj, E. Toledano, M. van Rijnbach, M. Vazquez Nunez, J. Weick, S. Worm, A. M. Zoubir. 2023-01-10. MALTA-Cz: A radiation hard full-size monolithic CMOS sensor with small electrodes on high-resistivity Czochralski substrate. https://doi.org/10.1088/1748-0221%2F18%2F09%2Fp09018

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det