SearcharxivSearch

arXiv subjects

Xiaoshan Jiang

Publications and source records attributed to Xiaoshan Jiang.

At least 19 recordsLinked to original sources

SuperEM: A Sub-meV Threshold Detector Architecture for Cosmic Neutrino Background and Dark Matter Detection

Expanding the operational boundaries of radiation detection is imperative for contemporary particle physics, astrophysics, and cosmology. At this frontier, the direct detection of the Cosmic Neutrino Background (C$ν$B), the determination of the absolute neutrino mass scale, and the search for sub-GeV Light Dark Matter (LDM) necessitate detector architectures capable of sub-millielectronvolt (sub-meV) energy thresholds, exceptional absolute energy resolution, fast time response, and massive scalability. Current technologies confront an intrinsic limit---the ``impossible triangle''---wherein optimizing for sub-meV thresholds inherently compromises either macroscopic timing response or spatial scalability. Here, we introduce the Superconductor-Coupled Semiconductor Electron-Multiplying (SuperEM) detector, a fundamentally novel structural paradigm designed to bypass this limitation. The architecture couples the ultra-low energy threshold of a superconducting absorber with the intrinsic high-gain digitization of a strongly biased, high-density semiconductor P-N junction. Incident energy yields a proliferation of non-equilibrium quasiparticles, which are subsequently extracted via quantum tunneling across an ultra-thin Atomic Layer Deposition (ALD) insulating barrier. Building upon our prior empirical validation of deep-cryogenic avalanche mechanics, this manuscript establishes the fundamental theoretical feasibility and structural foundation of the complete device. Signal transport simulations confirm that an undoped interface coupled with a strong drift field enables highly efficient, nanosecond-scale transient electron drift, resolving completely within 35 ns. The SuperEM architecture thus constitutes a scalable, high-resolution, and fast time-response framework for next-generation C$ν$B and LDM observatories.

hep-ex

Test of the JUNO 20-inch PMTs during Installation

Photomultiplier tubes (PMTs) are widely used in neutrino experiments. As a new-generation neutrino observatory, JUNO requires an excellent energy resolution of 3% at 1 MeV. This will be realized with a 20 kton liquid scintillator detector instrumented with more than 20000 20-inch PMTs and 25600 3-inch PMTs. These PMTs were successfully installed in JUNO from October 2022 to December 2024. During the installation, seven test campaigns were performed to validate the PMT functionality, including measurements dark count rate, gain, waveform, and charge spectrum. In this paper, we present the implementation of these tests and the corresponding results for the 20-inch PMTs throughout the installation process.

physics.ins-det

A High-Precision Clock Synchronization System for the CEPC Accelerator

The Circular Electron Positron Collider (CEPC) distributes a reference clock distributed to 192 control nodes along its 100~km underground tunnel. The required synchronization precision is 30~ps (standard deviation). We present an enhanced White Rabbit (WR)-based clock synchronization system designed to meet this requirement. A noise-budget analysis of the standard WR slave loop identifies the analog actuation chain (DAC + VCXO + multiplier PLL) and restart-induced timing uncertainty as the dominant limitations. In our redesigned node, the DAC+VCXO chain is replaced by a Si5345A DSPLL clock generator with DCO-based phase control, removing the board-level analog tuning stage. GTX transceiver phase alignment and manual byte-alignment fixing reduce restart uncertainty from 88.8~ps to 12~ps peak-to-peak. For multi-node operation, we introduce a cascaded global-control architecture with PC-side PID auto-tuned by TD3 reinforcement learning, on-chip-temperature feed-forward calibrated to $-0.76\,\mathrm{ps}/^\circ\mathrm{C}$. The measured point-to-point synchronization precision is 3.38~ps over 1~m fiber and 3.92~ps over 50~km. In a 12-level cascade, the end-node precision reaches 6.66~ps at constant temperature and 7.30~ps under a 13$\,^\circ$C temperature swing. Synchronized-clock TIE jitter stays below 1~ps regardless of cascade depth. Restart uncertainty is 2.82~ps (std.\ dev.). A 4-level cascade operated stably for 25 hours of continuous monitoring. All measured metrics fall well within the CEPC 30~ps budget.

hep-ex

Embedded underwater front-end electronics for the 3-inch photomultipliers in the JUNO experiment

The Jiangmen Underground Neutrino Observatory (JUNO) is a 20-kton liquid scintillator-based, low-radioactivity, multi-purpose neutrino detector located 693 meters (1800 m.w.e.) underground in the Guangdong province, China. To detect scintillation light produced in the target, the detector is equipped with 17,612 20-inch photomultipliers (PMTs), forming the Large PMT system (LPMT). In addition, 25,600 3-inch photomultipliers (the Small Photomultiplier System or SPMT) are deployed in the gaps between the LPMTs. This paper presents the design and performance of the underwater front-end electronics developed for the SPMT system. It details the individual electronics boards and their key components, the inter-board interfaces, the system-level design, and the firmware architecture that supports data acquisition and control. It also outlines mechanical and thermal integration, board validation procedures, and system performance metrics. The readout chain includes digitization of 128 PMT channels per unit, synchronized time-stamping, charge measurement, event packaging, and bandwidth management. Comprehensive validation confirms the system's readiness to meet JUNO's stringent physics goals. The underwater electronics achieve noise levels as low as 0.04 photoelectrons with minimal crosstalk (below 0.4%) and a bandwidth of 57 MB/s, ensuring reliable single photo-electron detection and operation under high-rate conditions. The SPMT system has now been fully integrated and installed in JUNO. Its commissioning and physics performance will be reported in a future publication.

physics.ins-det

First experimental proof of PET imaging based on multi-anode MCP-PMTs with Cherenkov radiator-integrated window

Improving the coincidence time resolution (CTR) of time-of-flight positron emission tomography (TOF-PET) systems to achieve a higher signal-to-noise ratio (SNR) gain or even direct positron emission imaging (dPEI) is of paramount importance for many advanced new clinical applications of PET imaging. This places higher demands on the timing performance of all aspects of PET systems. One effective approach is to use microchannel plate photomultiplier tubes (MCP-PMTs) for prompt Cherenkov photon detection. In this study, we developed a dual-module Cherenkov PET imaging experimental platform, utilising our proprietary 8 * 8-anode Cherenkov radiator-integrated window MCP-PMTs in combination with custom-designed multi-channel electronics, and designed a specific calibration and correction method for the platform. Using this platform, a CTR of 103 ps FWHM was achieved. We overcame the limitations of single-anode detectors in previous experiments, significantly enhanced imaging efficiency and achieved module-level Cherenkov PET imaging for the first time. Imaging experiments involving radioactive sources and phantoms of various shapes and types were conducted, which preliminarily validated the feasibility and advancement of this imaging method. In addition, the effects of normalisation correction and the interaction probability between the gamma rays and the MCP on the images and experimental results were analysed and verified.

physics.ins-det

JUNO 20-inch PMT and electronics system characterization using large pulses of PMT dark counts at the Pan-Asia testing platform

The main goal of the JUNO experiment is to determine the neutrino mass ordering with a 20kt liquid-scintillator detector. The 20-inch PMT and its 1F3 (one for three) electronics are crucial to realize the excellent energy resolution of at least 3% at 1MeV. The knowledge on the PMT and 1F3 electronics response is critical for detector performance understanding. A study of the JUNO 20-inch PMT and 1F3 electronics system characterization is presented using large pulses of PMT dark count at the Pan-Asia testing platform in China. Thanks to its broad amplitude range and high rate, the large pulse signals are also used to investigate the PMT after pulse response.

physics.ins-det

The High Voltage Splitter board for the JUNO SPMT system

The Jiangmen Underground Neutrino Observatory (JUNO) in southern China is designed to study neutrinos from nuclear reactors and natural sources to address fundamental questions in neutrino physics. Achieving its goals requires continuous operation over a 20-year period. The small photomultiplier tube (small PMT or SPMT) system is a subsystem within the experiment composed of 25600 3-inch PMTs and their associated readout electronics. The High Voltage Splitter (HVS) is the first board on the readout chain of the SPMT system and services the PMTs by providing high voltage for biasing and by decoupling the generated physics signal from the high-voltage bias for readout, which is then fed to the front-end board. The necessity to handle high voltage, manage a large channel count, and operate stably for 20 years imposes significant constraints on the physical design of the HVS. This paper serves as a comprehensive documentation of the HVS board: its role in the SPMT readout system, the challenges in its design, performance and reliability metrics, and the methods employed for production and quality control.

physics.ins-det

A 64-Channel Precision Time-to-Digital Converter with Average 4.77 ps RMS Implemented in a 28 nm FPGA

We have developed a Time-to-Digital Converter (TDC) application in a Xilinx Kintex-7 Field Programmable Gate Array (FPGA). This TDC, based on the Tapped-Delay Line (TDL) and Wave Union A (WU-A) techniques, achieves an independent time measurement on 32-channel rising edges and 32-channel falling edges. The average time resolution or the Least Significant Bit (LSB) of the 64 channels is measured to be 3 ps level, with an average root mean square (RMS) precision of 4.77 ps, and a maximum RMS below 8 ps. We also propose an online processing scheme that handles the bubble issues caused by clock region skew.

physics.ins-det

Performance studies of a SiPM-readout system with a pico-second timing chip

A pico-second timing (PIST) front-end electronic chip has been developed using $55~\mathrm{nm}$ CMOS technology for future electron-positron collider experiments (namely Higgs factories). Extensive tests have been performed to evaluate the timing performance of a dedicated SiPM-readout system equipped with a PIST chip. The results show that the system timing resolution can achieve $45~\mathrm{ps}$ for SiPM signals at the minimum-ionizing particles (MIP) level ($200~\mathrm{p.e.}$) and better than $ 10~\mathrm{ps}$ for signals larger than $1200~\mathrm{p.e.}$, while the PIST intrinsic timing resolution is $4.76 \pm 0.60~\mathrm{ps}$. The PIST dynamic range has been further extended using the time-over-threshold (ToT) technique, which can cover the SiPM response spanning from $\mathrm{\sim 900~p.e.}$ to $~\mathrm{\sim 40000~p.e.}$.

physics.ins-det

Implementation and performances of the IPbus protocol for the JUNO Large-PMT readout electronics

The Jiangmen Underground Neutrino Observatory (JUNO) is a large neutrino detector currently under construction in China. Thanks to the tight requirements on its optical and radio-purity properties, it will be able to perform leading measurements detecting terrestrial and astrophysical neutrinos in a wide energy range from tens of keV to hundreds of MeV. A key requirement for the success of the experiment is an unprecedented 3% energy resolution, guaranteed by its large active mass (20 kton) and the use of more than 20,000 20-inch photo-multiplier tubes (PMTs) acquired by high-speed, high-resolution sampling electronics located very close to the PMTs. As the Front-End and Read-Out electronics is expected to continuously run underwater for 30 years, a reliable readout acquisition system capable of handling the timestamped data stream coming from the Large-PMTs and permitting to simultaneously monitor and operate remotely the inaccessible electronics had to be developed. In this contribution, the firmware and hardware implementation of the IPbus based readout protocol will be presented, together with the performances measured on final modules during the mass production of the electronics.

physics.ins-det

Mass testing of the JUNO experiment 20-inch PMTs readout electronics

The Jiangmen Underground Neutrino Observatory (JUNO) is a multi-purpose, large size, liquid scintillator experiment under construction in China. JUNO will perform leading measurements detecting neutrinos from different sources (reactor, terrestrial and astrophysical neutrinos) covering a wide energy range (from 200 keV to several GeV). This paper focuses on the design and development of a test protocol for the 20-inch PMT underwater readout electronics, performed in parallel to the mass production line. In a time period of about ten months, a total number of 6950 electronic boards were tested with an acceptance yield of 99.1%.

physics.ins-det

Validation and integration tests of the JUNO 20-inch PMTs readout electronics

The Jiangmen Underground Neutrino Observatory (JUNO) is a large neutrino detector currently under construction in China. JUNO will be able to study the neutrino mass ordering and to perform leading measurements detecting terrestrial and astrophysical neutrinos in a wide energy range, spanning from 200 keV to several GeV. Given the ambitious physics goals of JUNO, the electronic system has to meet specific tight requirements, and a thorough characterization is required. The present paper describes the tests performed on the readout modules to measure their performances.

physics.ins-det

Check on the features of potted 20-inch PMTs with 1F3 electronics prototype at Pan-Asia

The Jiangmen underground neutrino observatory (JUNO) is a neutrino project with a 20-kton liquid scintillator detector located at 700-m underground. The large 20-inch PMTs are one of the crucial components of the JUNO experiment aiming to precision neutrino measurements with better than 3% energy resolution at 1 MeV. The excellent energy resolution and a large fiducial volume provide many exciting opportunities for addressing important topics in neutrino and astro-particle physics. With the container #D at JUNO Pan-Asia PMT testing and potting station, the features of waterproof potted 20-inch PMTs were measured with JUNO 1F3 electronics prototype in waveform and charge, which are valuable for better understanding on the performance of the waterproof potted PMTs and the JUNO 1F3 electronics. In this paper, basic features of JUNO 1F3 electronics prototype run at Pan-Asia will be introduced, followed by an analysis of the waterproof potted 20-inch PMTs and a comparison with the results from commercial electronics used by the container #A and #B.

physics.ins-det

Calibration Strategy of the JUNO-TAO Experiment

The Taishan Antineutrino Observatory (JUNO-TAO, or TAO) is a satellite detector for the Jiangmen Underground Neutrino Observatory (JUNO). Located near the Taishan reactor, TAO independently measures the reactor's antineutrino energy spectrum with unprecedented energy resolution. To achieve this goal, energy response must be well calibrated. Using the Automated Calibration Unit (ACU) and the Cable Loop System (CLS) of TAO, multiple radioactive sources are deployed to various positions in the detector to perform a precise calibration of energy response. The non-linear energy response can be controlled within 0.6% with different energy points of these radioactive sources. It can be further improved by using $^{12}\rm B$ decay signals produced by cosmic muons. Through the energy non-uniformity calibration, residual non-uniformity is less than 0.2%. The energy resolution degradation and energy bias caused by the residual non-uniformity can be controlled within 0.05% and 0.3%, respectively. In addition, the stability of other detector parameters, such as the gain of each silicon photo-multiplier, can be monitored with a special ultraviolet LED calibration system.

physics.ins-det

The MicroTCA fast control board for generic control and data acquisition applications in HEP experiments

To provide the generic clock, trigger and control function and fulfill the data transmission performance requirement in high energy physics (HEP) experiments, a MicroTCA Fast Control board (uFC) was developed based on the Advanced Mezzanine Card (AMC) specification. Built around the Xilinx Kintex-7 FPGA, the uFC provides users with a platform with data memory, reference clock, trigger and SFP+ (Small Form-factor Pluggable) connections that are required in general experiment. In addition, it has access to two on-board FPGA Mezzanine Card (FMC) sockets with a large array of configurable I/O and high-speed links up to 10 Gbps. This paper presents test results from the first set of pre-production prototypes and reports on the application in High Energy Photon Source in China.

physics.ins-det

A readout method based on 10 Gigabit Ethernet for Sipixel detector

With the rapid development of network protocol, TCP/IP has been widely applied in various OS systems because of its advantages of high-speed network transmission and standardization. Furthermore, TCP/IP has the functions of retransmission and flow control, so it can ensure data's security and stability. In recent years, as a transmission Field-bus, it is also widely used in high-energy physics detectors. This article describes a readout method using 10 gigabit network processor applied in silicon pixel detector which is a pixel detector designed for the High Energy Photon Source (HEPS) in China. The PHY layer and the MAC layer of this hardware are both instantiated in FPGA. The logic of hardware can process and read out the data of the detectors. Meanwhile, it wraps up data and send them to TOE (TCP Offload Engine). A kind of bus control protocol interface is also provided, which can facilitate the host computer to read and write the specific register directly through the UDP protocol. Only a piece of FPGA can complete the processing of the TCP and UDP packets. It is important for the miniaturization of the detectors.

cs.NI

First results of the new endcap TOF commissioning at BESIII

The upgrade of the current BESIII Endcap TOF (ETOF) is carried out with the Multi-gap Resistive Plate Chamber (MRPC) technology. The installation of the new ETOF has been finished in October 2015. The first results of the MRPCs commissioning at BESIII are reported in this paper.

physics.ins-det

The cosmic ray test of MRPCs for the BESIII ETOF upgrade

In order to improve the particle identification capability of the Beijing Spectrometer III (BESIII),t is proposed to upgrade the current endcap time-of-flight (ETOF) detector with multi-gap resistive plate chamber (MRPC) technology. Aiming at extending ETOF overall time resolution better than 100ps, the whole system including MRPC detectors, new-designed Front End Electronics (FEE), CLOCK module, fast control boards and time to digital modules (TDIG), was built up and operated online 3 months under the cosmic ray. The main purposes of cosmic ray test are checking the detectors' construction quality, testing the joint operation of all instruments and guaranteeing the performance of the system. The results imply MRPC time resolution better than 100$ps$, efficiency is about 98$\%$ and the noise rate of strip is lower than 1$Hz/$($scm^{2}$) at normal threshold range, the details are discussed and analyzed specifically in this paper. The test indicates that the whole ETOF system would work well and satisfy the requirements of upgrade.

physics.ins-det