Validation and integration tests of the JUNO 20-inch PMTs readout electronics

Abstract

The Jiangmen Underground Neutrino Observatory (JUNO) is a large neutrino detector currently under construction in China. JUNO will be able to study the neutrino mass ordering and to perform leading measurements detecting terrestrial and astrophysical neutrinos in a wide energy range, spanning from 200 keV to several GeV. Given the ambitious physics goals of JUNO, the electronic system has to meet specific tight requirements, and a thorough characterization is required. The present paper describes the tests performed on the readout modules to measure their performances.

Explore related subjects

Keep this discovery

BibTeXRIS

Vanessa Cerrone, Katharina von Sturm, Marco Bellato, Antonio Bergnoli, Matteo Bolognesi, Riccardo Brugnera, Chao Chen, Barbara Clerbaux, Alberto Coppi, Flavio dal Corso, Daniele Corti, Jianmeng Dong, Wei Dou, Lei Fan, Alberto Garfagnini, Guanghua Gong, Marco Grassi, Shuang Hang, Rosa Maria Guizzetti, Cong He, Jun Hu, Roberto Isocrate, Beatrice Jelmini, Xiaolu Ji, Xiaoshan Jiang, Fei Li, Zehong Liang, Ivano Lippi, Hongbang Liu, Hongbin Liu, Shenghui Liu, Xuewei Liu, Daibin Luo, Ronghua Luo, Filippo Marini, Daniele Mazzaro, Luciano Modenese, Zhe Ning, Yu Peng, Pierre-Alexandre Petitjean, Alberto Pitacco, Mengyao Qi, Loris Ramina, Mirco Rampazzo, Massimo Rebeschini, Mariia Redchuk, Andrea Serafini, Yunhua Sun, Andrea Triossi, Riccardo Triozzi, Fabio Veronese, Peiliang Wang, Peng Wang, Yangfu Wang, Yusheng Wang, Yuyi Wang, Zheng Wang, Ping Wei, Jun Weng, Shishen Xian, Xiaochuan Xie, Benda Xu, Chuang Xu, Donglian Xu, Hai Xu, Xiongbo Yan, Ziyue Yan, Fengfan Yang, Yan Yang, Yifan Yang, Mei Ye, Tingxuan Zeng, Shuihan Zhang, Wei Zhang, Aiqiang Zhang, Bin Zhang, Siyao Zhao, Changge Zi, Sebastiano Aiello, Giuseppe Andronico, Vito Antonelli, Andrea Barresi, Davide Basilico, Marco Beretta, Augusto Brigatti, Riccardo Bruno, Antonio Budano, Barbara Caccianiga, Antonio Cammi, Stefano Campese, Davide Chiesa, Catia Clementi, Marco Cordelli, Stefano Dusini, Andrea Fabbri, Giulietto Felici, Federico Ferraro, Marco G. Giammarchi, Cecilia Landini, Paolo Lombardi. 2022-12-16. Validation and integration tests of the JUNO 20-inch PMTs readout electronics. https://doi.org/10.1016/j.nima.2023.168322

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det