Conceptual Design Report for the MATHUSLA Long-Lived Particle Detector near CMS

Abstract

We present the Conceptual Design Report (CDR) for the MATHUSLA (MAssive Timing Hodoscope for Ultra-Stable neutraL pArticles) long-lived particle detector at the HL-LHC, covering the design, fabrication and installation at CERN Point 5. MATHUSLA is a 40 m-scale detector with an air-filled decay volume that is instrumented with scintillator tracking detectors, to be located near CMS. Its large size, close proximity to the CMS interaction point and about 100 m of rock shielding from HL-LHC backgrounds allows it to detect LLP production rates and lifetimes that are one to two orders of magnitude beyond the ultimate sensitivity of the HL-LHC main detectors for many highly motivated LLP signals. Data taking is projected to commence with the start of HL-LHC operations. We present a new 40m design for the detector: its individual scintillator bars and wavelength-shifting fibers, their organization into tracking layers, tracking modules, tower modules and the veto detector; define a high-level design for the supporting electronics, DAQ and trigger system, including supplying a hardware trigger signal to CMS to record the LLP production event; outline computing systems, civil engineering and safety considerations; and present preliminary cost estimates and timelines for the project. We also conduct detailed simulation studies of the important cosmic ray and HL-LHC muon backgrounds, implementing full track/vertex reconstruction and background rejection, to ultimately demonstrate high signal efficiency and $\ll 1$ background event in realistic LLP searches for the main physics targets at MATHUSLA. This sensitivity is robust with respect to detector design or background simulation details. Appendices provide various supplemental information.

Explore related subjects

Keep this discovery

BibTeXRIS

Branden Aitken, Cristiano Alpigiani, Juan Carlos Arteaga-Velázquez, Mitchel Baker, Kincso Balazs, Jared Barron, Brian Batell, Austin Batz, Yan Benhammou, Tamara Alice Bud, Karen Salomé Caballero-Mora, John Paul Chou, David Curtin, Albert de Roeck, Miriam Diamond, Mariia Didenko, Keith R. Dienes, William Dougherty, Liam Andrew Dougherty, Marco Drewes, Sameer Erramilli, Erez Etzion, Arturo Fernández Téllez, Grace Finlayson, Oliver Fischer, Jim Freeman, Jonathan Gall, Ali Garabaglu, Bhawna Gomber, Stephen Elliott Greenberg, Jaipratap Singh Grewal, Zoe Hallman, Bahgat Hassan, Yuekun Heng, Keegan Humphrey, Trystan Humphrey, Graham D. Kribs, Alex Lau, Jiahao Liao, Zhen Liu, Giovanni Marsella, Matthew McCullough, David McKeen, Patrick Meade, Caleb Miller, Gilad Mizrachi, O. G. Morales-Olivares, David Morrissey, Abdulrahman Ahmed Morsy, John Osborn, Gabriel Owh, Michalis Panagiotou, Mason Proffitt, Runze Ren, Steven H. Robertson, Mario Rodríguez-Cahuantzi, Heather Russell, Victoria Sánchez, Halil Saka, Mamoksh Samra, Rodney Schnarr, Jessie Shelton, Yiftah Silver, Daniel Stolarski, Martin A. Subieta Vasquez, Sanjay Kumar Swain, Steffie Ann Thayil, Brooks Thomas, Emma Torro, Yuhsin Tsai, Bennett Winnicky-Lewis, Igor Zolkin, Jose Zurita. 2025-03-26. Conceptual Design Report for the MATHUSLA Long-Lived Particle Detector near CMS. https://arxiv.org/abs/2503.20893

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det