SearcharxivSearch

arXiv · 2511.18693

Development of a dual-phase xenon time projection chamber prototype for the RELICS experiment

Abstract

The RELICS (REactor neutrino LIquid xenon Coherent elastic Scattering) experiment aims to detect coherent elastic neutrino-nucleus scattering from reactor antineutrinos using a dual-phase xenon time projection chamber. To validate the detector concept and ensure technical reliability for the full-scale experiment, a dedicated prototype was designed, constructed, and operated. This work presents an overview of the design, construction, and operational performance of the prototype, with emphasis on its major subsystems, including the TPC, cryogenic and xenon purification systems, slow control, and data acquisition. During operation, the detector demonstrated the capability to achieve a sub-keV energy threshold required for the RELICS physics program, as reflected by a measured single electron gain of 34.30~$\pm$~0.01~(stat.)~PE/e$^-$ and the successful detection of 0.27~keV L-shell decay events from $^{37}$Ar. In addition, essential data analysis techniques and simulation frameworks were developed and validated, establishing the methodological foundation for future RELICS operations. The successful construction and operation of this prototype confirm the feasibility of the core technologies and provide a crucial experimental basis for the final RELICS detector.

Explore related subjects

Keep this discovery

BibTeXRIS

Lingfeng Xie, Jiajun Liu, Yifei Zhao, Chang Cai, Guocai Chen, Jiangyu Chen, Huayu Dai, Rundong Fang, Hongrui Gao, Fei Gao, Jingfan Gu, Xiaoran Guo, Jiheng Guo, Chengjie Jia, Gaojun Jin, Fali Ju, Yanzhou Hao, Xu Han, Yang Lei, Kaihang Li, Meng Li, Minhua Li, Ruize Li, Shengchao Li, Siyin Li, Tao Li, Qing Lin, Sheng Lv, Guang Luo, Yuanyuan Ren, Chuanping Shen, Mingzhuo Song, Lijun Tong, Yuhuang Wan, Xiaoyu Wang, Wei Wang, Xiaoping Wang, Zihu Wang, Yuehuan Wei, Liming Weng, Xiang Xiao, Yikai Xu, Jijun Yang, Litao Yang, Long Yang, Jingqiang Ye, Jiachen Yu, Qian Yue, Yuyong Yue, Tianyuan Zha, Bingwei Zhang, Yuming Zhang, Chenhui Zhu. 2025-11-24. Development of a dual-phase xenon time projection chamber prototype for the RELICS experiment. https://doi.org/10.1140/s10052-026-15529-y

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det