SearcharxivSearch

arXiv · 2511.22308

Timing resolution from beam tests on thin LGADs down to 16.6 ps

Abstract

The paper reports on the timing resolution achieved with Low-Gain Avalanche Diodes (LGADs), optimised for extreme-fluence conditions, at the DESY Test Beam Facility using 4~GeV/c electrons. The LGADs adopt an $n$-in-$p$ technology with a $p^{+}$-type boron gain implant, co-implanted with carbon to mitigate acceptor deactivation due to irradiation. The substrate thickness of the sensors varies from 20 to 45~\micron, with an active area spanning from 0.75~$\times$~0.75 to 1.28~$\times$~1.28~mm$^{2}$. The experimental setup consisted of a 45~\micron-thick trigger sensor with an active area of 3.6~$\times$~3.6~mm$^{2}$, two device-under-test (DUT) planes, and a Photonis micro-channel plate photomultiplier tube (MCP) as a time reference. Data taking was performed at the ambient temperature of the facility, at 18$^{\circ}$C. The gain was measured between 7 and 40 across all non-irradiated sensors in the study. The timing resolution was calculated from a Gaussian fitting of the difference in times of arrival of a particle at the DUT and the MCP, using the constant fraction discriminator technique. A timing resolution of 26.4~\ps was achieved in 45~\micron-thick sensors, down to 16.6~\ps in 20~\micron-thick sensors, in the non-irradiation study. The combination of two 20~\micron-thick LGADs reached a timing resolution of 12.2~\ps. A set of 30~\micron-thick sensors irradiated with neutrons at fluences between 0.4~$\times$~10$^{15}$ and 2.5~$\times$~10$^{15}$~\mevneut were tested in the beam. These irradiated sensors achieved a gain between 7 and 30 using a similar apparatus but cooled with solidified CO$_{2}$ to -42$^{\circ}$C. A timing resolution of 20~\ps was obtained in these irradiated sensors.

Explore related subjects

Keep this discovery

BibTeXRIS

Robert Stephen White, Marco Ferrero, Valentina Sola, Anna Rita Altamura, Roberta Arcidiacono, Maurizio Boscardin, Nicolo Cartglia, Matteo Centis Vignali, Tommaso Croci, Matteo Durando, Simone Galletto, Alessandro Fondacci, Leonardo Lanteri, Luca Menzio, Francesco Moscatelli, Giovanni Paternoster, Federico Siviero. 2025-11-27. Timing resolution from beam tests on thin LGADs down to 16.6 ps. https://doi.org/10.1016/j.nima.2026.171596

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det