Searcharxiv⌕ Search

arXiv · 2609.35850

Quantitative characterization of superconducting qubits as particle detectors

Abstract

Ionizing radiation is a major source of correlated errors in superconducting quantum processors, yet the mechanisms responsible for the qubit response to particle interactions remain only partially understood. In this work, we operate superconducting qubits as particle detectors while simultaneously monitoring the deposited energy with an independent semiconductor cryogenic sensor. This complementary measurement provides an absolute determination of the particle interaction rate in the chip, enabling the first direct measurement of the detection efficiency of superconducting qubits exposed to environmental radiation. We measure individual qubit detection efficiencies of about 30-40$\%$, increasing to approximately 50$\%$ when combining the response of two qubits. Under the conservative assumption that the efficiency loss is entirely determined by a finite detection threshold, we derive an upper limit on the effective energy threshold of the detector of $70\pm20~\mathrm{(stat)}\pm30~\mathrm{(syst)}~\mathrm{keV}$. Measurements with radioactive sources producing different deposited-energy spectra further show that the detection efficiency decreases for lower-energy interactions. We further investigate the origin of the qubit response by injecting controlled thermal pulses with a resistive heater. Although these pulses deposit energies comparable to those released by particle interactions, they do not reproduce the radiation-induced signatures, demonstrating that the qubit response to radiation cannot be explained by a transient increase in substrate temperature alone. Our results establish an experimental framework for quantitatively connecting particle energy deposition to radiation-induced responses in superconducting quantum circuits.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Francesco De Dominicis, Raja Yasir Mehmood Khan, Dounia L Helis, Ambra Mariani, Letizia Tirabasso, Alberto Ressa, Mustafa Bal, Fabio Bellini, Camilla Bonomo, Nicola Casali, Gianluigi Catelani, Ivan Colantoni, Francesco Crisa, Angelo Cruciani, Sabrina Garattoni, Luca Gironi, Andrea Melchiorre, Lorenzo Pagnanini, Valerio Pettinacci, Stefano Pirro, Andrei Puiu, Tanay Roy, Shaojiang Zhu, Anna Grassellino, Laura Cardani. 2026-09-25. Quantitative characterization of superconducting qubits as particle detectors. https://arxiv.org/abs/2609.35850

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Projection of purification performance for the RELICS experiment

The RELICS (REactor neutrino LIquid xenon Coherent elastic Scattering) experiment employs a dual-phase liquid xenon time projection chamber to search for Coherent Elastic Neutrino-Nucleus Scattering (CE$ν$NS) induced by reactor neutrinos. To detect these sub-keV nuclear recoils and minimize signal attenuation, it is critical to maintain a sufficiently low impurity concentration in the detector. This work presents a comprehensive purity evolution model developed to describe impurity migration inside the detector. Utilizing measured material outgassing rates as input parameters, the model incorporates non-uniform transport mechanisms of the impurities, including circulation, vaporization, and condensation. The model is validated using data from a dedicated prototype detector. Based on this validated model, projections for the purification performance of the upcoming RELICS-10 and RELICS-50 detectors are provided.

physics.ins-det↗

Energy, time, and position resolution measurements of an array of large tapered LYSO crystals

We report on the performance of six custom-made tapered LYSO crystals of unprecedented volume, which constitute a sector of the 19 radiation length electromagnetic calorimeter planned for the PIONEER experiment. The longitudinal response uniformity of each crystal was measured using radioactive sources before characterizing the energy and time resolution of the crystals in an array using a 20 to 80 MeV positron beam at the Paul Scherrer Institute. The array demonstrated an energy resolution better than 2 % for energies above 40 MeV and a time resolution better than 140 ps for energies above 30 MeV. The spatial resolution was measured in the central region of the array to be 5.06 mm in x and 5.20 mm in y at 70 MeV. The measured properties satisfy the key design parameters of the PIONEER calorimeter for the measurement of rare pion decays.

physics.ins-det↗

Investigating Optical Coupling Material Candidates in NaI(Tl) Detectors for the SABRE-North Dark Matter Experiment

Direct dark matter detection with NaI(Tl) scintillators requires ultra-low-background materials. Silicone optical pads can couple NaI(Tl) crystals to photomultiplier tubes (PMTs) if they provide adequate optical transmission and radiopurity. We characterize four candidate materials for the SABRE-North experiment: commercial EJ-560, used as a reference, and three materials produced at the University of Salento (SYLGARD 184, EGel 3002 A/B, and a hybrid formulation) using different catalyst ratios and curing conditions, yielding ten samples in total. Optical transmittance was measured from 310 to 850 nm by UV/Vis/NIR spectrophotometry. Radiopurity was assessed at the STELLA facility at LNGS using high-purity germanium (HPGe) $γ$-ray spectrometry and, for EJ-560, high-resolution ICP-MS. At the 410 nm NaI(Tl) emission peak, EJ-560 shows an absorbance coefficient of $0.064\pm0.017$ mm$^{-1}$. The best locally produced samples reach $0.097\pm0.015$ and $0.093\pm0.014$ mm$^{-1}$ for SYLGARD 184 with a 10:2 base-to-catalyst ratio cured at room temperature and at $40^\circ$C, respectively, $0.125\pm0.015$ mm$^{-1}$ for EGel 3002 with a 2B:A ratio cured at $40^\circ$C, and $0.106\pm0.014$ mm$^{-1}$ for the hybrid 10:1 EGel A:CataSYL formulation cured at room temperature. EJ-560 exhibits detectable $^{232}$Th-chain activity at about 1.8 mBq/kg and the highest $^{40}$K activity, $(120\pm20)$ mBq/kg. The locally produced materials show no detectable Th-chain contamination but exhibit $^{226}$Ra activities of about 2.3 mBq/kg and lower $^{40}$K levels. No single material is optimal across all criteria. Additional ICP-MS screening, HPGe measurements of cured pads, and direct NaI(Tl)-PMT light-yield tests are required for a conclusive SABRE-North material selection.

physics.ins-det↗