Searcharxiv⌕ Search

arXiv · 2610.22418

Long-Lived Charge Trap Characterization for Rare-Event Searches with Skipper-CCDs

Abstract

Skipper Charge-Coupled Devices (Skipper-CCDs) are detectors with sub-electron resolution, allowing them to play a critical role in rare-event searches. A major challenge in experiments using these detectors is understanding and mitigating low-energy backgrounds which impact the single-electron rate. One potential component of the single-electron rate could arise from single-electron charge traps caused by lattice defects. In this work we use a new in-situ technique for generating uniform charge known as ``pixel-pumping'' across the CCD to study single-electron traps in a SENSEI sensor placed underground in the MINOS cavern at Fermilab, which enables sensitivity to long-lived traps with emission times $>10^3$ seconds, a regime that was previously not accessible. We fully characterize 1787 traps and use this information to estimate their contribution to the single-electron background in SENSEI. Through simulation, we find the characterized population of traps does not significantly impact the single-electron rate. We further identify the energies and cross-sections for traps to which this analysis is sensitive, and compare this with the values that could impact the single-electron rate. This analysis probes a large fraction of this region. However, we also see that a sufficiently numerous hidden population could contribute significantly to the single-electron rate, and new measurement techniques will have to be devised in order to fully rule out this population.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ansh Desai, Ana M. Botti, Brenda A. Cervantes-Vergara, Rouven Essig, Stephen E. Holland, Ian Lawson, Steffon Luoma, Santiago Perez, Javier Tiffenberg, Sho Uemura, Yikai Wu, Tien-Tien Yu. 2026-10-15. Long-Lived Charge Trap Characterization for Rare-Event Searches with Skipper-CCDs. https://arxiv.org/abs/2610.22418

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Positron Emission Tomography with quantum-entangled Compton events: first imaging results at clinically relevant activities

In Positron Emission Tomography, a potential, yet unutilized enhancement, may come from exploiting the quantum entanglement of the annihilation quanta, inscribed in the correlation of their polarizations. To investigate this, we built a PET demonstrator capable of measuring polarization correlations of annihilation quanta by their Compton scattering, based on single-layer scintillator polarimeters. We present a detailed study of the imaging of two $^{68}$Ge line sources, 45 MBq each, to extract the spatial resolution and assess image quality. The results show that a spatial resolution of 2.5$\pm$0.1 mm is obtained using single-pixel events, while resolutions obtained with polarization-correlated Compton events range from 3.6$\pm$0.3 mm to 4.9$\pm$0.3 mm, depending on data selection criteria. We also found that the polarization-correlated Compton events exhibit up to 20% higher average signal to random background ratio compared to the single-pixel events. We also present the first imaging of the NEMA NU-4 phantom filled with a $^{68}$Ga solution of 378 MBq initial activity, successfully combining polarization-correlated events with conventional single-pixel event selection. Based on the extracted spatial resolution, signal-to-background, signal-to-noise, contrast, and contrast-to-noise ratio, we estimate that up to 10% sensitivity increase may be attained by exploiting the polarization-correlated events, while preserving a high image quality.

physics.ins-det↗

Characterization of immersed SiPM arrays in liquid scintillator between room temperature and $-30\,^{\circ}\mathrm{C}$

Liquid scintillator detectors instrumented with distributed silicon photomultiplier (SiPM) arrays can be used in compact, topology-sensitive, and low-background experiments, but the temperature dependence of SiPMs immersed directly in the scintillation medium has not been widely characterized. We report the operation of a 125-liter linear-alkylbenzene-based liquid scintillator detector read out by 125 SiPM channels immersed in the active volume, over the range from room temperature to $-30\,^{\circ}\mathrm{C}$. The detector response was measured with cosmic-ray muons, including stopping muons followed by their Michel-electron decay. Cooling from $+15\,^{\circ}\mathrm{C}$ to $-30\,^{\circ}\mathrm{C}$ reduced the SiPM dark-count rate by a factor of 13.5, increased the single-photoelectron response by 49.1%, and increased the cosmic-ray muon light yield by 16.7%. The improved photoelectron separation and baseline stability at low temperature enabled a selection of stopping-muon events, from which the effective muon lifetime was measured to be $1959\pm132\,\mathrm{ns}$, consistent with the value expected for a hydrocarbon scintillator once $μ^{-}$ capture on carbon is taken into account.

physics.ins-det↗

Residual AM and PM Noise of Selected X-Band Amplifiers

In microwave systems design, amplitude modulation (AM) noise is often ignored relative to phase modulation (PM) noise. However, in high-performance applications requiring ultra-low PM noise, AM noise becomes a critical limiting factor due to AM-to-PM conversion mechanisms. Because AM noise specifications are rarely, if ever, provided for commercial microwave components, this study characterizes the residual AM and PM noise of several 10 GHz amplifiers. We present performance data for various Heterojunction Bipolar Transistor (HBT) amplifier designs and demonstrate the noise reduction achieved through power-summed configurations. For example, a discrete-die GaAs HBT amplifier achieves residual PM noise below $-160$ dBrad$^2$/Hz and AM noise of approximately $-155$ dB/Hz at a 1 kHz offset in a quad power-summed configuration. A notable finding is that the majority of amplifier designs surveyed in this study exhibit higher AM noise relative to their PM noise, with only a few exceptions. The impact of bias supply quality on residual noise is also quantified, demonstrating that the choice of voltage regulator is a first-order design parameter below 1 kHz offset.

physics.ins-det↗